English
Related papers

Related papers: Development of gaseous particle detectors based on…

200 papers

We describe the most recent efforts made by various groups in implementing resistive electrodes in micropattern gaseous detectors with the aim to combine in the same design the best features of RPCs (for the example, their robustness and…

Instrumentation and Detectors · Physics 2015-05-18 P. Fonte , P. Martinengo , E. Nappi , R. Oliveira , V. Peskov , F. Pietropaolo , P. Picchi

Resistive Plate Chamber (RPC) is a gaseous detector, known for its good spatial resolution and excellent time resolution. Due to its fast response and excellent time resolution, it is used for both triggering and timing purpose. But the…

Instrumentation and Detectors · Physics 2022-10-26 Jaydeep Datta , Nayana Majumdar , Supratik Mukhopadhyay , Sandip Sarkar

We performed a new series of systematic studies of gain and rate characteristics of several micropattern gaseous detectors. Extending earlier studies, these measurements were done at various pressures, gas mixtures, at a wide range of…

Instrumentation and Detectors · Physics 2007-05-23 V. Peskov , P. Fonte , M. Danielsson , C. Iacobaeus , J. Ostling , M. Wallmark

To meet the need for a high counting rate and high time resolution in future high-energy physics experiments, a prototype of a gas photodetector with an RPC structure was developed. Garfield++ simulated the detector's performance, and the…

Instrumentation and Detectors · Physics 2024-07-30 Yiding Zhao , D. Hu , M. Shao , Y. Zhou , S. Lv , Xiangqi Tian , Anqi Wang , Xueshen Lin , Hao Pang , Y. Suna

Nowadays RPCs are in a booming phase: they are successfully used in many experiments, including LHC; there are ambitious plans to use them in several upgrade detectors and in some new experiments as well as in various applications. The aim…

Instrumentation and Detectors · Physics 2012-04-11 V. Peskov

Resistive Plate Chambers (RPCs) featuring 1 mm gas volumes combined with high-pressure phenolic laminate (HPL) electrodes provide excellent timing resolution down to a few hundred picoseconds, along with spatial resolution on the order of a…

The Multigap Resistive Plate Chambers (MRPCs) are gas ionization detectors with multiple gas sub-gaps made of resistive electrodes. The high voltage (HV) is applied on the outer surfaces of outermost resistive plates only, while the…

Instrumentation and Detectors · Physics 2016-12-16 Moon Moon Devi , Naba K. Mondal , B. Satyanarayana , R. R. Shinde

The Multi-gap Resistive Plate Chamber (MRPC) is an advanced form of Resistive Plate Chamber (RPC) detector where the gas gap is divided into sub-gaps. MRPCs are known for their good time resolution and detection efficiency for charged…

Instrumentation and Detectors · Physics 2018-08-15 Rajesh Ganai , Mitali Mondal , Shaifali Mehta , Zubayer Ahammed , Subhasis Chattopadhyay

The limitation of the detection rate of standard bakelite resistive plate chambers (RPC) used as muon detectors in the LHC experiments has prevented the use of such detectors in the high rate regions in both CMS and ATLAS detectors. One…

Instrumentation and Detectors · Physics 2015-06-12 Y. Haddad , G. Grenier , I. Laktineh , N. Lumb , S. Cauwenbergh

The Micro-Pattern Gaseous Detectors offer excellent spatial and temporal resolution in harsh radiation environments of high-luminosity colliders. In this work, an attempt has been made to establish an algorithm for estimating the time…

Instrumentation and Detectors · Physics 2016-05-11 Purba Bhattacharya , Nayana Majumdar , Supratik Mukhopadhyay , Sudeb Bhattacharya

Usage of electrodes made of glass with low bulk resistivity seems to be a promising way to adapt the Resistive Plate Chambers (RPC) to the high-rate environment of the upcoming CBM experiment. A pilot four-gap RPC sample with electrodes…

Resistive Plate Chambers (RPCs) exhibit a significant loss of efficiency for the detection of particles, when subjected to high particle fluxes. This rate limitation is related to the usually high resistivity of the resistive plates used in…

Instrumentation and Detectors · Physics 2015-09-08 M. Affatigato , U. Akgun , B. Bilki , F. Corriveau , B. Freund , N. Johnson , C. Neubueser , Y. Onel , J. Repond , L. Xia

A new type of resistive plate chamber with thin-film electrodes based on diamond-like carbon is under development for background identification in the MEG II experiment. Installed in a low-momentum and high-intensity muon beam, the detector…

Instrumentation and Detectors · Physics 2023-07-19 Kensuke Yamamoto , Sei Ban , Kei Ieki , Atsuhiko Ochi , Rina Onda , Wataru Ootani , Atsushi Oya , Masato Takahashi

Photosensitive gaseous detectors with a simple photoelectron multiplication mechanism of resistive plate chambers (RPCs) are expected to have both a large photocoverage and an excellent time resolution and to be low-cost. To demonstrate the…

Instrumentation and Detectors · Physics 2023-05-24 K. Matsuoka , R. Okubo , Y. Adachi

The intrinsic rate capability and the ageing properties of the Resistive Plate Chambers are closely related to the electrodes material and to the front-end electronics threshold. The development of a low noise pre-amplifier led us to…

A 100um thick silicon detector with 1mm2 pad readout optimized for sub-nanosecond time resolution has been developed and tested. Coupled to a purposely developed amplifier based on SiGe HBT technology, this detector was characterized at the…

Resistive gaseous detectors can be broadly defined as those operated in conditions where virtually no field lines exist that connect any two metallic electrodes sitting at different potential. This condition can be operationally recognized…

Instrumentation and Detectors · Physics 2015-06-05 Diego Gonzalez-Diaz , Archana Sharma

Single gap (gas gap 2 mm) bakelite Resistive Plate Chamber (RPC) modules of various sizes from 10 cm \times 10 cm to 1 m \times 1 m have been fabricated, characterized and optimized for efficiency and time resolution. Thin layers of…

Instrumentation and Detectors · Physics 2015-06-05 K. K. Meghna , A. Banerjee , S. Biswas , S. Bhattacharya , S. Bose , S. Chattopadhyay , G. Das , C. Marick , S. Saha , Y. P. Viyogi

For precise start time determination a Beam Fragmentation T$_0$ Counter (BFTC) is under development for the Time-of-Flight Wall of the Compressed Baryonic Matter Spectrometer (CBM) at the Facility for Antiproton and Ion Research (FAIR) at…

This paper presents the study on the characterization of glass electrodes, which are one of the main components of detectors like Resistive Plate Chambers (RPCs). The RPCs are being used in various ongoing High Energy Physics experiments,…

Instrumentation and Detectors · Physics 2022-03-01 R. Kanishka , V. Bhatnagar