English
Related papers

Related papers: Gradiometry-free noise suppression in RF atomic ma…

200 papers

We show that it is possible to measure polarization with a polarimeter that gets rid of the seeing while still measuring at a frequency well below that of the seeing. We study a standard polarimeter made of two retarders and a beamsplitter.…

Instrumentation and Methods for Astrophysics · Physics 2016-04-20 A. Asensio Ramos

We study the effect of optical polarization squeezing on the performance of a sensitive, quantum-noise-limited optically pumped magnetometer. We use Bell-Bloom (BB) optical pumping to excite a $^{87}$Rb vapor containing $8.2 \cdot 10^{12}…

Quantum Physics · Physics 2021-11-05 C. Troullinou , R. Jiménez-Martínez , J. Kong , V. G. Lucivero , M. W. Mitchell

We propose a novel paradigm to vector magnetometry based on machine learning. Unlike conventional schemes where one measured signal explicitly connects to one parameter, here we encode the three-dimensional magnetic-field information in the…

Instrumentation and Detectors · Physics 2023-10-04 Xin Meng , Youwei Zhang , Xichang Zhang , Shenchao Jin , Tingran Wang , Liang Jiang , Liantuan Xiao , Suotang Jia , Yanhong Xiao

A recently introduced tuning-dressed scheme makes a Bell and Bloom magnetometer suited to detect weak variations of a radio-frequency (RF) magnetic field. We envisage the application of such innovative detection scheme as an alternative (or…

Instrumentation and Detectors · Physics 2021-11-03 Giuseppe Bevilacqua , Valerio Biancalana , Yordanka Dancheva , Alessandro Fregosi , Gaetano Napoli , Antonio Vigilante

In gate-defined quantum dot systems, the conductance change of electrostatically coupled sensor dots allows the observation of the quantum dots' charge and spin states. Therefore, the sensor dot must be optimally sensitive to changes in its…

Mesoscale and Nanoscale Physics · Physics 2025-08-12 Fabian Hader , Jan Vogelbruch , Simon Humpohl , Tobias Hangleiter , Chimezie Eguzo , Stefan Heinen , Stefanie Meyer , Stefan van Waasen

This work investigates the behavior of a spin-exchange relaxation-free (SERF) magnetometer integrated into the feedback branch of a closed-loop control circuit, designed to actively suppress noise from a current source. In this…

Atom interferometry has become one of the most powerful technologies for precision measurements. To develop simple, precise, and versatile atom interferometers for inertial sensing, we demonstrate an atom interferometer measuring…

Atomic Physics · Physics 2018-02-13 Xuejian Wu , Fei Zi , Jordan Dudley , Ryan J. Bilotta , Philip Canoza , Holger Müller

We demonstrate a proof-of-principle magnetometer that relies on the active oscillation of a cold atom Raman laser to continuously map a field-sensitive atomic phase onto the phase of the radiated light. We demonstrate wideband sensitivity…

Atomic Physics · Physics 2015-06-11 Joshua M. Weiner , Kevin C. Cox , Justin G. Bohnet , Zilong Chen , James K. Thompson

In a typical Rydberg mixer, modulated communication signals are detected using a radio frequency (RF) heterodyne technique. The mixer outputs an intermediate frequency (IF), which must be filtered and mixed down to baseband. In this work,…

Electromagnetic induction imaging with atomic magnetometers has disclosed unprecedented domains for imaging, from security screening to material characterization. However, applications to low-conductivity specimens -- most notably for…

Atomic Physics · Physics 2019-09-02 Luca Marmugi , Cameron Deans , Ferruccio Renzoni

The detection of environmental magnetic fields is well established by optically pumped atomic magnetometers. Another focus of magnetometry can be the research on magnetic or spin-active solid-state samples. Here we introduce a simple and…

Atomic Physics · Physics 2017-03-08 Daniel Arnold , Steven Siegel , Emily Grisanti , Jörg Wrachtrup , Ilja Gerhardt

Present protocols for obtaining the ultimate magnetic sensitivity of optically pumped magnetometers (OPMs) utilizing alkali-metal ensembles rely on uncorrelated atoms in stretched states. A new approach for calculating the spin projection…

Quantum Physics · Physics 2024-02-23 K. Mouloudakis , V. Koutrouli , I. K. Kominis , M. W. Mitchell , G. Vasilakis

We show that the use of Random Optical Grating using UV Exposure (ROGUE) can significantly reduce the noise floor of an optical frequency domain reflectometry (OFDR) measurement of Faraday rotation in the polarization. We compare it with…

A versatile magnetometer must deliver a readable response when exposed to target fields in a wide range of parameters. In this work, we experimentally demonstrate that the combination of $^{171}$Yb$^{+}$ atomic sensors with adequately…

Quantum Physics · Physics 2023-01-02 Yan Chen , Yue Ban , Ran He , Jin-Ming Cui , Yun-Feng Huang , Chuan-Feng Li , Guang-Can Guo , Jorge Casanova

This paper introduces a method for characterizing the current noise of commercial constant-current sources(CCSs) using a free-induction-decay(FID) type optically-pumped rubidium atomic magnetometer driven by a radio-frequency(RF) magnetic…

Atomic Physics · Physics 2023-09-07 Ni Zhao , Lulu Zhang , Yongbiao Yang , Jun He , Yanhua Wang , Tingyu Li , Junmin Wang

We describe our research programme on the use of atomic magnetometers to detect conductive objects via electromagnetic induction. The extreme sensitivity of atomic magnetometers at low frequencies, up to seven orders of magnitude higher…

Atomic Physics · Physics 2016-05-09 Sarah Hussain , Luca Marmugi , Cameron Deans , Ferruccio Renzoni

Atom interferometry offers new perspectives for geophysics and inertial sensing. We present the industrial prototype of a new type of quantum-based instrument: a compact, transportable, differential quantum gravimeter capable of measuring…

We evaluate the sensitivity of a dual cloud atom interferometer to the measurement of vertical gravity gradient. We study the influence of most relevant experimental parameters on noise and long-term drifts. Results are also applied to the…

Quantum Physics · Physics 2015-06-18 F. Sorrentino , Q. Bodart , L. Cacciapuoti , Y. -H. Lien , M. Prevedelli , G. Rosi , L. Salvi , G. M. Tino

Rydberg atom electric field sensors are tunable quantum sensors that can perform sensitive radio frequency (RF) measurements. Their qualities have piqued interest at longer wavelengths where their small size compares favorably to…

The spatial resolution of imaging magnetometers has benefited from scanning probe techniques. The requirement that the sample perturbs the scanning probe through a magnetic field external to its volume limits magnetometry to samples with…

Quantum Physics · Physics 2017-04-05 J. van Bree , M. E. Flatté