English
Related papers

Related papers: PMU Placement Optimization for Smart Grid Obvervab…

200 papers

With the proposition to install a large number of phasor measurement units (PMUs) in the future power grid, it is essential to provide robust communications infrastructure for phasor data across the network. We make progress in this…

Information Theory · Computer Science 2015-01-05 K. G. Nagananda , Shalinee Kishore , Rick S. Blum

Phasor measurement units (PMUs) have the advantage of providing direct measurements of power states. However, as the number of PMUs in a power system is limited, the traditional supervisory control and data acquisition (SCADA) system cannot…

Systems and Control · Computer Science 2016-07-12 Jian Du , Shaodan Ma , Yik-Chung Wu , H. Vincent Poor

Phasor measurement units (PMUs) enable better system monitoring and security enhancement in smart grids. In order to enhance power system resilience against outages and blackouts caused by extreme weather events or man-made attacks, it…

Systems and Control · Electrical Eng. & Systems 2020-10-16 Hamed Haggi , Wei Sun , Junjian Qi

The small amount of measurements in distribution grids makes their monitoring more difficult. Topological observability may not be possible, and thus, pseudo-measurements are needed to perform state estimation, which is required to control…

Systems and Control · Computer Science 2019-07-24 Miguel Picallo , Adolfo Anta , Bart De Schutter

The problem of effective use of Phasor Measurement Units (PMUs) to enhance power systems awareness and security is a topic of key interest. The central question to solve is how to use this new measurements to reconstruct the state of the…

Systems and Control · Electrical Eng. & Systems 2020-04-16 Alexey Bobtsov , Romeo Ortega , Nikolay Nikolaev , Johannes Schiffer , M. Nicolai L. Lorenz-Meyer

Time-synchronization attacks on phasor measurement units (PMU) pose a real threat to smart grids; it was shown that they are feasible in practice and that they can have a non-negligible negative impact on the state estimation, without…

Systems and Control · Electrical Eng. & Systems 2020-09-16 Marguerite Delcourt , Jean-Yves Le Boudec

Phasor measurement units (PMUs) provide a high-resolution view of the power system at the locations where they are placed. As such, it is desirable to place them in bulk in low voltage distribution circuits. However, the power consumption…

Phasor Measurement Units (PMUs) are being used extensively for electrical grid monitoring and control. However, their cost prohibits further adoption on the distribution grid and easy access for educational purposes. This paper proposes…

Systems and Control · Electrical Eng. & Systems 2023-05-30 Mislav Bui , Marko Jurčević

Power domination is a graph-theoretic model for the observance of a power grid using phasor measurement units (PMUs). There are many costs associated with the installation of a PMU, but also costs associated with not observing the entire…

Combinatorics · Mathematics 2026-02-19 Beth Bjorkman , Sean English , Johnathan Koch

We consider a power transmission system monitored with Phasor Measurement Units (PMUs) placed at significant, but not all, nodes of the system. Assuming that a sufficient number of distinct single-line faults, specifically pre-fault state…

Machine Learning · Statistics 2021-04-08 Andrei Afonin , Michael Chertkov

Installation of phasor measurement units (PMUs) in a number of substations in the power grid can help assess a set of its values and parameters, in particular those related to the dynamics when disturbances occur in the system. Inertia…

Systems and Control · Electrical Eng. & Systems 2021-04-19 Mohammadali Hayerikhiyavi , Aleksandar Dimitrovski

Due to limited metering infrastructure, distribution grids are currently challenged by observability issues. On the other hand, smart meter data, including local voltage magnitudes and power injections, are communicated to the utility…

Optimization and Control · Mathematics 2016-12-21 Siddharth Bhela , Vassilis Kekatos , Sriharsha Veeramachaneni

As the phasor measurement unit (PMU) placement problem involves a cost-benefit trade-off, more PMUs get placed on the higher voltage buses. However, this causes many of the lower voltage levels of the bulk power system to not be observed by…

Signal Processing · Electrical Eng. & Systems 2024-03-22 Antos Cheeramban Varghese , Hritik Shah , Behrouz Azimian , Anamitra Pal , Evangelos Farantatos

The optimal PMU locations to collect voltage phase angle measurements for detecting line outages in wide-area transmission networks are investigated. The problem is established as one of maximizing the minimum distance among the voltage…

Optimization and Control · Mathematics 2012-07-30 Yue Zhao , Andrea Goldsmith , H. Vincent Poor

Fast and accurate knowledge of power flows and power injections is needed for a variety of applications in the electric grid. Phasor measurement units (PMUs) can be used to directly compute them at high speeds; however, a large number of…

Systems and Control · Electrical Eng. & Systems 2026-02-11 Satyaprajna Sahoo , Anwarul Islam Sifat , Anamitra Pal

This paper presents an innovative approach to micro-phasor measurement unit (micro-PMU) placement in unbalanced distribution networks. The methodology accounts for the presence of single-and-two-phase laterals and acknowledges the fact that…

Systems and Control · Electrical Eng. & Systems 2020-08-04 Reetam Sen Biswas , Behrouz Azimian , Anamitra Pal

We consider the problem of identifying a single line outage in a power grid by using data from phasor measurement units (PMUs). When a line outage occurs, the voltage phasor of each bus node changes in response to the change in network…

Optimization and Control · Mathematics 2014-09-15 Taedong Kim , Stephen J. Wright

Physical security of power networks under power injection attacks that alter generation and loads is studied. The system operator employs Phasor Measurement Units (PMUs) for detecting such attacks, while attackers devise attacks that are…

Optimization and Control · Mathematics 2016-10-20 Yue Zhao , Andrea Goldsmith , H. Vincent Poor

The most commonly used weighted least square state estimator in power industry is nonlinear and formulated by using conventional measurements such as line flow and injection measurements. PMUs (Phasor Measurement Units) are gradually adding…

Systems and Control · Computer Science 2017-03-22 Hossein A. Sangrody , Mohammad Taghi Ameli

Diverse fault types, fast re-closures, and complicated transient states after a fault event make real-time fault location in power grids challenging. Existing localization techniques in this area rely on simplistic assumptions, such as…

Systems and Control · Computer Science 2019-05-20 Wenting Li , Deepjyoti Deka , Michael Chertkov , Meng Wang