English
Related papers

Related papers: ELT HARMONI: Image Slicer Preliminary Design

200 papers

SINFONI is an adaptive optics assisted near-infrared integral field spectrometer for the ESO VLT. The Adaptive Optics Module (built by the ESO Adaptive Optics Group) is a 60-elements curvature-sensor based system, designed for operations…

The scientific detector systems for the ESO ELT first-light instruments, HARMONI, MICADO, and METIS, together will require 27 science detectors: seventeen 2.5 $\mu$m cutoff H4RG-15 detectors, four 4K x 4K 231-84 CCDs, five 5.3 $\mu$m cutoff…

The Event Horizon Telescope (EHT) has produced images of the plasma flow around the supermassive black holes in Sgr A* and M87* with a resolution comparable to the projected size of their event horizons. Observations with the…

High Energy Astrophysical Phenomena · Physics 2023-03-15 Andrew Chael , Sara Issaoun , Dominic W. Pesce , Michael D. Johnson , Angelo Ricarte , Christian M. Fromm , Yosuke Mizuno

INTEGRAL is a hard X-ray/gamma-ray observatory for astrophysics (ESA) covering photon energies from 15 keV to 10 MeV. It was launched in 2002 and since then the BGO detectors of the Anti-Coincidence shield (ACS) of the SPI spectrometer have…

Solar and Stellar Astrophysics · Physics 2017-02-22 Rosa Rodríguez-Gasén , Jürgen Kiener , Vincent Tatischeff , Nicole Vilmer , Clarisse Hamadache , Karl-Ludwig Klein

Recent advances in optical metasurfaces enable control of the wavefront, polarization and dispersion of optical waves beyond the capabilities of conventional diffractive optics. An optical design space that is poised to highly benefit from…

We propose a new imaging technique for radio and optical/infrared interferometry. The proposed technique reconstructs the image from the visibility amplitude and closure phase, which are standard data products of short-millimeter very long…

Real-image super-resolution (Real-ISR) seeks to recover HR images from LR inputs with mixed, unknown degradations. While diffusion models surpass GANs in perceptual quality, they under-reconstruct high-frequency (HF) details due to a…

Computer Vision and Pattern Recognition · Computer Science 2026-04-14 Seungho Choi , Jeahun Sung , Jihyong Oh

HARMONI is a visible and near-infrared integral field spectrograph equipped with two complementary adaptive optics systems, fully integrated within the instrument. A Single Conjugate AO (SCAO) system offers high performance for a limited…

Maximizing the grating efficiency is a key goal for the first light instrument IRIS (Infrared Imaging Spectrograph) currently being designed to sample the diffraction limit of the TMT (Thirty Meter Telescope). Volume Phase Holographic (VPH)…

Instrumentation and Methods for Astrophysics · Physics 2015-06-22 Shaojie Chen , Elliot Meyer , Shelley A. Wright , Anna M. Moore , James E. Larkin , Jerome Maire , Etsuko Mieda , Luc Simard

We performed wave-optics-based numerical simulations at mid-infrared wavelengths to investigate how the presence or absence of entrance slits and optical aberrations affect the spectral resolving power $R$ of a compact,…

Instrumentation and Methods for Astrophysics · Physics 2022-07-04 Satoshi Itoh , Daisuke Ishihara , Takehiko Wada , Takao Nakagawa , Shinki Oyabu , Hidehiro Kaneda , Yasuhiro Hirahara , the SMI consortium

Aims: In this work, we discuss a way to combine High Dispersion Spectroscopy and High Contrast Imaging (HDS+HCI). For a planet located at a resolvable angular distance from its host star, the starlight can be reduced up to several orders of…

The BIFROST instrument will be the first VLTI instrument optimised for high spectral resolution up to R=25,000 and operate between 1.05 and 1.7 $\mu$m. A key component of the instrument will be the spectrograph, where we require a high…

Instrumentation and Methods for Astrophysics · Physics 2022-08-11 Sorabh Chhabra , Michele Frangiamore , Stefan Kraus , Andrea Bianco , Francisco Garzon , John Monnier , Daniel Mortimer

The spectral resolution of a dispersive spectrograph is dependent on the width of the entrance slit. This means that astronomical spectrographs trade-off throughput with spectral resolving power. Recently, optical guided-wave transitions…

We report on the design, development and commissioning of an Integral Field Unit (IFU) that has been built for the Echellette Spectrograph and Imager (ESI) at the W.M. Keck Observatory. This image slicer--based IFU, which was commissioned…

Astrophysics · Physics 2009-11-11 A. I. Sheinis

METIS is one of the three first-light instruments planned for the ELT, mainly dedicated to high contrast imaging in the mid-infrared. On the SPHERE high-contrast instrument currently installed at the VLT, we observe that one of the main…

The next generation of Extremely Large Telescopes (ELT), with diameters up to 39 meters, is planned to begin operation in the next decade and promises new challenges in the development of instruments since the instrument size increases in…

Instrumentation and Methods for Astrophysics · Physics 2017-11-03 N. Blind , E. Le Coarer , P. Kern , S. Gousset

We present a progress report on the design and construction of the Field-Imaging Far-Infrared Line Spectrometer (FIFI LS) for the SOFIA airborne observatory. The design of the instrument is driven by the goal of maximizing observing…

Astrophysics · Physics 2015-06-24 L. W. Looney , N. Geis , R. Genzel , W. K. Park , A. Poglitsch , W. Raab , D. Rosenthal , A. Urban , T. Henning

Holographic displays hold the promise of providing authentic depth cues, resulting in enhanced immersive visual experiences for near-eye applications. However, current holographic displays are hindered by speckle noise, which limits…

Graphics · Computer Science 2024-11-01 Florian Schiffers , Grace Kuo , Nathan Matsuda , Douglas Lanman , Oliver Cossairt

The latest generation of high-resolution spectrograph instruments on 10m-class telescopes continue to pursue challenging science cases. Consequently, ever more precise calibration methods are necessary to enable trail-blazing science…

Label-free nonlinear optical microscopy has become a powerful tool for biomedical research. However, the possible photodamage risk hinder further clinical applications. To reduce these adverse effects, we constructed a new platform of…

Optics · Physics 2022-10-26 Geng Wang , Stephen A. Boppart , Haohua Tu
‹ Prev 1 3 4 5 6 7 10 Next ›