Related papers: Quantum interferometry via a coherent state mixed …
A recently proposed phase-estimation protocol that is based on measuring the parity of a two-mode squeezed-vacuum state at the output of a Mach-Zehnder interferometer shows that Cram\'{e}r-Rao bound sensitivity can be obtained [P.\ M.\…
The interference between coherent and squeezed vacuum light can produce path entangled states with very high fidelities. We show that the phase sensitivity of the above interferometric scheme with parity detection saturates the quantum…
We study a Mach-Zehnder interferometer fed by a coherent state in one input port and vacuum in the other. We explore a Bayesian phase estimation strategy to demonstrate that it is possible to achieve the standard quantum limit independently…
A proposed phase-estimation protocol based on measuring the parity of a two-mode squeezed-vacuum state at the output of a Mach-Zehnder interferometer shows that the Cram\'{e}r-Rao sensitivity is sub-Heisenberg [Phys.\ Rev.\ Lett.\ {\bf104},…
In this letter, we show that for all the so-called path-symmetric states, the measurement of parity of photon number at the output of an optical interferometer achieves maximal phase sensitivity at the quantum Cramer-Rao bound. Such optimal…
We study the sensitivity and resolution of phase measurement in a Mach-Zehnder interferometer with two-mode squeezed vacuum (<n> photons on average). We show that super-resolution and sub-Heisenberg sensitivity is obtained with parity…
The research focused on enhancing the measurement accuracy through the use of non-Gaussian states has garnered increasing attention. In this study, we propose a scheme to input the coherent state mixed with photon-catalyzed squeezed vacuum…
We address in this work the phase sensitivity of a Mach-Zehnder interferometer with Gaussian input states. A squeezed-coherent plus squeezed vacuum input state allows us to unambiguously determine the optimal phase-matching conditions in…
We study the phase sensitivity in the conventional $SU(2)$ and nonconventional $SU(1,1)$ interferometers with the coherent and squeezed vacuum input state via the quantum Cramer-Rao bound. We explicitly construct the detection scheme that…
We quantitatively investigate phase measurement in a Mach-Zehnder interferometer (MZI), which is injected with a weak coherent and a squeezed vacuum generated from a spontaneous parametric down-conversion. The measured three-photon…
In this paper, we investigate the phase sensitivities in two-path optical interferometry with asymmetric beam splitters. Here, we present the optimal conditions for the transmission ratio and the phase of the beam splitter to gain the…
We find a large class of pure and mixed input states with which the phase estimation precision saturates the Cramer-Rao bound under the compound measurements of parity and particle number. We further propose a quantum-phase-estimation…
We theoretically investigate the phase sensitivity with parity detection on an SU(1,1) interferometer with a coherent state combined with a squeezed vacuum state. This interferometer is formed with two parametric amplifiers for beam…
Quantum Cramer-Rao (QCR) bound is attached to a particular nonclassical state, therefore appropriate choice of the probe state is of the key importance to enhance sensitivity beyond classical one. Since the work of C.M. Caves (Phys. Rev. D…
Mach-Zehnder interferometer is a common device in quantum phase estimation and the photon losses in it are an important issue for achieving a high phase accuracy. Here we thoroughly discuss the precision limit of the phase in the…
It is shown that the maximal phase sensitivity of a two-path interferometer with high-intensity coherent light and squeezed vacuum in the input ports can be achieved by photon-number-resolving detection of only a small number of photons in…
The canonical Mach-Zehnder interferometer fed with a coherent state and a squeezed-vacuum state of equal intensities is theoretically predicted to achieve Heisenberg scaling in phase sensitivity. However, this ultimate performance is…
We show that the phase sensitivity $\Delta \theta$ of a Mach-Zehnder interferometer fed by a coherent state in one input port and squeezed-vacuum in the other one is i) independent from the true value of the phase shift and ii) can reach…
Phase measurement using a lossless Mach-Zehnder interferometer with certain entangled $N$-photon states can lead to a phase sensitivity of the order of 1/N, the Heisenberg limit. However, previously considered output measurement schemes are…
Number state filtered coherent states are a class of nonclassical states obtained by removing one or more number states from a coherent state. Phase sensitivity of an interferometer is enhanced if these nonclassical states are used as input…