English
Related papers

Related papers: The GMT detector alignment in the STAR experiment

200 papers

The Dark Matter Time Projection Chamber (DMTPC) is a direction-sensitive detector designed to measure the direction of recoiling $^{19}$F and $^{12}$C nuclei in low-pressure CF$_4$ gas using optical and charge readout systems. In this…

Instrumentation and Methods for Astrophysics · Physics 2017-06-21 Cosmin Deaconu , Michael Leyton , Ross Corliss , Gabriela Druitt , Richard Eggleston , Natalia Guerrero , Shawn Henderson , Jeremy Lopez , Jocelyn Monroe , Peter Fisher

We have studied the accuracy and reliability of the exposure time calculator (ETC) of the Wide Field Planetary Camera 2 (WFPC2) on board the Hubble Space Telescope (HST) with the objective of determining how well it represents actual…

Astrophysics · Physics 2009-11-07 G. Li Causi , G. De Marchi , F. Paresce

A pointing accuracy better than 1"(3sigma) star tracker plays a significant role for the advanced scientific missions. This thesis makes a series of studies on the typical error sources associated with the positioning and calibration…

Instrumentation and Methods for Astrophysics · Physics 2020-10-29 Jun Zhang

The ALICE experiment at the Large Hadron Collider (LHC) proposes major detector upgrades to fully exploit the increase of the luminosity of the LHC in RUN~3 and to extend the physics reach for rare probes at low transverse momentum. The…

Instrumentation and Detectors · Physics 2019-08-13 Taku Gunji

The present $\mathrm{R}\&\mathrm{D}$ activities for the International Large Detector Time Projection Chamber (ILD-TPC) concern the adoption of the micro pattern devices for the gaseous amplification stage. Seven Micromegas modules which are…

The analog front-end electronics based on the constant fraction discrimination method is designed and optimized for the Multigap Resistive Plate Chamber (MRPC) timing measurements. The total time resolution of 40 ps has been obtained for 10…

Instrumentation and Detectors · Physics 2025-05-29 L. L. Kurchaninov , E. A. Ladygin , V. P. Ladygin , A. A. Semak

Spatial resolution of less than 200 um is challenging for thermal neutron detection. A novel readout scheme based on the time-projection-chamber (TPC) concept is used in a gaseous electron multiplier (GEM) detector. Thermal neutrons are…

Instrumentation and Detectors · Physics 2016-06-22 Bernhard Flierl , Otmar Biebel , Ralf Hertenberger , Karl Zeitelhack

We present results of our study devoted to the development of a time correction algorithm needed to precisely synchronize a free-running Rubidium atomic clock with the Coordinated Universal Time (UTC). This R&D is performed in view of the…

A high momentum resolution is required for the precision measurement of Higgs boson at the International Linear Collider (ILC) using the recoil mass technique. The International Large Detector (ILD) is designed to meet this requirement by…

Instrumentation and Detectors · Physics 2020-02-28 Yumi Aoki

Using a portable star tracking system, we are able to obtain the geographical position of the observer, longitude, latitude and North direction. In this work, a new optimization method has been applied to improve accuracy in calculation of…

Instrumentation and Methods for Astrophysics · Physics 2018-08-02 Meysam Izadmehr , Mehdi Khakian Ghom

The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of…

Instrumentation and Detectors · Physics 2012-08-27 CMS Collaboration

The site selection group for the future Cherenkov Telescope Array (CTA) has deployed sensitive light sensors at 9 candidate sites, 5 of them in the Southern and 4 in the Northern hemisphere. The sensors are equipped with a PIN diode and a…

Instrumentation and Methods for Astrophysics · Physics 2019-08-14 Markus Gaug

Multi-gap Resistive Plate Chambers (MRPCs) with multi-strip readout are considered to be the optimal detector candidate for the Time-of-Flight (ToF) wall in the Compressed Baryonic Matter (CBM) experiment. In the R&D phase MRPCs with…

Instrumentation and Detectors · Physics 2016-11-23 I. Deppner , N. Herrmann , J. Frühauf , M. Kiš , P. Lyu , P. -A. Loizeau , L. Shi , C. Simon , Y. Wang , B. Xie

A cylindrical GEM detector is under development, to serve as an upgraded inner tracker at the BESIII spectrometer. It will consist of three layers of cylindrically-shaped triple GEMs surrounding the interaction point. The experiment is…

Time of flight of a minimum ionizing particle along a fixed base has been measured with a 100 ps accuracy by means of a Dielectric Resistive Plate Chamber (DRPC) with 4 x 0.3 mm gas gaps. DRPC timing characteristics have been studied with…

Instrumentation and Detectors · Physics 2007-05-23 A. Akindinov , V. Golovin , A. Martemiyanov , V. Petrov , V. Plotnikov , A. Smirnitsky , K. Voloshin

Background: The established GADGET detection system, designed for measuring weak, low-energy $\beta$-delayed proton decays, features a gaseous Proton Detector with MICROMEGAS readout for calorimetric particle detection, surrounded by a…

MPGD are the new frontier in gas trackers. Among this kind of devices, theGEM chambers are widely used. The experimental signals acquired with the detector mustobviously be reconstructed and analysed. In this contribution, a new offline…

Resistive Plate Chambers (RPCs) featuring 1 mm gas volumes combined with high-pressure phenolic laminate (HPL) electrodes provide excellent timing resolution down to a few hundred picoseconds, along with spatial resolution on the order of a…

A high-precision charge measurement can be achieved by the area integration of a digitized quasi-Gaussian signal after the signal passes through the shaper and analog-to-digital converter (ADC). The charge measurement contains an error due…

Instrumentation and Detectors · Physics 2019-09-26 Jiajin Zhang , Lei Zhao , Ruoshi Dong , Peipei Deng , Cong Ma , Jiaming Lu , Shubin Liu , Qi An