Related papers: Testing the X-IFU calibration requirements: an exa…
The jet energy calibration and its uncertainties are derived from measurements of the calorimeter response to single particles in both data and Monte Carlo simulation using proton-proton collisions at $\sqrt{s} = 13$ TeV collected with the…
We report our most recent progress and demonstration of a frequency domain multiplexing (FDM) readout technology for transition-edge sensor (TES) arrays, both of which we have been developing, in the framework of the X-IFU instrument on…
We investigate whether collider experiments can reach the quantum limit of precision, defined by the quantum Fisher information (QFI), using only classical observables such as particle momenta. As a case study, we focus on the…
The Resolve soft X-ray spectrometer is the high spectral resolution microcalorimeter spectrometer for the XRISM mission. In the beam of Resolve there is a filter wheel containing \xray{} filters. In the beam also is an active calibration…
Uncalibrated instrument transformers (ITs) can degrade the performance of downstream applications that rely on the voltage and current measurements that ITs provide. It is also well-known that phasor measurement unit (PMU)-based system-wide…
A detailed spectroscopic study of the ISO-SWS data of the red giant Alpha Tau is presented, which enables not only the accurate determination of the stellar parameters of Alpha Tau, but also serves as a critical review of the ISO-SWS…
We have used the transition disk model to fit the simultaneous broad band ($2-500$ keV) spectrum of Cygnus X-1 from OSSE and Ginga observations. In this model, the spectrum is produced by saturated Comptonization within the inner region of…
To study and monitor the Sun and its atmosphere, various space missions have been launched in the past decades. With the rapid improvement in technology and different mission requirements, the data products are subject to constant change.…
The Spectrometer/Telescope for Imaging X-rays (STIX) is one of the 10 instruments on-board the scientific payload of ESA's Solar Orbiter mission. STIX provides hard X-ray imaging spectroscopy in the 4-150~keV energy range, observing hard…
We present the calibration of the Insight-Hard X-ray Modulation Telescope (Insight-HXMT) X-ray satellite, which can be used to perform timing and spectral studies of bright X-ray sources. Insight-HXMT carries three main payloads onboard:…
Correct radar data fusion depends on knowledge of the spatial transform between sensor pairs. Current methods for determining this transform operate by aligning identifiable features in different radar scans, or by relying on measurements…
The ATHENA X-ray Observatory is the second large-class mission in the ESA Cosmic Vision 2015-2025 science programme. One of the two on-board instruments is the X-IFU, an imaging spectrometer based on a large array of TES microcalorimeters.…
The European X-ray Free Electron Laser (XFEL) will deliver 27000 fully coherent, high brilliance X-ray pulses per second each with a duration below 100 fs. This will allow the recording of diffraction patterns of single molecules and the…
The Hubble diagram of type-Ia supernovae (SNe-Ia) provides cosmological constraints on the nature of dark energy with an accuracy limited by the flux calibration of currently available spectrophotometric standards. The StarDICE experiment…
The Imager on Board Integral Satellite (IBIS) is the imaging instrument of the INTEGRAL satellite, the hard-X/soft-gamma ray ESA mission to be launched in 2001. It provides diagnostic capabilities of fine imaging (12' FWHM), source…
Soft protons are a potential threat for X-ray missions using grazing incidence optics, as once focused onto the detectors they can contribute to increase the background and possibly induce radiation damage as well. The assessment of these…
We improve by a factor of 4-20 the energy accuracy of the strongest soft X-ray transitions of Fe XVII ions by resonantly exciting them in an electron beam ion trap with a monochromatic beam at the P04 beamline of the PETRA III synchrotron…
Transition edge sensor microcalorimeters can measure x-ray and gamma-ray energies with very high energy resolution and high photon-collection efficiency. For this technology to reach its full potential in future x-ray observatories, each…
The Cryogenic AntiCoincidence Detector (CryoAC) is a key element of the X-ray Integral Field Unit (X-IFU) on board the future ATHENA X-ray observatory. It is a TES-based detector designed to reduce the particle background of the instrument,…
Grazing-Incidence X-ray fluorescence (GIXRF) analysis, which is closely related to total-reflection XRF, is a very powerful technique for the in-depth analysis of many types of technologically relevant samples, e.g. nanoparticle…