English
Related papers

Related papers: Characterisation of an n-type segmented BEGe detec…

200 papers

The ability of background discrimination using pulse shape discrimination (PSD) in broad-energy germanium (BEGe) detectors makes them as competitive candidates for neutrinoless double beta decay (0{\nu}\b{eta}\b{eta}) experiments. The…

Instrumentation and Detectors · Physics 2016-06-28 Zhi Zeng , Yu-Hao Mi , Ming Zeng , Hao Ma , Qian Yue , Jian-Ping Cheng , Jun-Li Li , Rui Qiu , Hui Zhang

The performance of a 630g commercial broad energy germanium (BEGe) detector has been systematically investigated. Energy resolution, linearity, stability vs. high-voltage (HV) bias, thickness and uniformity of dead layers have been measured…

Instrumentation and Detectors · Physics 2015-03-17 M. Agostini , E. Bellotti , R. Brugnera , C. M. Cattadori , A. D'Andragora , A. di Vacri , A. Garfagnini , M. Laubenstein , L. Pandola , C. A. Ur

An electrically cooled Broad Energy Germanium (BEGe) detector has been characterized in the energy range E$_{\gamma}$ $\sim$ 0.122 - 7 MeV by utilizing the $\gamma$- rays emitted by a short-lived resonance state in $^{15}$O populated…

Instrumentation and Detectors · Physics 2020-04-22 Sathi Sharma , Arkabrata Gupta , Balaram Dey , M. Roy Chowdhury , A. Mandal , A. Bisoi , V. Nanal , L. C. Tribedi , M. Saha Sarkar

High Purity germanium point-contact detectors have low energy thresholds and excellent energy resolution over a wide energy range, and are thus widely used in nuclear and particle physics. In rare event searches, such as neutrinoless double…

Instrumentation and Detectors · Physics 2019-02-20 S. Mertens , A. Hegai , D. C. Radford , N. Abgrall , Y. -D. Chan , R. D. Martin , A. W. P. Poon , C. Schmitt

First studies of event discrimination with a Broad-Energy Germanium (BEGe) detector are presented. A novel pulse shape method, exploiting the characteristic electrical field distribution inside BEGe detectors, allows to identify efficiently…

Nuclear Experiment · Physics 2009-12-14 Dušan Budjáš , Marik Barnabé Heider , Oleg Chkvorets , Nikita Khanbekov , Stefan Schönert

A study of signals originating near the lithium-diffused n+ contact of p-type point contact (PPC) high purity germanium detectors (HPGe) is presented. The transition region between the active germanium and the fully dead layer of the n+…

We present data characterizing the performance of the first segmented, N-type Ge detector, isotopically enriched to 85% $^{76}$Ge. This detector, based on the Ortec PT6x2 design and referred to as SEGA (Segmented, Enriched Germanium…

In this work we present the characterization of a Broad Energy Germanium (BEGe) type High Purity Germanium (HPGe) detector, with a carbon fiber entrance window thickness of 0.6 mm and an active area of 6305 mm2, operated at shallow depth (~…

Instrumentation and Detectors · Physics 2023-10-20 O. Fawwaz , H. Shams , F. Arneodo , A. Di Giovanni

The first true coaxial 18-fold segmented n-type HPGe prototype detector produced by Canberra-France for the GERDA neutrinoless double beta-decay project was tested both at Canberra-France and at the Max-Planck-Institut fuer Physik in…

Nuclear Experiment · Physics 2008-11-26 I. Abt , A. Caldwell , D. Gutknecht , K. Kröninger , M. Lampert , X. Liu , B. Majorovits , D. Quirion , F. Stelzer , P. Wendling

Radiation detectors constructed from large volume high purity Ge (HPGe) single crystals are widely used for gamma-ray spectroscopy. The detectors for this application can be simple in that they need only have two electrical contacts for…

Instrumentation and Detectors · Physics 2020-06-11 Mark Amman

Large, high-purity, germanium (HPGe) detectors are needed for neutrinoless double-beta decay and dark matter experiments. Currently, large (> 4 inches in diameter) HPGe crystals can be grown at the University of South Dakota (USD). We…

Instrumentation and Detectors · Physics 2019-03-27 X. -H. Meng , G. -J. Wang , M. -D. Wagner , H. Mei , W. -Z. Wei , J. Liu , G. Yang , D. -M. Mei

The \textsc{Gerda} experiment searches for the neutrinoless double beta ($0\nu\beta$beta$) decay of $^{76}$Ge using high-purity germanium detectors made of material enriched in $^{76}$Ge. For Phase II of the experiment a sensitivity for the…

A new type of radiation detector, a p-type modified electrode germanium diode, is presented. The prototype displays, for the first time, a combination of features (mass, energy threshold and background expectation) required for a…

Nuclear Experiment · Physics 2011-05-12 P. S. Barbeau , J. I. Collar , O. Tench

A new technique of elucidating $\beta$-decay schemes of isotopes with large density of states at low excitation energies has been developed, in which a Broad Energy Germanium (BEGe) detector is used in conjunction with coaxial hyper-pure…

Experiments built to search for neutrinoless double beta-decay are limited in their sensitivity not only by the exposure but also by the amount of background encountered. Radioactive isotopes in the surrounding of the detectors which emit…

Nuclear Experiment · Physics 2008-11-26 I. Abt , A. Caldwell , K. Kröninger , J. Liu , X. Liu , B. Majorovits

High purity germanium (HPGe) crystals will be used for the MAJORANA DEMONSTRATOR, where they serve as both the source and the detector for neutrinoless double beta decay. It is crucial for the experiment to understand the performance of the…

The GERDA experiment searches for the neutrinoless double beta decay of Ge-76 using high-purity germanium detectors enriched in Ge-76. The analysis of the signal time structure provides a powerful tool to identify neutrinoless double beta…

Instrumentation and Detectors · Physics 2015-03-17 M. Agostini , C. A. Ur , D. Budjáš , E. Bellotti , R. Brugnera , C. M. Cattadori , A. di Vacri , A. Garfagnini , L. Pandola , S. Schönert

The GERmanium Detector Array, GERDA, is designed for the search for ``neutrinoless double beta decay'' (0-nu-2-beta) with germanium detectors enriched in Ge76. An 18-fold segmented prototype detector for GERDA Phase II was exposed to an…

Nuclear Experiment · Physics 2008-11-26 I. Abt , A. Caldwell , K. Kroeninger , J. Liu , X. Liu , B. Majorovits

Parity is a key observable in nuclear spectroscopy. Linear polarization measurements of $\gamma$-rays are a probe to access the parities of energy levels. Utilizing the segmentation of detectors in the Segmented Germanium Array (SeGA) at…

Nuclear Experiment · Physics 2009-09-29 D. Miller , A. Chester , V. Moeller , K. Starosta , C. Vaman , D. Weisshaar

The detection of low-energy deposition in the range of sub-eV through ionization using germanium (Ge) with a bandgap of $\sim$0.7 eV requires internal amplification of charge signal. This can be achieved through high electric field which…

Instrumentation and Detectors · Physics 2022-03-23 W. -Z. Wei , H. Mei , K. Kooi , D. -M. Mei , J. Liu , J. -C. Li , R. Panth , G. -J. Wang
‹ Prev 1 2 3 10 Next ›