English
Related papers

Related papers: The CMS RPC Detector Performance and Stability dur…

200 papers

The CMS experiment, located at the CERN Large Hadron Collider, has a redundant muon system composed by three different detector technologies: Cathode Strip Chambers (in the forward regions), Drift Tubes (in the central region) and Resistive…

The muon spectrometer of the CMS (Compact Muon Solenoid) experiment at the Large Hadron Collider (LHC) is equipped with a redundant system made of Resistive Plate Chambers and Drift Tube in barrel and RPC and Cathode Strip Chamber in endcap…

Instrumentation and Detectors · Physics 2015-06-22 G. Pugliese

The muon spectrometer of the CMS (Compact Muon Solenoid) experiment at the Large Hadron Collider (LHC) is equipped with a redundant system made of Resistive Plate Chambers (RPCs) and Drift Tube (DT) chambers in the barrel, RPC and Cathode…

Instrumentation and Detectors · Physics 2017-06-22 M. I. Pedraza-Morales , M. A. Shaha , M. Shopova

The Resistive Plate Chambers detector system at the CMS experiment at the LHC provides robustness and redundancy to the muon trigger. A total of 1056 double-gap chambers cover the pseudo-rapidity region < 1.6. The main detector parameters…

Instrumentation and Detectors · Physics 2016-05-31 Mehar Ali Shah

The muon system of the CMS experiment is expected to upgrade all of its subdetectors for the Phase-2 of the Large Hadron Collider (LHC) that will begin in 2029. The upgrade plans for drift tubes (DTs), cathode strip chambers (CSCs) and…

Instrumentation and Detectors · Physics 2023-12-19 Antonello Pellecchia

The performance of all subsystems of the CMS muon detector has been studied by using a sample of proton--proton collision data at sqrt(s) = 7 TeV collected at the LHC in 2010 that corresponds to an integrated luminosity of approximately 40…

Instrumentation and Detectors · Physics 2014-03-12 The CMS Collaboration

The contribution of Resistive Plate Chamber (RPC) to muon reconstruction in CMS has been studied on a sample of muons collected in proton-proton collisions at sqrt(s) = 7 TeV at the LHC in 2011. Muon reconstruction is performed using the…

Instrumentation and Detectors · Physics 2019-08-14 Min Suk Kim

The CMS muon system includes in both the barrel and endcap region Resistive Plate Chambers (RPC). They mainly serve as trigger detectors and also improve the reconstruction of muon parameters. Over the years, the instantaneous luminosity of…

During Phase-2 of the LHC, known as the High Luminosity LHC (HL-LHC), the accelerator will increase its instantaneous luminosity to 5 $\times$ 10$^{34}$ cm$^{-2}$ s$^{-1}$, delivering an integrated luminosity of 3000 fb$^{-1}$ over 10 years…

Instrumentation and Detectors · Physics 2020-07-24 Priyanka Kumari

The CMS experiment collected around 150 fb$^{-1}$ of proton-proton collision data at $\sqrt{s}$ = 13 TeV during the Run-2 data taking period of LHC. The CMS RPC system provided redundant information for robust muon triggering,…

Instrumentation and Detectors · Physics 2022-12-01 Kevin Mota Amarilo

The muon system of the CERN Compact Muon Solenoid (CMS) experiment includes more than a thousand Resistive Plate Chambers (RPC). They are gaseous detectors operated in the hostile environment of the CMS underground cavern on the Large…

