The Transition-Edge Sensor (TES) is an extremely sensitive device which is used to measure the energy of individual X-ray photons. For astronomical spectrometry applications, SRON develops a Frequency Domain Multiplexing (FDM) read-out…

Transition-edge sensors (TES) are photon-number resolving calorimetric spectrometers with near unit efficiency. Their recovery time, which is on the order of microseconds, limits the number resolving ability and timing accuracy in high…

Instrumentation and Detectors · Physics 2018-12-21 Jianwei Lee , Lijiong Shen , Alessandro Cerè , Thomas Gerrits , Adriana E. Lita , Sae Woo Nam , Christian Kurtsiefer

We have fabricated multilayer readout wiring Transition Edge Sensors (TES), which enable us to realize both large effective area and high-energy resolution for future X-ray astrophysical missions, such as DIOS. By sandwiching a SiO2…

Instrumentation and Detectors · Physics 2014-02-04 Shin'ya Yamada , Y. Ezoe , Y. Ishisaki , T. Ohashi , N. Iijima , K. Mitsuda , K. Nagayoshi , H. Akamatsu , T. Morooka , K. Tanaka

Transition Edge Sensors (TESs) are amongst the most sensitive cryogenic detectors and can be easily optimized for the detection of massive particles or photons ranging from X-rays all the way down to millimetre radiation. Furthermore, TESs…

Instrumentation and Detectors · Physics 2024-11-05 Mario De Lucia , Paolo Dal Bo , Eugenia Di Giorgi , Tommaso Lari , Claudio Puglia , Federico Paolucci

We demonstrate very high resolution photon spectroscopy with a microwave-multiplexed two-pixel transition-edge sensor (TES) array. We measured a $^{153}$Gd photon source and achieved an energy resolution of 63 eV full-width-at-half-maximum…

Superconducting transition-edge sensor (TES) detectors have been the standard in Cosmic Microwave Background experiments for almost two decades and are now being adapted for use in nuclear physics, such as neutrinoless double beta decay…

Transition Edge Sensors (TESs) are the selected technology for future spaceborne X-ray observatories, such as Athena, Lynx, and HUBS. These missions demand thousands of pixels to be operated simultaneously with high energy-resolving power.…

Microwave frequency domain multiplexing is a suitable technique to read out a large number of detector channels using only a few connecting lines. In the HOLMES experiment this is based on inductively coupled rf-SQUIDs (Superconducting…

Instrumentation and Detectors · Physics 2018-02-28 P. Carniti , L. Cassina , M. Faverzani , E. Ferri , A. Giachero , C. Gotti , M. Maino , A. Nucciotti , G. Pessina , A. Puiu

At Argonne National Laboratory, we are developing hard X-ray (2 to 20 keV) Transition Edge Sensor (TES) arrays for beamline science. The significantly improved energy resolution provided by superconducting detectors compared to…

Instrumentation and Detectors · Physics 2021-06-02 T. Guruswamy , L. Gades , A. Miceli , U. Patel , O. Quaranta

Multiplexers based on the modulation of superconducting quantum interference devices are now regularly used in multi-kilopixel arrays of superconducting detectors for astrophysics, cosmology, and materials analysis. Over the next decade,…

Instrumentation and Methods for Astrophysics · Physics 2012-05-02 K. D. Irwin , H. M. Cho , W. B. Doriese , J. W. Fowler , G. C. Hilton , M. D. Niemack , C. D. Reintsema , D. R. Schmidt , J. N. Ullom , L. R. Vale

We present the design, fabrication, and characterization of an aluminum-based six-channel microwave SQUID multiplexer ($\mu$MUX) prototype for transition-edge sensor (TES) readout in the RICOCHET experiment. The device consists of aluminum…

