English
Related papers

Related papers: Spatially Resolved Dark Count Rate of SiPMs

200 papers

Radiation damage to a Silicon Photomultiplier (SiPM), as it occurs during the lifetime of the planned CMS high-granularity calorimeter detector, increases the dark current and degrades the signal-to-noise separation for minimum-ionizing…

Instrumentation and Detectors · Physics 2026-05-29 Katjana Neumann , Massimiliano Antonello , Lukas Brinkmann , Erika Garutti , Jörn Schwandt

Silicon photomultipliers (SiPMs) have a low radioactivity, compact geometry, low operation voltage, and reasonable photo-detection efficiency for vacuum ultraviolet light (VUV). Therefore it has the potential to replace photomultiplier…

Instrumentation and Detectors · Physics 2021-03-24 K. Ozaki , S. Kazama , M. Yamashita , Y. Itow , S. Moriyama

Dark count rate and correlated noise rate are among the main parameters that characterize silicon photomultipliers (SiPM). Typically, these parameters are evaluated by applying approximate formulas, or by fitting specific models, to the…

Instrumentation and Detectors · Physics 2017-11-01 Enrico Junior Schioppa

Silicon Photomultipliers (SiPMs) are state-of-the-art photon detectors used in particle physics, medical imaging, and beyond. They are sensitive to individual photons in the optical wavelength regime and achieve time resolutions of a few…

The application of silicon photomultiplier (SiPM) technology for weak-light detection at a single photon level has expanded thanks to its better photon detection efficiency in comparison to a conventional photomultiplier tube (PMT). SiPMs…

The barrel section of the novel MIP Timing Detector (MTD) will be constructed as part of the upgrade of the CMS experiment to provide a time resolution for single charged tracks in the range of $30-60$ ps using LYSO:Ce crystal arrays read…

We introduce a technique to mitigate the effects of low frequency noise on precision timing. The example of Dark Count Noise Rate (DCR) in Silicon Photomultipliers (SiPMs) is emphasized. This technique exploits the correlation between time…

Instrumentation and Detectors · Physics 2023-08-09 Sebastian N. White

Silicon Photo-Multipliers (SiPM) are becoming the photo-detector of choice for increasingly more particle detection applications, from fundamental physics to medical and societal applications. One major consideration for their use at…

Instrumentation and Detectors · Physics 2018-12-26 M. Centis Vignali , E. Garutti , R. Klanner , D. Lomidze , J. Schwandt

Conventional silicon photomultipliers (SiPMs) are well established as light detectors with single-photon-detection capability and used throughout high energy physics, medical, and commercial applications. The possibility to produce single…

Silicon Photo-Multipliers (SiPMs) are semiconductor-based photo-detectors with performances similar to the traditional Photo-Multiplier Tubes (PMTs). An increasing number of experiments dedicated to particle detection in colliders,…

Instrumentation and Detectors · Physics 2020-12-30 P. W. Cattaneo , A. Menegolli , M. C. Prata , G. L. Raselli , M. Rossella

In this work we will document the design and the performances of a SiPM-based photodetector with a surface area of 100 cm$^2$ conceived to operate as a replacement for PMTs. The signals from 94 SiPMs are summed up to produce an aggregated…

Muon scattering tomography is a non-destructive technique used to image different materials by utilizing natural cosmic ray muons. Typically it requires position-sensitive detectors with a sub-millimeter resolution to effectively…

Instrumentation and Detectors · Physics 2025-02-19 Binghao Sun , Huiling Li , Quanyin Li , Hui Liang , Cong Liu , Hongbo Wang , Zibing Wu , Suyu Xiao , Weiwei Xu

The analog hadron calorimeter for the International Linear Collider (ILC) of the CALICE collaboration utilized novel silicon detectors, the Sillicon Photomultipliers (SiPMs), for the detection of scintillation light coming from very small…

Instrumentation and Detectors · Physics 2012-11-28 Michal Tesař , Christian Jendrysik , Jelena Ninković , Frank Simon

This paper presents the results of the proton irradiation of silicon photomulipliers (SiPMs) by mono-energetic 170 MeV protons with fluence up to 4.6$\times$10$^{9}$ particles/cm$^2$. In our work, three types of silicon photodetectors from…

In this paper the efficiency of direct charged particle detection with different Silicon PhotoMultiplier (SiPM) sensors has been measured to be close to 100%. Time resolution of about 20 ps has also been confirmed for sensors with an active…

This publication focuses on the study of silicon photomultipliers (SiPMs) in view of a reconstruction of the incident photon flux in the regime of highly non-linear response. SiPMs are semiconductor based light detectors compiled of…

Instrumentation and Detectors · Physics 2020-10-29 T. Bretz , T. Hebbeker , J. Kemp

A novel concept to enhance the photo-detection efficiency (PDE) of silicon photomultipliers (SiPMs) has been applied and remarkable positive results can be reported. This concept uses arrays of microlenses to cover every second SiPM pixel…

Silicon PhotoMultipliers (SiPM) are an excellent choice for the scintillator light readout at hadron calorimeters due to their insensitivity to magnetic fields, low operating voltages, low cost, compactness and mechanical endurance. They…

Instrumentation and Detectors · Physics 2020-01-29 V. Mikhaylov , F. Guber , A. Ivashkin , A. Kugler , V. Kushpil , S. Morozov , O. Svoboda , P. Tlusty

Silicon Photomultipliers (SiPM) represent a promising alternative to classical photomultipliers, for instance, for the detection of photons in high energy physics and medical physics. In the present work, electrical characterizations of…

Instrumentation and Detectors · Physics 2017-08-23 M. J. Boschini , C. Consolandi , P. G. Fallica , M. Gervasi , D. Grandi , M. Mazzillo , S. Pensotti , P. G. Rancoita , D. Sanfilippo , M. Tacconi , G. Valvo

We demonstrate fast counting and multiphoton detection abilities of a Silicon Photo Multiplier (SiPM). In fast counting mode we are able to detect two consecutive photons separated by only 2.3 ns corresponding to 430 MHz. The counting…

Quantum Physics · Physics 2009-11-13 P. Eraerds , M. Legre , A. Rochas , H. Zbinden , N. Gisin
‹ Prev 1 2 3 10 Next ›