Related papers: Exploring Fine Subpixel Spatial Resolution of Hybr…
Dynamic x-ray studies may reach temporal resolutions limited by only the x-ray pulse duration if the detector is fast enough to segregate synchrotron pulses. An analog integrating pixel array detector with in-pixel storage and temporal…
We present preliminary characterization of the Speedster-EXD, a new event driven hybrid CMOS detector (HCD) developed in collaboration with Penn State University and Teledyne Imaging Systems. HCDs have advantages over CCDs including lower…
The ATLAS collaboration will replace its tracking detector with new all silicon pixel and strip systems. This will allow to cope with the higher radiation and occupancy levels expected after the 5-fold increase in the luminosity of the LHC…
The Large Hadron Collider (LHC) at CERN will undergo an upgrade in order to increase its luminosity to $7.5 \times 10^{34}$ cm$^{-2}$s$^{-1}$. The increased luminosity during this High-Luminosity running phase (HL-LHC), starting around…
Pixel Detectors, as the current technology of choice for the innermost vertex detection, have reached a stage at which large detectors have been built for the LHC experiments and a new era of developments, both for hybrid and for monolithic…
At the High Luminosity Large Hadron Collider (HL-LHC), silicon pixel detectors will be exposed to radiation fluences about 5 to 10 times larger than those experienced by the current innermost pixel layers up to today. Signal loss will be…
The European X-ray Free Electron Laser (XFEL) will deliver 30,000 fully coherent, high brilliance X-ray pulses per second each with a duration below 100 fs. This will allow the recording of diffraction patterns of single complex molecules…
A dedicated in-vacuum X-ray detector based on the hybrid pixel PILATUS 1M detector has been installed at the four-crystal monochromator beamline of PTB at the electron storage ring BESSY II in Berlin. Due to its windowless operation, the…
We have developed an improved method of time-resolved x-ray reflectivity (XRR) using monochromatic synchrotron radiation. Our method utilizes a polycapillary x-ray optic to create a range of incident angles and an area detector to collect…
A graphene-optimized silicon carbide PIN detector was fabricated and its radiation tolerance under X-ray irradiation of 160 keV was evaluated. Its electrical properties, charge collection performance and time resolution of beta-particles…
For large scale applications, hybrid pixel detectors, in which sensor and read-out IC are separate entities, constitute the state of the art in pixel detector technology to date. They have been developed and start to be used as tracking…
X-ray detectors made of crystalline silicon have several advantages including low dark currents, fast charge collection and high energy resolution. For high-energy x-rays, however, silicon suffers from its low atomic number, which might…
The purpose of this project is to investigate the use of charge couple devices (CCDs) to detect electrons directly. This can be done in transmission electron microscopy (TEM) for electrons over 100 KeV, but for space plasma instruments,…
We describe a high resolution imaging detector based on a single 80 mm micro-channel-plate (MCP) and a phosphor screen mounted on a UHV flange of only 100 mm inner diameter. It relies on standard components and we describe its performance…
We report on preliminary design studies of a pixel detector for CMS at the Super-LHC. The goal of these studies was to investigate the possibility of designing an inner tracker pixel detector whose data could be used for selecting events at…
We are currently investigating the spatial resolution of highly pixelated Cadmium Zinc Telluride (CZT) detector for imaging applications. A 20 mm {\times} 20 mm {\times} 5 mm CZT substrate was fabricated with 600 {\mu}m pitch pixels (500…
In view of the high luminosity phase of the LHC (HL-LHC) to start operation around 2026, a major upgrade of the tracker system for the ATLAS experiment is in preparation. The expected neutron equivalent fluence of up to 2.4 * 1e16 1 MeV…
We report on the assessment of the imaging performance of CITIUS -- a high-speed X-ray detector developed for the large-scale synchrotron radiation facility SPring-8-II -- for heavy charged particles and neutrons. To characterize the…
The Compact Muon Solenoid (CMS) is one of two general-purpose detectors that reconstruct the products of high energy particle interactions at the Large Hadron Collider at CERN. The silicon pixel detector is the innermost component of the…
The discovery potential for charged Higgs bosons has been studied including background simulations for sqrts = 500 GeV and a luminosity of 10 fb-1 depending on the hadronic calorimeter resolution of a LC500 detector. The hadronic decay…