English
Related papers

Related papers: RPC performance vs FE electoronics and detector pa…

200 papers

Dedicated detector simulations are very important for the success of high energy physics experiments. They not only bring benefits to the optimization of the detectors, but can also improve the precision of the physics results. To design a…

Instrumentation and Detectors · Physics 2018-09-26 Fuyue Wang , Dong Han , Yi Wang , Yancheng Yu , Qiunan Zhang , Baohong Guo , Yuanjing Li

A novel design of Resistive Plate Chambers (RPCs), using only a single resistive plate, is being proposed. Based on this design, two large size prototype chambers were constructed and were tested with cosmic rays and in particle beams. The…

Instrumentation and Detectors · Physics 2015-05-20 B. Bilki , F. Corriveau , B. Freund , C. Neubüser , Y. Onel , J. Repond , J. Schlereth , L. Xia

This paper presents a streamlined framework for real-time processing and analysis of condition data from the CMS experiment Resistive Plate Chambers (RPC). Leveraging data streaming, it uncovers correlations between RPC performance metrics,…

High Energy Physics - Experiment · Physics 2025-04-15 A. Dimitrov , M. Tytgat , K. Mota Amarilo , A. Samalan , K. Skovpen , G. A. Alves , E. Alves Coelho , F. Marujo da Silva , M. Barroso Ferreira Filho , E. M. Da Costa , D. De Jesus Damiao , S. Fonseca De Souza , R. Gomes De Souza , L. Mundim , H. Nogima , J. P. Pinheiro , A. Santoro , M. Thiel , A. Aleksandrov , R. Hadjiiska , P. Iaydjiev , M. Shopova , G. Sultanov , L. Litov , B. Pavlov , P. Petkov , A. Petrov , E. Shumka , P. Cao , W. Diao , Q. Hou , H. Kou , Z. -A. Liu , J. Song , J. Zhao , S. J. Qian , C. Avila , D. A. Barbosa Trujillo , A. Cabrera , C. A. Florez , J. A. Reyes Vega , R. Aly , A. Radi , Y. Assran , I. Crotty , M. A. Mahmoud , M. Gouzevitch , G. Grenier , I. B. Laktineh , L. Mirabito , I. Bagaturia , I. Lomidze , Z. Tsamalaidze , V. Amoozegarp , B. Boghrati , M. Ebrahimi , F. Esfandi , Y. Hosseini , M. Mohammadi Najafabadi , E. Zareian , M. Abbrescia , N. De Filippis , G. Iaselli , F. Loddo , G. Pugliese , D. Ramos , L. Benussi , S. Bianco , S. Meola , D. Piccolo , S. Buontempo , F. Carnevali , F. Fienga , L. Lista , P. Paolucci , A. Braghieri , P. Montagna , C. Riccardi , P. Salvini , P. Vitulo , E. Asilar , T. J. Kim , Y. Ryou , S. Choi , B. Hong , K. S. Lee , J. Goh , J. Shin , Y. Lee , I. Pedraza , C. Uribe Estrada , H. Castilla-Valdez , R. Lopez-Fernandez , A. Sanchez Hernandez , M. Ramirez Garcia , D. L. Ramirez Guadarrama , M. A. Shah , E. Vazquez , N. Zaganidis , A. Ahmad , M. I. Asghar , H. R. Hoorani , S. Muhammad , J. Eysermans

For precise start time determination a Beam Fragmentation T$_0$ Counter (BFTC) is under development for the Time-of-Flight Wall of the Compressed Baryonic Matter Spectrometer (CBM) at the Facility for Antiproton and Ion Research (FAIR) at…

The innermost station of the present ATLAS forward muon detector needs to be upgraded for the super-LHC. We present a proposal to replace it with a sandwiched detector composed of several layers of small-radius Monitored Drift Tube chambers…

Instrumentation and Detectors · Physics 2012-10-26 Junjie Zhu

The Particle Flow Analysis approach retained for the future ILC detectors requires high granularity and compact particle energy deposition. A Glass Resistive Plate Chamber based Semi-Digital calorimeter can offer both at a low price for the…

