English
Related papers

Related papers: Prototype of Front-end Electronics for PandaX-4ton…

200 papers

We report on the assessment of the imaging performance of CITIUS -- a high-speed X-ray detector developed for the large-scale synchrotron radiation facility SPring-8-II -- for heavy charged particles and neutrons. To characterize the…

Instrumentation and Detectors · Physics 2026-05-25 Yoshio Kamiya , Haruki Nishino , Takaki Hatsui

For a future 5G Ethernet-based fronthaul architecture, 100G trunk lines of a transmission distance up to 10 km standard single mode fiber (SSMF) in combination with cheap grey optics to daisy chain cell site network interfaces are a…

The ATLAS experiment will undergo around the year 2025 a replacement of the tracker system in view of the high luminosity phase of the LHC (HL-LHC) with a new 5-layer pixel system. Thin planar pixel sensors are promising candidates to…

Instrumentation and Detectors · Physics 2017-02-01 Anna Macchiolo , Julien Beyer , Alessandro La Rosa , Richard Nisius , Natascha Savic

The signal digitization for CROSS, a bolometric experiment for the search of neutrinoless double beta decay at LSC - Canfranc Underground Laboratory, will be based on a custom solution comprised of an analog-to-digital board interfaced to…

Instrumentation and Detectors · Physics 2019-11-05 P. Carniti , C. Gotti , G. Pessina

We point out that the LDMX (Light Dark Matter eXperiment) detector design, conceived to search for sub-GeV dark matter, will also have very advantageous characteristics to pursue electron-nucleus scattering measurements of direct relevance…

High Energy Physics - Phenomenology · Physics 2020-04-07 Artur M. Ankowski , Alexander Friedland , Shirley Weishi Li , Omar Moreno , Philip Schuster , Natalia Toro , Nhan Tran

The multi-staged XENON program at INFN Laboratori Nazionali del Gran Sasso aims to detect dark matter with two-phase liquid xenon time projection chambers of increasing size and sensitivity. The XENONnT experiment is the latest detector in…

Instrumentation and Detectors · Physics 2025-08-14 XENON Collaboration , E. Aprile , J. Aalbers , K. Abe , S. Ahmed Maouloud , L. Althueser , B. Andrieu , E. Angelino , J. R. Angevaare , V. C. Antochi , D. Antón Martin , F. Arneodo , M. Balata , L. Baudis , A. L. Baxter , M. Bazyk , L. Bellagamba , R. Biondi , A. Bismark , E. J. Brookes , A. Brown , S. Bruenner , G. Bruno , R. Budnik , T. K. Bui , C. Cai , J. M. R. Cardoso , F. Cassese , A. Chiarini , D. Cichon , A. P. Cimental Chavez , A. P. Colijn , J. Conrad , R. Corrieri , J. J. Cuenca-García , J. P. Cussonneau , O. Dadoun , V. D'Andrea , M. P. Decowski , B. De Fazio , P. Di Gangi , S. Diglio , J. M. Disdier , D. Douillet , K. Eitel , A. Elykov , S. Farrell , A. D. Ferella , C. Ferrari , H. Fischer , M. Flierman , S. Form , D. Front , W. Fulgione , C. Fuselli , P. Gaemers , R. Gaior , A. Gallo Rosso , M. Galloway , F. Gao , R. Gardner , N. Garroum , R. Glade-Beucke , L. Grandi , J. Grigat , H. Guan , M. Guerzoni , M. Guida , R. Hammann , A. Higuera , C. Hils , L. Hoetzsch , N. F. Hood , J. Howlett , C. Huhmann , M. Iacovacci , G. Iaquaniello , L. Iven , Y. Itow , J. Jakob , F. Joerg , A. Joy , M. Kara , P. Kavrigin , S. Kazama , M. Kobayashi , G. Koltman , A. Kopec , F. Kuger , H. Landsman , R. F. Lang , L. Levinson , I. Li , S. Li , S. Liang , S. Lindemann , M. Lindner , K. Liu , J. Loizeau , F. Lombardi , J. Long , J. A. M. Lopes , Y. Ma , C. Macolino , J. Mahlstedt , A. Mancuso , L. Manenti , F. Marignetti , T. Marrodán Undagoitia , P. Martella , K. Martens , J. Masbou , D. Masson , E. Masson , S. Mastroianni , E. Mele , M. Messina , R. Michinelli , K. Miuchi , A. Molinario , S. Moriyama , K. Morå , Y. Mosbacher , M. Murra , J. Müller , K. Ni , S. Nisi , U. Oberlack , D. Orlandi , R. Othegraven , B. Paetsch , J. Palacio , S. Parlati , P. Paschos , Q. Pellegrini , R. Peres , C. Peters , J. Pienaar , M. Pierre , G. Plante , T. R. Pollmann , J. Qi , J. Qin , D. Ramírez García , M. Rynge , J. Shi , R. Singh , L. Sanchez , J. M. F. dos Santos , I. Sarnoff , G. Sartorelli , J. Schreiner , D. Schulte , P. Schulte , H. Schulze Eißing , M. Schumann , L. Scotto Lavina , M. Selvi , F. Semeria , P. Shagin , S. Shi , E. Shockley , M. Silva , H. Simgen , J. Stephen , M. Stern , B. K. Stillwell , A. Takeda , P. -L. Tan , D. Tatananni , A. Terliuk , D. Thers , F. Toschi , G. Trinchero , C. Tunnell , F. Tönnies , K. Valerius , G. Volta , C. Weinheimer , M. Weiss , D. Wenz , J. Westermann , C. Wittweg , T. Wolf , V. H. S. Wu , Y. Xing , D. Xu , Z. Xu , M. Yamashita , L. Yang , J. Ye , L. Yuan , G. Zavattini , M. Zhong , T. Zhu

