Related papers: FPGA code for the data acquisition and real-time p…
To achieve the aim of the ITER Radial Neutron Camera Diagnostic, the data acquisition prototype must be compliant with a sustained 2 MHz peak event for each channel with 128 samples of 16 bits per event. The data is acquired and processed…
The neutron detection system for characterization of emissivity in ITER Tokamak during DD and DT experiments poses serious challenges to the performance of the diagnostic control and data acquisition system (CDAcq). The ongoing design of…
For space-based astronomical observations, it is important to have a mechanism to capture the digital output from the standard detector for further on-board analysis and storage. We have developed a generic (application- wise)…
Scientific experiments rely on some type of measurements that provides the required data to extract aimed information or conclusions. Data production and analysis are therefore essential components at the heart of any scientific…
In this paper, a real-time 105-channel data acquisition platform based on FPGA for imaging will be implemented for mm-wave imaging systems. PC platform is also realized for imaging results monitoring purpose. Mm-wave imaging expands our…
Accurate and low-latency qubit state measurement is critical for trapped-ion quantum computing. While deep neural networks (DNNs) have been integrated to enhance detection fidelity, their latency performance on specific hardware platforms…
Inspired by Wilkinson ADC method, we implement a fast linear discharge method based on FPGA to digitize nuclear pulse signal. In this scheme, we use a constant current source to discharge the charge on capacitor which is integrated by the…
A noise-tolerant data communications fabric has been developed to meet the real-time data acquisition and control requirements of fast feedback loops, machine protection systems, pulse-to-pulse sequencing, and machine-experiment…
MCP-based detectors are widely used in the ultraviolet (UV) region due to their low noise levels, high sensitivity and good spatial and temporal resolution. We have developed a compact near-UV (NUV) detector for high-altitude balloon and…
LiDAR sensors have been widely used in many autonomous vehicle modalities, such as perception, mapping, and localization. This paper presents an FPGA-based deep learning platform for real-time point cloud processing targeted on autonomous…
Liquid argon time projection chambers (LArTPCs) have been proposed as neutrino detectors that combine both large sizes to maximize the number of neutrino interactions and detailed recording of the interaction. The readout of thousands of…
This paper presents a comprehensive review of recent advances in deploying convolutional neural networks (CNNs) for object detection, classification, and tracking on Field Programmable Gate Arrays (FPGAs). With the increasing demand for…
Two generations of a novel detector for high-resolution transmission imaging and spectrometry of fast-neutrons are presented. These devices are based on a hydrogenous fiber scintillator screen and single- or multiple-gated intensified…
Power-spectrum analysis is an important tool providing critical information about a signal. The range of applications includes communication-systems to DNA-sequencing. If there is interference present on a transmitted signal, it could be…
The analog signals generated in the read-out electronics of radiation detectors are shaped prior to the digitization in order to improve the signal to noise ratio (SNR). The real amplitude of the analog signal is then obtained using digital…
The ITER Vertical Neutron Camera (VNC) is a multichannel collimator system designed to measure the neutron emissivity profile and spectra. The energy spectrum measurements of neutrons made by the VNC will contribute to the reconstruction of…
Time-tagging units and coincidence detectors are used in many scientific research fields. The required timing resolution and number of input channels are varying, but some emerging experiments in the field of quantum optics require up to 32…
A calibration procedure is proposed for the ITER Radial Neutron Camera. No in-vessel calibration using external neutron sources is required: instead, it is proposed to rely on embedded sources, reference ITER pulses and cross-calibration…
It is very important to measure the plasma performances of fusion reactors such as fuel ion density, plasma temperature, fusion power, fast neutron energy, and neutron flux. Various diagnostic systems are needed to measure fast neutron…
Plenoptic cameras are receiving increasing attention in scientific and commercial applications because they capture the entire structure of light in a scene, enabling optical transforms (such as focusing) to be applied computationally after…