Instrumentation and Detectors · Physics 2026-05-26 James Amidei , Antoine Armatol , Corinne Augier , Louis Bailly-Salins , Guillaume Baulieu , Laurent Bergé , Julien Billard , Juliette Blé , Gaby Brenot , Guillaume Bres , Jean-Louis Bret , Alexandre Broniatowski , Martino Calvo , Antonella Cavanna , Antoine Cazes , Emanuela Celi , David Chaize , Mohammed Chala , Maurice Chapellier , Luke Chaplinsky , Ran Chen , Ion Cojocari , Jules Colas , Laurent Couraud , Elspeth Cudmore , Maryvonne De Jesus , Pierre de Marcillac , Nicole Dombrowski , Louis Dumoulin , Alan Durnez , Romain Faure , Sylvain Ferriol , Enectali Figueroa-Feliciano , Joseph A. Formaggio , Stephane Fuard , Jules Gascon , Cloé Girard-Carillo , Andrea Giuliani , Corinne Goy , Cyrille Guerin , Leïla Haegel , Patrick M. Harrington , Scott A. Hertel , Cyrus F. Hirjibehedin , Christophe Hoarau , Ziqing Hong , Daemon Howard , Jean-Christophe Ianigro , Yong Jin , Alexandre Juillard , Dimitar Karaivanov , Temirlan Khussainov , Andrew Kubik , Jacob Lamblin , Tatiana Le Bellec , Laetitia Leroy , Mingyu Li , Alexey Lubashevskiy , Stefanos Marnieros , Romain Martin , Nicolas Martini , Julien Minet , Alessandro Monfardini , Franck Mounier , Bethany M. Niedzielski , Valentina Novati , Wiliam D. Oliver , Emiliano Olivieri , H. Douglas Pinckney , Denys V. Poda , Dmitrii Ponomarev , Jean-Sébastien Real , Faith C. Reyes , Alejandro Rodriguez , Sergey Rozov , Irina Rozova , Brianna Ryan , Deeksha Sabhari , Silvia Scorza , Kyle Serniak , Renaud Serra , Yegor Shevchik , Torsten Soldner , Hannah Stickler , Caitlyn Stone-Whitehead , Christian Ulysse , Wouter Van De Pontseele , Sergey Vasilyev , Paul Vittaz , Steven Weber , Evan Wolfe , Wayne Woods , Evgeny Yakushev , Jiatong Yang , Daniya Zinatulina

The next-generation of cryogenic neutrinoless double-beta decay experiments require increasingly fast readout in order to improve background discrimination. These experiments, operated as cryogenic calorimeters at $\sim$10 mK, are usually…

The state-of-the-art technology of X-ray microcalorimeters based on superconducting transition edge sensors (TESs), for applications in astrophysics and particle physics, is reviewed. We will show the advance in understanding the detector…

Instrumentation and Methods for Astrophysics · Physics 2022-10-14 Luciano Gottardi , Kenichiro Nagayoshi

The next generation of ultra-low-noise cryogenic detectors for space science applications require continued exploration of materials characteristics at low temperatures. The low noise and good energy sensitivity of current Transition Edge…

Mesoscale and Nanoscale Physics · Physics 2011-02-01 D. J. Goldie , D. M. Glowacka , K. Rostem† , S. Withington

Transition-edge sensor (TES) is a highly sensitive device that is capable of detecting extremely low levels of energy. It is characterised by low noise performance and high energy resolution. A mature method for reading out TES signal is…

Instrumentation and Detectors · Physics 2025-02-11 N. Li , X. Ren , H. Gao , Z. Zhang , Y. Zhang , C. Liu , H. Li , Z. Li

At SRON we have been developing X-ray TES micro-calorimeters as backup technology for the X-ray Integral Field Unit (X-IFU) of the Athena mission, demonstrating excellent resolving powers both under DC and AC bias. We also developed a…

Instrumentation and Methods for Astrophysics · Physics 2025-06-04 D. Vaccaro , H. Akamatsu , L. Gottardi , M. de Wit , M. P. Bruijn , J. van der Kuur , K. Nagayoshi , E. Taralli , K. Ravensberg , J. R. Gao , J. W. A. den Herder

The scalability of most transition-edge sensor arrays is limited by the multiplexing technology which combines their signals over a reduced number of wires and amplifiers. In this Letter, we present and demonstrate a multiplexer design…

Transition-edge sensors (TESs) are sensitive devices for detecting photons from millimeter radiation to gamma rays. Their photon counting efficiency and collecting area benefit from large-array multiplexing scheme, and therefore the…

Instrumentation and Methods for Astrophysics · Physics 2024-04-03 N. Li , G. Liao , D. Yan , Y. Xu , Y. Zhang , Z. Liu , S. Yuan , Y. Zhang , H. Gao , Y. Li , Y. Gu , C. Liu , H. Li , Z. Li , X. Ren

We present X-ray absorption spectroscopy and resonant inelastic X-ray scattering (RIXS) measurements on the iron L-edge of 0.5 mM aqueous ferricyanide. These measurements demonstrate the ability of high-throughput transition-edge-sensor…

We are developing code-division multiplexing (CDM) systems for transition-edge sensor arrays with the goal of reaching multiplexing factors in the hundreds. We report on x-ray measurements made with a four-channel prototype CDM system that…

Instrumentation and Detectors · Physics 2012-05-04 J. W. Fowler , W. B. Doriese , G. C. Hilton , K. D. Irwin , D. R. Schmidt , G. M. Stiehl , D. S. Swetz , J. N. Ullom , L. R. Vale.