Related papers: The DAMIC experiment at SNOLAB

200 papers

DAMIC (Dark Matter in CCDs) is a novel dark matter experiment that has unique sensitivity to dark matter particles with masses below 10 GeV. Due to its low electronic readout noise (R.M.S. ~3 e-) this instrument is able to reach a detection…

The DAMIC (Dark Matter in CCDs) experiment searches for the interactions of dark matter particles with the nuclei and the electrons in the silicon bulk of thick fully depleted charge-coupled devices (CCDs). Because of the low noise and low…

High Energy Physics - Experiment · Physics 2020-04-02 Mariangela Settimo

The DAMIC experiment uses fully depleted, high resistivity CCDs to search for dark matter particles. With an energy threshold $\sim$50 eV$_{ee}$, and excellent energy and spatial resolutions, the DAMIC CCDs are well-suited to identify and…

The DAMIC (Dark Matter in CCDs) experiment uses high resistivity, scientific grade CCDs to search for dark matter. The CCD's low electronic noise allows an unprecedently low energy threshold of a few tens of eV that make it possible to…

The DAMIC experiment employs large-area, thick charge-coupled devices (CCDs) to search for the interactions of low-mass dark matter particles in the galactic halo with silicon atoms in the CCD target. From 2017 to 2019, DAMIC collected data…

Cosmology and Nongalactic Astrophysics · Physics 2022-10-04 Alvaro E. Chavarria

Dark Matter In CCDs (DAMIC) is a silicon detector apparatus used primarily for searching for low-mass dark matter using the silicon bulk of Charge-Coupled Devices (CCDs) as targets. The silicon target within each CCD is…

Instrumentation and Detectors · Physics 2020-03-09 Steven Juhyung Lee , Ben Kilminster , Anna Macchiolo

The DAMIC-M (DArk Matter In CCDs at Modane) experiment will use skipper CCDs to search for low mass (sub-GeV) dark matter underground at the Laboratoire Souterrain de Modane (LSM) in France. With about 1 kg of silicon target mass and…

High Energy Physics - Experiment · Physics 2024-10-01 R. Smida

Experimental efforts of the last decades have been unsuccessful in detecting WIMPs (Weakly Interacting Massive Particles) in the 10-to-10$^4$ GeV/$c^2$ range, thus motivating the search for lighter dark matter. The DAMIC (DArk Matter In…

Cosmology and Nongalactic Astrophysics · Physics 2021-10-05 Michelangelo Traina

This report presents an overview of the unconventional use of charge-coupled devices (CCDs) to search for Dark Matter (DM). The DArk Matter In CCDs (DAMIC Experiment) employs the bulk silicon of thick, fully-depleted CCDs as a target for…

Instrumentation and Detectors · Physics 2020-01-14 N. Castello-Mor , DAMIC-M Collaboration

We present results of a dark matter search performed with a 0.6 kg day exposure of the DAMIC experiment at the SNOLAB underground laboratory. We measure the energy spectrum of ionization events in the bulk silicon of charge-coupled devices…

We construct the first comprehensive radioactive background model for a dark matter search with charge-coupled devices (CCDs). We leverage the well-characterized depth and energy resolution of the DAMIC at SNOLAB detector and a detailed…

The SuperCDMS Collaboration is currently building SuperCDMS SNOLAB, a dark matter search focused on nucleon-coupled dark matter in the 1-5 GeV/c$^2$ mass range. Looking to the future, the Collaboration has developed a set of…

Instrumentation and Detectors · Physics 2023-04-04 SuperCDMS Collaboration , M. F. Albakry , I. Alkhatib , D. W. P. Amaral , T. Aralis , T. Aramaki , I. J. Arnquist , I. Ataee Langroudy , E. Azadbakht , S. Banik , C. Bathurst , D. A. Bauer , R. Bhattacharyya , P. L. Brink , R. Bunker , B. Cabrera , R. Calkins , R. A. Cameron , C. Cartaro , D. G. Cerdeno , Y. -Y. Chang , M. Chaudhuri , R. Chen , N. Chott , J. Cooley , H. Coombes , J. Corbett , P. Cushman , F. De Brienne , S. Dharani , M. L. di Vacri , M. D. Diamond , E. Fascione , E. Figueroa-Feliciano , C. W. Fink , K. Fouts , M. Fritts , G. Gerbier , R. Germond , M. Ghaith , S. R. Golwala , J. Hall , N. Hassan , B. A. Hines , M. I. Hollister , Z. Hong , E. W. Hoppe , L. Hsu , M. E. Huber , V. Iyer , A. Jastram , V. K. S. Kashyap , M. H. Kelsey , A. Kubik , N. A. Kurinsky , R. E. Lawrence , M. Lee , A. Li , J. Liu , Y. Liu , B. Loer , P. Lukens , D. B. MacFarlane , R. Mahapatra , V. Mandic , N. Mast , A. J. Mayer , H. Meyer zu Theenhausen , E. Michaud , E. Michielin , N. Mirabolfathi , B. Mohanty , S. Nagorny , J. Nelson , H. Neog , V. Novati , J. L. Orrell , M. D. Osborne , S. M. Oser , W. A. Page , R. Partridge , D. S. Pedreros , R. Podviianiuk , F. Ponce , S. Poudel , A. Pradeep , M. Pyle , W. Rau , E. Reid , R. Ren , T. Reynolds , A. Roberts , A. E. Robinson , T. Saab , B. Sadoulet , I. Saikia , J. Sander , A. Sattari , B. Schmidt , R. W. Schnee , S. Scorza , B. Serfass , S. S. Poudel , D. J. Sincavage , C. Stanford , J. Street , H. Sun , F. K. Thasrawala , D. Toback , R. Underwood , S. Verma , A. N. Villano , B. von Krosigk , S. L. Watkins , O. Wen , Z. Williams , M. J. Wilson , J. Winchell , K. Wyko , S. Yellin , B. A. Young , T. C. Yu , B. Zatschler , S. Zatschler , A. Zaytsev , E. Zhang , L. Zheng , S. Zuber

We introduce the fully-depleted charge-coupled device (CCD) as a particle detector. We demonstrate its low energy threshold operation, capable of detecting ionizing energy depositions in a single pixel down to 50 eVee. We present results of…

We report direct-detection constraints on light dark matter particles interacting with electrons. The results are based on a method that exploits the extremely low levels of leakage current of the DAMIC detector at SNOLAB of…

We report constraints on sub-GeV dark matter particles interacting with electrons from the first underground operation of DAMIC-M detectors. The search is performed with an integrated exposure of 85.23 g days, and exploits the subelectron…

We report on a search for sub-GeV dark matter (DM) particles interacting with electrons using the DAMIC-M prototype detector at the Modane Underground Laboratory. The data feature a significantly lower detector single $e^-$ rate (factor 50)…

We present measurements of bulk radiocontaminants in the high-resistivity silicon CCDs from the DAMIC at SNOLAB experiment. We utilize the exquisite spatial resolution of CCDs to discriminate between $\alpha$ and $\beta$ decays, and to…