Related papers: Characterization of TOF-PET Detectors Based on Mon…

200 papers

Current clinical PET systems utilize detectors where the scintillator typically contains single elements of 3 - 6 mm width and about 20 mm height. While providing good TOF performance, this design limits the spatial resolution and causes…

Instrumentation and Detectors · Physics 2022-11-17 Florian Mueller , Stephan Naunheim , Yannick Kuhl , David Schug , Torsten Solf , Volkmar Schulz

Measurement of the Time-of-Flight (TOF) of the 511 keV gammas brings an important reduction of statistical noise in the PET image, with higher precision time measurements producing clearer images. Scintillating crystals are used to convert…

Instrumentation and Detectors · Physics 2019-12-03 K. Doroud , Z. Liu , M. C. S. Williams

Time-of-flight measurement is an important advancement in PET scanners to improve image reconstruction with a lower delivered radiation dose. This article describes the monolithic ASIC for the TT-PET project, a novel idea for a…

Coincidence time resolution (CTR) in time-of-flight positron emission tomography (TOF-PET) has significantly improved with advancements in scintillators, photodetectors, and readout electronics. Achieving a CTR of 100 ps remains challenging…

Instrumentation and Detectors · Physics 2024-12-25 Yuya Onishi , Ryosuke Ota

Accurate Time-of-Flight (TOF) measurement with sub-100 picosecond resolution is a critical requirement for particle identification in future high-energy physics experiments, such as the Belle II $K_{L}$ and Muon (KLM) detector upgrade.…

Instrumentation and Detectors · Physics 2026-05-14 Ziyi Yang , Xiyang Wang , Shiming Zou , Ting Wang , Kairui Huang , Wanyi Zhuang , Yicheng Pu , Xiaolong Wang

In this paper we prove that the choice of a suitable treatment of the scintillator surfaces, along with suitable photodetectors electronics and specific algorithms for raw data analysis, allow to achieve an optimal tradeoff between energy,…

Medical Physics · Physics 2012-03-02 Luigi Cosentino , Paolo Finocchiaro , Alfio Pappalardo , Franco Garibaldi

This work presents the 8-channel FastIC+, a low-power consumption and highly configurable multi-channel front-end ASIC with internal digitization, for the readout of photo-sensors with picosecond time resolution and intrinsic gain. This…

Recent tests of a single module of the Jagiellonian Positron Emission Tomography system (J-PET) consisting of 30 cm long plastic scintillator strips have proven its applicability for the detection of annihilation quanta (0.511 MeV) with a…

The TT-PET collaboration is developing a small animal TOF-PET scanner based on monolithic silicon pixel sensors in SiGe BiCMOS technology. The demonstrator chip, a small-scale version of the final detector ASIC, consists of a 3 x 10 pixel…

Timing-pick up detectors with excellent timing resolutions are essential in many modern nuclear physics experiments. Aiming to develop a Time-Of-Flight system with precision down to about 10 ps, we have made a systematic study of the timing…

Instrumentation and Detectors · Physics 2016-04-19 J. W. Zhao , B. H. Sun , I. Tanihata , S. Terashima , L. H. Zhu , A. Enomoto , D. Nagae , T. Nishimura , S. Omika , A. Ozawa , Y. Takeuchi , T. Yamaguchi

This paper describes the characterization of crystal matrices and silicon photomultiplier arrays for a novel Positron Emission Tomography (PET) detector, namely the external plate of the EndoTOFPET-US system. The EndoTOFPET-US collaboration…

Aiming to measure the difference in arrival times of two coincident gamma-photons with an accuracy in the order of 200 ps, time-of-flight positron emission tomography systems commonly employ silicon photomultipliers (SiPMs) and…

Medical Physics · Physics 2021-02-11 Vanessa Nadig , David Schug , Bjoern Weissler , Volkmar Schulz

Fast timing detectors are an essential element in the experimental setup for time-of-flight (ToF) mass measurements of unstable nuclei. We have upgraded the scintillator detectors used in experiments at the National Superconducting…

Semi monolithic detector designs with a series of stacked thin monolithic scintillator plates and side readout are an attractive approach for potentially achieving very high performance in a positron emission tomography (PET) scanner. In…

Instrumentation and Detectors · Physics 2025-02-12 Shiv K. Subedi , Simon R. Cherry , Yi Qiang , Peng Peng

We are exploring a scintillator-based detector with potential of high sensitivity, DOI capability and timing resolution in a single-side readout configuration. Our concept combines: 1) A design with 2+ crystal arrays stacked with relative…

Instrumentation and Detectors · Physics 2021-04-08 L. Bläckberg , S. Sajedi , G. El Fakhri , H. Sabet

Time-Of-Flight (TOF) is a noble technique that is used in Positron Emission Tomography (PET) imaging worldwide. The scintillator based imaging system that is being used around the world for TOF-PET is very expensive. Multi-gap Resistive…

Instrumentation and Detectors · Physics 2018-07-02 Rajesh Ganai , Shaifali Mehta , Mehulkumar Shiroya , Mitali Mondal , Zubayer Ahammed , Subhasis Chattopadhyay

Positron emission tomography (PET) is the most sensitive biomedical imaging modality for non-invasively detecting and visualizing positron-emitting radiopharmaceuticals within a subject. In PET, measuring the time-of-flight (TOF)…

Instrumentation and Detectors · Physics 2024-10-17 Minseok Yi , Daehee Lee , Alberto Gola , Stefano Merzi , Michele Penna , Jae Sung Lee , Simon R. Cherry , Sun Il Kwon

The aim of this work is to develop high precision Time-of-Flight (TOF) devices based on high refractive index solid Cherenkov radiators read out by silicon photomultipliers (SiPMs). Cherenkov light is prompt and therefore ideal for reaching…

The potential of photon detectors to achieve precise timing information is of increasing importance in many domains, PET and CT scanners in medical imaging and particle physics detectors, amongst others. The goal to increase by an order of…

Instrumentation and Detectors · Physics 2021-01-11 S. Enoch , A. Gola , P. Lecoq , A. Rivetti

Modeling the timing performance of light-based radiation detectors accurately is essential for optimizing time-of-flight positron emission tomography (TOF-PET). We present an analytic framework that combines existing models to predict the…

Instrumentation and Detectors · Physics 2025-10-08 Nicolaus Kratochwil , Emilie Roncali , Gerard Arino-Estrada