Instrumentation and Detectors · Physics 2019-08-13 Vincent Boudry

Resistive Plate Counters (RPC) detectors at the Large Hadron Collider (LHC) experiments use gas recirculation systems to cope with large gas mixture volumes and costs. In this paper a long-term systematic study about gas purifiers, gas…

The Resistive Plate Chambers detector system at the CMS experiment at the LHC provides robustness and redundancy to the muon trigger. A total of 1056 double-gap chambers cover the pseudo-rapidity region < 1.6. The main detector parameters…

Instrumentation and Detectors · Physics 2016-05-31 Mehar Ali Shah

In the High Luminosity Large Hadron Collider (HL-LHC) program, during the next years, the instantaneous luminosity will increase up to 5 $\times$ 10$^{34}$ cm$^{-2}$ s$^{-1}$ which means a factor five higher than the nominal LHC. In that…

Instrumentation and Detectors · Physics 2021-11-30 R. Aly

We studied the effect of water vapor on the performance of glass Resistive Plate Chambers (RPCs) in the avalanche mode operation. Controlled and calibrated amount of water vapor was added to the RPC gas mixture that has C$_2$H$_2$F$_4$ as…

Instrumentation and Detectors · Physics 2016-08-24 K. Raveendrababu , P. K. Behera , B. Satyanarayana , S. Mukhopadhayay , N. Majumdar

We present recent results of an extensive aging test, performed at the CERN Gamma Irradiation Facility on two single--gap RPC prototypes, developed for the LHCb Muon System. With a method based on a model describing the behaviour of an RPC…

A large Time Projection Chamber is the main device for tracking and charged-particle identification in the ALICE experiment at the CERN LHC. After the second long shutdown in 2019/20, the LHC will deliver Pb beams colliding at an…

Instrumentation and Detectors · Physics 2018-07-16 M. M. Aggarwal , Z. Ahammed , S. Aiola , J. Alme , T. Alt , W. Amend , A. Andronic , V. Anguelov , H. Appelshäuser , M. Arslandok , R. Averbeck , M. Ball , G. G. Barnaföldi , E. Bartsch , R. Bellwied , G. Bencedi , M. Berger , N. Bialas , P. Bialas , L. Bianchi , S. Biswas , L. Boldizsár , L. Bratrud , P. Braun-Munzinger , M. Bregant , C. L. Britton , E. J. Brucken , H. Caines , A. J. Castro , S. Chattopadhyay , P. Christiansen , L. G. Clonts , T. M. Cormier , S. Das , S. Dash , A. Deisting , S. Dittrich , A. K. Dubey , R. Ehlers , M. Engel , F. Erhardt , N. B. Ezell , L. Fabbietti , U. Frankenfeld , J. J. Gaardhøje , C. Garabatos , P. Gasik , Á. Gera , P. Ghosh , S. K. Ghosh , P. Glässel , O. Grachov , A. Grein , T. Gunji , H. Hamagaki , G. Hamar , J. W. Harris , P. Hauer , J. Hehner , E. Hellbär , H. Helstrup , T. E. Hilden , B. Hohlweger , M. Ivanov , M. Jung , D. Just , E. Kangasaho , R. Keidel , B. Ketzer , S. A. Khan , S. Kirsch , T. Klemenz , S. Klewin , A. G. Knospe , M. Kowalski , L. Kumar , R. Lang , R. Langoy , L. Lautner , F. Liebske , J. Lien , C. Lippmann , H. M. Ljunggren , W. J. Llope , S. Mahmood , T. Mahmoud , R. Majka , P. Malzacher , A. Marín , C. Markert , S. Masciocchi , A. Mathis , A. Matyja , M. Meres , D. L. Mihaylov , D. Miskowiec , J. Mitra , T. Mittelstaedt , T. Morhardt , J. Mulligan , R. H. Munzer , K. Münning , M. G. Munhoz , S. Muhuri , H. Murakami , B. K. Nandi , H. Natal da Luz , C. Nattrass , T. K. Nayak , R. A. Negrao De Oliveira , M. Nicassio , B. S. Nielsen , L. Oláh , A. Oskarsson , J. Otwinowski , K. Oyama , G. Paić , R. N. Patra , V. Peskov , M. Pikna , L. Pinsky , M. Planinic , M. G. Poghosyan , N. Poljak , F. Pompei , S. K. Prasad , C. A. Pruneau , J. Putschke , S. Raha , J. Rak , J. Rasson , V. Ratza , K. F. Read , A. Rehman , R. Renfordt , T. Richert , K. Røed , D. Röhrich , T. Rudzki , R. Sahoo , S. Sahoo , P. K. Sahu , J. Saini , B. Schaefer , J. Schambach , S. Scheid , C. Schmidt , H. R. Schmidt , N. V Schmidt , H. Schulte , K. Schweda , I. Selyuzhenkov , N. Sharma , D. Silvermyr , R. N. Singaraju , B. Sitar , N. Smirnov , S. P. Sorensen , F. Sozzi , J. Stachel , E. Stenlund , P. Strmen , I. Szarka , G. Tambave , K. Terasaki , A. Timmins , K. Ullaland , A. Utrobicic , D. Varga , R. Varma , A. Velure , V. Vislavicius , S. Voloshin , B. Voss , D. Vranic , J. Wiechula , S. Winkler , J. Wikne , B. Windelband , C. Zhao

