English
Related papers

Related papers: Lifetime Study of COTS ADC for SBND LAr TPC Readou…

200 papers

The Short Baseline Near Detector (SBND) is one of three liquid argon (LAr) neutrino detectors sitting in the Booster Neutrino Beam (BNB) at Fermilab as part of the Short Baseline Neutrino (SBN) program. The detector is in a cryostat holding…

Instrumentation and Detectors · Physics 2019-10-16 Shanshan Gao

Wide attention has been focused on cryogenic CMOS (Cryo-CMOS) operation because of its wide application and the improvement of CMOS performance. However, hot carrier degradation (HCD) becomes worsening at cryogenic temperature, which…

Applied Physics · Physics 2021-10-22 Yuanke Zhang , Chao Luo , Tengteng Lu , Yujing Zhang , Jun Xu , Guoping Guo

Radiation-tolerant, high speed, high density and low power commercial off-the-shelf (COTS) analog-to-digital converters (ADCs) are planned to be used in the upgrade to the Liquid Argon (LAr) calorimeter front end (FE) trigger readout…

Instrumentation and Detectors · Physics 2014-03-07 Xueye Hu , Hucheng Chen , Kai Chen , Joseph Mead , Shubin Liu , Qi An

ColdADC is a custom ASIC digitizer implemented in 65 nm CMOS technology using specialized techniques for long-term reliability in cryogenic environments. ColdADC was developed for use in the DUNE Far Detector complex, which will consist of…

Instrumentation and Detectors · Physics 2025-10-09 Wenjie Wu , Benjamin Jargowsky , Yiwen Xiao , Alejandro Yankelevich , Jianming Bian , Cheng-Ju Lin , Tarun Prakash , David Christian

In this paper we present the cryogenic functionality of the components of data links for the Liquid Argon Time Projection Chamber (LArTPC), a potential far site detector technology of the Long-Baseline Neutrino Experiment (LBNE). We have…

Instrumentation and Detectors · Physics 2022-02-11 Tiankuan Liu , Datao Gong , Suen Hou , Chonghan Liu , Da-Shung Su , Ping-kun Teng , Annie C. Xiang , Jingbo Ye

Transition-edge sensor (TES) is a highly sensitive device that is capable of detecting extremely low levels of energy. It is characterised by low noise performance and high energy resolution. A mature method for reading out TES signal is…

Instrumentation and Detectors · Physics 2025-02-11 N. Li , X. Ren , H. Gao , Z. Zhang , Y. Zhang , C. Liu , H. Li , Z. Li

Charge Coupled Devices (CCDs) have been successfully used in several high energy physics experiments over the past two decades. Their high spatial resolution and thin sensitive layers make them an excellent tool for studying short-lived…

Instrumentation and Detectors · Physics 2008-11-26 Andre Sopczak

Cold electronics is a key technology in many areas of science and technology including space exploration programs and particle physics. A major experiment with a very large number of analog and digital electronics signal processing channels…

Instrumentation and Detectors · Physics 2019-11-26 N. Poonthottathil , F. Krennrich , J. Eisch , A. Weinstein , L. J Bond , D. Barnard , Z. Zhang , L Koester

We designed a versatile analog front-end chip, called LTARS, for TPC-applications, primarily targeted at dual-phase liquid Ar-TPCs for neutrino experiments and negative-ion $\mu$-TPCs for directional dark matter searches. Low-noise…

The readout electronics upgrade for the ATLAS Liquid Argon Calorimeters at the CERN Large Hadron Collider requires a radiation-hard ADC. The design of a radiation-hard dual-channel 12-bit 40 MS/s pipeline ADC for this use is presented. The…

Instrumentation and Detectors · Physics 2017-06-07 Jayanth Kuppambatti , Jaroslav Ban , Timothy Andeen , Rex Brown , Ryne Carbone , Peter Kinget , Gustaaf Brooilmans , William Sippach

The low-noise operation of readout electronics in a liquid argon time projection chamber (LArTPC) is critical to properly extract the distribution of ionization charge deposited on the wire planes of the TPC, especially for the induction…

