Related papers: A plastic scintillator array for reactor based ant…
We report the measurement of the non-reactor environmental backgrounds and the detector response with the Indian Scintillator Matrix for Reactor Anti-Neutrinos (ISMRAN), which is $\sim$1 ton detector setup by volume, consisting of…
We present a detailed study on detector response to different radioactive sources and the measurements of non-reactor environmental backgrounds with the Indian Scintillator Matrix for Reactor Anti-Neutrinos (ISMRAN) detector setup…
The Indian Scintillator Matrix for Reactor Anti-Neutrino detection - ISMRAN experiment aims to detect electron anti-neutrinos ($\bar\nu_e$) emitted from a reactor via inverse beta decay reaction (IBD). The setup, consisting of 1 ton…
We report measurement of reactor based electron anti-neutrinos from a prototype array of plastic scintillator bars ( mini-ISMRAN ) located inside Dhruva research reactor hall, BARC. The detector setup took data for 128 days for reactor on…
We report the measurements of the fast neutron energy response in Indian Scintillator Matrix for Reactor Anti-Neutrinos (ISMRAN) detector consisting of an array of 9$\times$10 Plastic Scintillator Bars (PSBs) at BARC, Mumbai. ISMRAN is an…
The Indian Scintillator Matrix for Reactor Anti-Neutrinos (ISMRAN) is an above-ground, very short baseline reactor anti-neutrino (${\overline{\ensuremath{\nu}}}_{e}$) experiment, located inside the Dhruva research reactor facility, Mumbai,…
The reactor antineutrinos are used for the precise measurement of oscillation parameters in the 3-neutrino model, and also used to investigate active-sterile neutrino mixing sensitivity in the 3$+$1 neutrino framework. In the present work,…
The cosmic rays data collected using a large area plastic scintillator array ISMRAN (Indian Scintillator Matrix for Reactor AntiNeutrino) are presented. The data collected serve as a useful benchmark of cosmogenic background in a…
Conceiving the possibility of using plastic scintillator bars as robust detectors for antineutrino detection for the remote reactor monitoring and nuclear safeguard application we study expected basic performance by Monte Carlo simulation.…
This study presents a new concept of segmented antineutrino detector based on hexagonal plastic scintillator bars for detecting antineutrinos from a nuclear reactor core. The choice of hexagonal scintillator bars is original and provides…
An aboveground 60-kg reactor-antineutrino detector prototype, comprised of a 2-dimensional array of 36 $^{6}$Li-doped pulse shape sensitive plastic scintillator bars, is described. Each bar is 50~cm long with a square cross section of…
We report results of fast neutron response in plastic scintillator (PS) bars from deuterium-deuterium (D-D) and deuterium-tritium (D-T) reactions using Purnima Neutron Generator Facility, BARC, Mumbai. These measurements are useful in…
In this work, we present an analysis of the sensitivity to the active-sterile neutrino mixing with the Indian Scintillator Matrix for Reactor Anti-Neutrino (ISMRAN) experimental set-up at very short baseline. In this article, we have…
We developed a segmented reactor-antineutrino detector made of plastic scintillators for application as a tool in nuclear safeguards inspection and performed mostly unmanned field operations at a commercial power plant reactor. At a…
We propose a new type segmented antineutrino detector made of plastic scintillators for the nuclear safeguard application. A small prototype was built and tested to measure background events. A satisfactory unmanned field operation of the…
Accelerator-driven system (ADS) facilities world-wide opens new opportunities for nuclear physics investigations, so that a high flux of neutrons through spallation reactions can be produced at these facilities. It is known that the…
In this study, simulation-based design and optimization studies of a gadolinium loaded segmented plastic scintillator detector are presented for monitoring applications of nuclear reactors in Turkey using antineutrinos. For the first time…
The next generation of very-short-baseline reactor experiments will require compact detectors operating at surface level and close to a nuclear reactor. This paper presents a new detector concept based on a composite solid scintillator…
A large area plastic scintillator detector array(~ 1 m x1m) has been set up for fast neutron spectroscopy at the BARC-TIFR Pelletron laboratory, Mumbai. The energy, time and position response has been measured for electrons using…
Technology developed for the T2K electromagnetic calorimeter has been adapted to make a small footprint, reliable, segmented detector to characterise anti-neutrinos emitted by nuclear reactors. The device has been developed and demonstrated…