English
Related papers

Related papers: Radiation damage of SiPMs

200 papers

Silicon Photomultipliers (SiPMs) are single photon detectors that gained increasing interest in many applications as an alternative to photomultiplier tubes. In particular in the field of space experiments, where volume, weight and power…

Instrumentation and Detectors · Physics 2024-05-14 Stefano Merzi , Fabio Acerbi , C. Aicardi , D. Fiore , V. Goiffon , Alberto Gola , O. Marcelot , A. Materne , O. Saint-Pe

Silicon Photo-Multipliers (SiPM) are becoming the photo-detector of choice for increasingly more particle detection applications, from fundamental physics to medical and societal applications. One major consideration for their use at…

Instrumentation and Detectors · Physics 2018-12-26 M. Centis Vignali , E. Garutti , R. Klanner , D. Lomidze , J. Schwandt

Measured response functions and low photon yield spectra of silicon photomultipliers (SiPM) were compared to multi-photoelectron pulse-height distributions generated by a Monte Carlo model. Characteristic parameters for SiPM were derived.…

Nuclear Experiment · Physics 2008-11-26 S. Sanchez Majos , P. Achenbach , J. Pochodzalla

The effects of radiation damage in silicon photomultipliers (SiPMs) from gamma rays have been measured and compared with the damage produced by neutrons. Several types of MPPCs from Hamamatsu were exposed to gamma rays and neutrons at the…

Instrumentation and Detectors · Physics 2019-09-04 B. Biró , G. David , A. Fenyvesi , J. S. Haggerty , J. Kierstead , E. J. Mannel , T. Majoros , J. Molnar , F. Nagy , S. Stoll , B. Ujvari , C. L. Woody

Limited radiation hardness is the primary drawback to implementing Silicon Photomultipliers (SiPMs) in high-luminosity environments, such as the Compressed Baryonic Matter (CBM) experiment. Hadron irradiation generates defects in the…

Instrumentation and Detectors · Physics 2025-09-24 Jesús Peña-Rodríguez , Jörg Förtsch , Christian Pauly , Karl-Heinz Kampert

Silicon Photomultipliers (SiPMs) are quickly replacing traditional photomultiplier tubes (PMTs) as the readout of choice for gamma-ray scintillation detectors in space. While they offer substantial size, weight and power saving, they have…

Instrumentation and Detectors · Physics 2021-02-03 Lee J. Mitchell , Bernard Phlips , W. Neil Johnson , Mary Johnson-Rambert , Anika N. Kansky , Richard Woolf

Silicon photomultipliers (SiPMs) are highly-sensitive photodetectors emerging as the technology of choice for many applications, including large high-energy physics experiments where they often are exposed to high radiation fluences. In…

Instrumentation and Detectors · Physics 2022-08-17 A. R. Altamura , F. Acerbi , C. Nociforo , V. Regazzoni , A. Mazzi , A. Gola

The main effect of radiation damage in a Silicon-Photolumtiplier (SiPM) is a dramatic increase in the dark current. The power dissipated, if not properly cooled, heats the SiPM, whose performance parameters depend on temperature. Heating…

Instrumentation and Detectors · Physics 2022-07-20 E. Garutti , R. Klanner , E. Popova , S. Martens , J. Schwandt , C. Villalba

In this work we study the performance of silicon photomultiplier (SiPM) light sensors after exposure to the JULIC cyclotron proton beam, of energy $\sim$ 39 MeV, relative to their performance before exposure. The SiPM devices used in this…

Instrumentation and Detectors · Physics 2020-11-19 Tamer Tolba , Dieter Grzonka , Thomas Sefzick , James Ritman

This paper proposes an automatic procedure, based on ROOT data Analysis Framework, for the analysis of Silicon Photomultipliers (SiPM) characteristics. In particular, it can be used to analyze experimental waveforms, from oscilloscope,…

Instrumentation and Detectors · Physics 2019-07-10 Andrii Nagai , Nicoleta Dinu-Jaeger , Adam Para

Radiation damage to a Silicon Photomultiplier (SiPM), as it occurs during the lifetime of the planned CMS high-granularity calorimeter detector, increases the dark current and degrades the signal-to-noise separation for minimum-ionizing…

Instrumentation and Detectors · Physics 2026-05-29 Katjana Neumann , Massimiliano Antonello , Lukas Brinkmann , Erika Garutti , Jörn Schwandt

The characterisation of radiation-damaged SiPMs is a major challenge, when the average time between dark counts approaches, or even exceeds, the signal decay time. In this note a collection of formulae is presented, which have been…

Instrumentation and Detectors · Physics 2017-09-18 E. Garutti , R. Klanner , D. Lomidze , J. Schwandt , M. Zvolsky

Radiation damage of J-series silicon photomultipliers (SiPMs) has been studied in the context of using these photodetectors in future space-borne scintillation detectors. Several SiPM samples were exposed to 101.4 MeV protons, with 1 MeV…

We have investigated the effects of X-ray irradiation to doses of 0, 200 Gy, 20 kGy, 2 MGy, and 20 MGy on the Hamamatsu silicon-photomultiplier (SiPM) S10362-11-050C. The SiPMs were irradiated without applied bias voltage. From…

Instrumentation and Detectors · Physics 2014-06-12 Chen Xu , Robert Klanner , Erika Garutti , Wolf-Lukas Hellweg

Silicon photomultipliers present saturation effects as they have a limited number of pixels and work in Geiger mode. Their response to light pulses in the nonlinear region is very complex for two reasons: pixel recharging after an avalanche…

Instrumentation and Detectors · Physics 2018-12-26 Jaime Rosado

Number-resolving single photon detectors are essential for the implementation of numerous innovative quantum information schemes. While several number-discriminating techniques have been previously presented, the Silicon Photo-Multiplier…

Quantum Physics · Physics 2015-05-30 L. Dovrat , M. Bakstein , D. Istrati , H. S. Eisenberg

Silicon photomultipliers, thanks to their excellent performance, robustness and relatively simple use, are the photon-detectors of choice for many present and future applications. This paper gives an overview of methods to characterise…

Instrumentation and Detectors · Physics 2018-12-19 Robert Klanner

We report on the measurement of the radiation hardness of silicon photomultipliers (SiPMs) manufactured by Fondazione Bruno Kessler in Italy (1 mm$^2$ and 6.2 mm$^2$), Center of Perspective Technology and Apparatus in Russia (1 mm$^2$ and…

Instrumentation and Detectors · Physics 2009-01-09 P. Bohn , A. Clough , E. Hazen , A. Heering , J. Rohlf , J. Freeman , S. Los , E. Cascio , S. Kuleshov , Y. Musienko , C. Piemonte

Silicon PhotoMultipliers (SiPM) are an excellent choice for the scintillator light readout at hadron calorimeters due to their insensitivity to magnetic fields, low operating voltages, low cost, compactness and mechanical endurance. They…

Instrumentation and Detectors · Physics 2020-01-29 V. Mikhaylov , F. Guber , A. Ivashkin , A. Kugler , V. Kushpil , S. Morozov , O. Svoboda , P. Tlusty

In this paper the efficiency of direct charged particle detection with different Silicon PhotoMultiplier (SiPM) sensors has been measured to be close to 100%. Time resolution of about 20 ps has also been confirmed for sensors with an active…

‹ Prev 1 2 3 10 Next ›