The $\mu$eV axion is a well-motivated extension to the standard model. The Axion Dark Matter eXperiment (ADMX) collaboration seeks to discover this particle by looking for the resonant conversion of dark-matter axions to microwave photons…

We report the observation of the hyperfine spectrum of the weak P(63)4-4 line of the B-X electronic transition of molecular iodine 127I2 near 652.4 nm, using frequency-modulated saturated absorption spectroscopy. Through the precise…

We present the ARAGORN front-end, a cost-optimized, high-density Time-to-Digital Converter platform. Four Xilinx Artix-7 FPGAs implement 384 channels with an average time resolution of 165 ps on a single module. A fifth FPGA acts as data…

Instrumentation and Detectors · Physics 2017-03-08 Maximilian Büchele , Horst Fischer , Florian Herrmann , Carl Schaffer

The ProtoDUNE-SP detector is a large-scale prototype of the Single-Phase (SP) Liquid Argon Time Projection Chamber (LArTPC) design proposed for the Deep Underground Neutrino Experiment (DUNE). 15,360 LArTPC wires are instrumented with low…

The XENON1T experiment searches for dark matter particles through their scattering off xenon atoms in a 2 tonne liquid xenon target. The detector is a dual-phase time projection chamber, which measures simultaneously the scintillation and…