Instrumentation and Detectors · Physics 2023-07-19 E. Shumka , A. Samalan , M. Tytgat , M. El Sawy , G. A. Alves , F. Marujo , E. A. Coelho , E. M. Da Costa , H. Nogima , A. Santoro , S. Fonseca De Souza , D. De Jesus Damiao , M. Thiel , K. Mota Amarilo , M. Barroso Ferreira Filho , A. Aleksandrov , R. Hadjiiska , P. Iaydjiev , M. Rodozov , M. Shopova , G. Soultanov , A. Dimitrov , L. Litov , B. Pavlov , P. Petkov , A. Petrov , S. J. Qian , H. Kou , Z. -A. Liu , J. Zhao , J. Song , Q. Hou , W. Diao , P. Cao , C. Avila , D. Barbosa , A. Cabrera , A. Florez , J. Fraga , J. Reyes , Y. Assran , M. A. Mahmoud , Y. Mohammed , I. Crotty , I. Laktineh , G. Grenier , M. Gouzevitch , L. Mirabito , K. Shchablo , I. Bagaturia , I. Lomidze , Z. Tsamalaidze , V. Amoozegar , B. Boghrati , M. Ebraimi , M. Mohammadi Najafabadi , E. Zareian , M. Abbrescia , G. Iaselli , G. Pugliese , F. Loddo , N. De Filippis , R. Aly , D. Ramos , W. Elmetenawee , S. Leszki , I. Margjeka , D. Paesani , L. Benussi , S. Bianco , D. Piccolo , S. Meola , S. Buontempo , F. Carnevali , L. Lista , P. Paolucci , F. Fienga , A. Braghieri , P. Salvini , P. Montagna , C. Riccardi , P. Vitulo , E. Asilar , J. Choi , T. J. Kim , S. Y. Choi , B. Hong , K. S. Lee , H. Y. Oh , J. Goh , I. Yu , C. Uribe Estrada , I. Pedraza , H. Castilla-Valdez , A. Sanchez-Hernandez , R. L. Fernandez , M. Ramirez-Garcia , E. Vazquez , M. A. Shah , N. Zaganidis , A. Radi , H. Hoorani , S. Muhammad , A. Ahmad , I. Asghar , W. A. Khan , J. Eysermans , F. Torres Da Silva De Araujo

The CMS muon detector system, muon reconstruction software, and high-level trigger underwent significant changes in 2013-2014 in preparation for running at higher LHC collision energy and instantaneous luminosity. The performance of the…

Instrumentation and Detectors · Physics 2018-06-21 CMS Collaboration

The CMS experiment recorded 177.75 /fb of proton-proton collision data during the RUN-1 and RUN-2 data taking period. Successful data taking at increasing instantaneous luminosities with the evolving detector configuration was a big…

Instrumentation and Detectors · Physics 2020-12-30 Mehar Ali Shah

The muon trigger system of the CMS experiment uses a combination of hardware and software to identify events containing a muon. During Run 2 (covering 2015-2018) the LHC achieved instantaneous luminosities as high as 2 $\times$…

High Energy Physics - Experiment · Physics 2021-07-06 CMS Collaboration

The Resistive Plate Chambers (RPCs) are employed in the CMS experiment at the LHC as dedicated trigger system both in the barrel and in the endcap. This note presents results of the RPC detector uniformity and stability during the 2011 data…

The Muon Upgrade Phase II of the Compact Muon Solenoid (CMS) aims to guarantee the optimal conditions of the present system and extend the $\eta$ coverage to ensure a reliable system for the High Luminosity Large Hadron Collider (HL-LHC)…

Instrumentation and Detectors · Physics 2020-06-17 M. I. Pedraza-Morales

The CMS muon system operates gas-based detectors. Upgrades of the detectors and trigger components are needed to cope with increasingly challenging conditions of the HL-LHC. New irradiation tests are performed to ensure that the muon…

Instrumentation and Detectors · Physics 2018-09-07 Jian Wang

The CMS muon system at the LHC is built of different detector technologies. The measurement of the background hit rates in the different muon detectors during the LHC Run-2 is of prime importance for an assessment of the longevity of the…

Instrumentation and Detectors · Physics 2020-04-22 Silvia Costantini

The trigger systems of the CERN LHC detectors play a crucial role in determining the physics capabilities of the experiments. A reduction of several orders of magnitude of the event rate is needed to reach values compatible with the…

Instrumentation and Detectors · Physics 2014-09-18 Juliette Alimena

The high pseudo-rapidity region of the CMS muon system is covered by Cathode Strip Chambers (CSC) only and lacks redundant coverage despite the fact that it is a challenging region for muons in terms of backgrounds and momentum resolution.…

‹ Prev 1 2 3 10 Next ›