In the last few years our group have focused on developing various designs of spark-protected micropattern gaseous detectors featuring resistive electrodes instead of the traditional metallic ones: resistive microstrip counters, resistive…

Instrumentation and Detectors · Physics 2015-06-04 P. Fonte , E. Nappi , P. Martinengo , R. Oliveira , V. Peskov F. Pietropaolo , P. Picchi

Resistive Plate Counters (RPC) detectors at the Large Hadron Collider (LHC) experiments use gas recirculation systems to cope with large gas mixture volumes and costs. In this paper a long-term systematic study about gas purifiers, gas…

This work has been carried out to simulate a Resistive Plate Chamber and corroborate it with experimental measurements in order to develop a numerical tool for studying the performance of the device for any gas mixture. This will allow us…

Instrumentation and Detectors · Physics 2021-02-03 Jaydeep Datta , Sridhar Tripathy , Nayana Majumdar , Supratik Mukhopadhyay

Operation and performance of the Resistive Plate Chambers (RPCs) mostly depend on the quality and characteristics of the electrode materials. The India-based Neutrino Observatory collaboration has chosen glass RPCs as the active detector…

Instrumentation and Detectors · Physics 2016-08-03 K. Raveendrababu , P. K. Behera , B. Satyanarayana , Jafar Sadiq

In the DeeMe experiment, approximately $70\ \mathrm{GHz/mm^{2}}$ prompt-charged particles will hit the multi-wire proportional chambers (MWPCs) before signal electrons come. To avoid the space charge effect, we developed fast HV-switching…

Instrumentation and Detectors · Physics 2018-12-05 N. Teshima

In this paper we would like to present a few characteristics of the Resistive Plate Chambers (RPC) made of a particular grade of bakelite paper laminates (P-120, NEMA LI-1989 Grade XXX), produced and commercially available in India. This…

Instrumentation and Detectors · Physics 2010-11-02 S. Biswas , S. Bhattacharya , S. Bose , S. Chattopadhyay , S. Saha , Y. P. Viyogi

The muon identification system of the ALICE experiment at the CERN LHC is based on Resistive Plate Chamber (RPC) detectors. These RPCs are operated in the so-called maxi-avalanche mode with a gas mixture made of tetrafluoroethane…

Instrumentation and Detectors · Physics 2020-01-29 A. Bianchi , S. Delsanto , P. Dupieux , A. Ferretti , M. Gagliardi , B. Joly , S. P. Manen , M. Marchisone , L. Micheletti , A. Rosano , E. Vercellin

The applications of Resistive Plate Chambers (RPCs) have recently been extended by the development of counters with time resolution below 100 ps sigma for minimum ionising particles. Applications to HEP experiments have already taken place…

Instrumentation and Detectors · Physics 2009-11-07 A. Blanco , P. Fonte , L. Lopes , A. Mangiarotti , R. Ferreira-Marques , A. Policarpo
‹ Prev 1 4 5 6 7 8 10 Next ›