Instrumentation and Detectors · Physics 2023-02-17 MicroBooNE collaboration , R. Acciarri , C. Adams , R. An , J. Anthony , J. Asaadi , M. Auger , L. Bagby , S. Balasubramanian , B. Baller , C. Barnes , G. Barr , M. Bass , F. Bay , M. Bishai , A. Blake , T. Bolton , B. Bullard , L. Camilleri , D. Caratelli , B. Carls , R. Castillo Fernandez , F. Cavanna , H. Chen , E. Church , D. Cianci , E. Cohen , G. H. Collin , J. M. Conrad , M. Convery , J. I. Crespo-Anadon , G. De Geronimo , M. Del Tutto , D. Devitt , S. Dytman , B. Eberly , A. Ereditato , L. Escudero Sanchez , J. Esquivel , A. A. Fadeeva , B. T. Fleming , W. Foreman , A. P. Furmanski , D. Garcia-Gamez , G. T. Garvey , V. Genty , D. Goeldi , S. Gollapinni , N. Graf , E. Gramellini , H. Greenlee , R. Grosso , R. Guenette , A. Hackenburg , P. Hamilton , O. Hen , V Hewes , C. Hill , J. Ho , G. Horton-Smith , A. Hourlier , E. -C. Huang , C. James , J. Jan de Vries , C. -M. Jen , L. Jiang , R. A. Johnson , J. Joshi , H. Jostlein , D. Kaleko , G. Karagiorgi , W. Ketchum , B. Kirby , M. Kirby , T. Kobilarcik , I. Kreslo , A. Laube , S. Li , Y. Li , A. Lister , B. R. Littlejohn , S. Lockwitz , D. Lorca , W. C. Louis , M. Luethi , B. Lundberg , X. Luo , A. Marchionni , C. Mariani , J. Marshall , D. A. Martinez Caicedo , V. Meddage , T. Miceli , G. B. Mills , J. Moon , M. Mooney , C. D. Moore , J. Mousseau , R. Murrells , D. Naples , P. Nienaber , J. Nowak , O. Palamara , V. Paolone , V. Papavassiliou , S. F. Pate , Z. Pavlovic , E. Piasetzky , D. Porzio , G. Pulliam , X. Qian , J. L. Raaf , V. Radeka , A. Rafique , S. Rescia , L. Rochester , C. Rudolf von Rohr , B. Russell , D. W. Schmitz , A. Schukraft , W. Seligman , M. H. Shaevitz , J. Sinclair , A. Smith , E. L. Snider , M. Soderberg , S. Soldner-Rembold , S. R. Soleti , P. Spentzouris , J. Spitz , J. St. John , T. Strauss , A. M. Szelc , N. Tagg , K. Terao , M. Thomson , C. Thorn , M. Toups , Y. -T. Tsai , S. Tufanli , T. Usher , W. Van De Pontseele , R. G. Van de Water , B. Viren , M. Weber , D. A. Wickremasinghe , S. Wolbers , T. Wongjirad , K. Woodruff , T. Yang , L. Yates , B. Yu , G. P. Zeller , J. Zennamo , C. Zhang

Thick, fully depleted p-channel charge-coupled devices (CCDs) have been developed at the Lawrence Berkeley National Laboratory (LBNL). These CCDs have several advantages over conventional thin, n-channel CCDs, including enhanced quantum…

The \emph{MIDNA} application specific integrated circuit (ASIC) is a skipper-CCD readout chip fabricated in a 65 nm LP-CMOS process that is capable of working at cryogenic temperatures. The chip integrates four front-end channels that…

The design of a radiation-hard dual channel 12-bit 40 MS/s pipeline ADC with extended dynamic range is presented, for use in the readout electronics upgrade for the ATLAS Liquid Argon Calorimeters at the CERN Large Hadron Collider. The…

Instrumentation and Detectors · Physics 2015-06-16 Jayanth Kuppambatti , Jaroslav Ban , Timothy Andeen , Peter Kinget , Gustaaf Brooijmans

The MIDNA application specific integrated circuits (ASICs) are a series of skipper-CCD readout chips fabricated in a 65 nm low-power CMOS process that implement a correlated double sampling signal processing chain based on dual-slope…

The Short Baseline Near Detector (SBND) is a 112 ton active mass liquid argon time projection chamber (LArTPC) that will begin operations in the Booster Neutrino Beamline at Fermilab in 2020. Its main physics goals include high-statistics…

Instrumentation and Detectors · Physics 2019-10-21 Georgia Karagiorgi

Results from commissioning and first year of operations of the cryogenic system of the Short-Baseline Neutrino Detector (SBND) and its membrane cryostat installed at the Fermi National Accelerator Laboratory are described. The SBND detector…

An estimated 26 million people in low- and middle-income countries are at risk of lead exposure and there is no safe threshold for lead ingestion. Radio assay methods are not easily accessible in regions at risk, therefore a low cost and…

Instrumentation and Detectors · Physics 2020-01-08 Alexander Deisting

The ProtoDUNE-SP detector is a large-scale prototype of the Single-Phase (SP) Liquid Argon Time Projection Chamber (LArTPC) design proposed for the Deep Underground Neutrino Experiment (DUNE). 15,360 LArTPC wires are instrumented with low…

‹ Prev 1 2 3 10 Next ›