Instrumentation and Detectors · Physics 2019-07-03 E. Aprile , J. Aalbers , F. Agostini , M. Alfonsi , L. Althueser , F. D. Amaro , V. C. Antochi , F. Arneodo , L. Baudis , B. Bauermeister , M. L. Benabderrahmane , T. Berger , P. A. Breur , A. Brown , E. Brown , S. Bruenner , G. Bruno , R. Budnik , C. Capelli , J. M. R. Cardoso , D. Cichon , D. Coderre , A. P. Colijn , J. Conrad , J. P. Cussonneau , M. P. Decowski , P. de Perio , P. Di Gangi , A. Di Giovanni , S. Diglio , A. Elykov , G. Eurin , J. Fei , A. D. Ferella , A. Fieguth , W. Fulgione , A. Gallo Rosso , M. Galloway , F. Gao , M. Garbini , L. Grandi , Z. Greene , C. Hasterok , E. Hogenbirk , J. Howlett , M. Iacovacci , R. Itay , F. Joerg , S. Kazama , A. Kish , G. Koltman , A. Kopec , H. Landsman , R. F. Lang , L. Levinson , Q. Lin , S. Lindemann , M. Lindner , F. Lombardi , J. A. M. Lopes , E. López Fune , C. Macolino , J. Mahlstedt , A. Manfredini , F. Marignetti , T. Marrodán Undagoitia , J. Masbou , D. Masson , S. Mastroianni , M. Messina , K. Micheneau , K. Miller , A. Molinario , K. Morå , Y. Mosbacher , M. Murra , J. Naganoma , K. Ni , U. Oberlack , K. Odgers , B. Pelssers , F. Piastra , J. Pienaar , V. Pizzella , G. Plante , R. Podviianiuk , H. Qiu , D. Ramírez García , S. Reichard , B. Riedel , A. Rizzo , A. Rocchetti , N. Rupp , J. M. F. dos Santos , G. Sartorelli , N. Šarčević , M. Scheibelhut , S. Schindler , J. Schreiner , D. Schulte , M. Schumann , L. Scotto Lavina , M. Selvi , P. Shagin , E. Shockley , M. Silva , H. Simgen , C. Therreau , D. Thers , F. Toschi , G. Trinchero , C. Tunnell , N. Upole , M. Vargas , O. Wack , H. Wang , Z. Wang , Y. Wei , C. Weinheimer , D. Wenz , C. Wittweg , J. Wulf , J. Ye , Y. Zhang , T. Zhu , J. P. Zopounidis

The technical design of the PANDA experiment at the future FAIR facility next to GSI is progressing. At the proposed anti-proton storage ring the spectroscopy of double Lambda hypernuclei is one of the four main topics which will be…

Instrumentation and Detectors · Physics 2011-06-22 P. Achenbach , J. Pochodzalla , A. Sanchez Lorente , S. Sánchez Majos

This paper presents performance measurements of a new readout electronics system based on silicon photomultipliers for the PHENIX electromagnetic calorimeter. Installation of the lead-scintillator Shashlik style calorimeter into the…

We provide a comprehensive comparison of linear amplifiers and microwave photon-counters in axion dark matter experiments. The study is done assuming a range of realistic operating conditions and detector parameters, over the frequency…

The imaging performance of a high-resolution preclinical microPET system employing liquid xenon as the gamma ray detection medium was simulated. The arrangement comprises a ring of detectors consisting of trapezoidal LXe time projection…

Medical Physics · Physics 2012-03-23 A. Miceli , J. Glister , A. Andreyev , D. Bryman , L. Kurchaninov , P. Lu , A. Muennich , F. Retiere , V. Sossi

We report the long term performance of the photosensors, 143 one-inch R8520-406 and 37 three-inch R11410-MOD photomultipliers from Hamamatsu, in the first phase of the PandaX dual-phase xenon dark matter experiment. This is the first time…

The Data Acquisition System of the LZ experiment, the 10-tonne dark matter detector to be installed at the Sanford Underground Research Facility (SURF), will collect signals from 788 photomultiplier tubes (PMTs). Because the signals from…

Instrumentation and Detectors · Physics 2015-11-30 Eryk Druszkiewicz

Discrete multi-tone transmission (DMT) is a promising candidate for future 400G data center interconnects. Eight channels, each carrying 56 Gb/s of data can be combined in a 50-GHz channel grid to form a 400 Gb/s superchannel. For a fully…

Signal Processing · Electrical Eng. & Systems 2020-09-23 Annika Dochhan , Helmut Griesser , Nicklas Eiselt , Michael Eiselt , Jörg-Peter Elbers

Integration is currently the only feasible route towards scalable photonic quantum processing devices that are sufficiently complex to be genuinely useful in computing, metrology, and simulation. Embedded on-chip detection will be critical…