Related papers: Measurement of the $^{20}$F half-life
The half-life of $^{6}$He has been measured using a low energy radioactive beam implanted in a YAP scintillator and recording decay events in a 4$\pi$ geometry. Events were time-stamped with a digital data acquisition system enabling a…
Precise measurement of half-life of $^{212}$Po (one of the daughter nuclides in radioactive chain of $^{232}$Th) was realized by means of liquid scintillator based on toluene doped by complex of thorium and trioctylphosphine oxide with…
A high-precision half-life measurement for the superallowed Fermi $\beta^+$ emitter $^{22}$Mg was performed at the TRIUMF-ISAC facility using a 4$\pi$ proportional gas counter. The result of $T_{1/2} = 3.87400 \pm 0.00079$ s is a factor of…
A new measurement of the half-life of the positron emitter 10C has been made. The 10C decay belongs to the set of superallowed 0+ -> 0+ beta-decays whose Ft values offer stringent tests of the Conserved Vector Current (CVC) hypothesis and…
We have measured the half-life of $^{14}$O, a superallowed $(0^{+} \to 0^{+})$ $\beta$ decay isotope. The $^{14}$O was produced by the $^{12}$C($^{3}$He,n)$^{14}$O reaction using a carbon aerogel target. A low-energy ion beam of $^{14}$O…
The beta-decay half-life of 62Ga has been studied with high precision using on-line mass separated samples. The decay of 62Ga which is dominated by a 0+ to 0+ transition to the ground state of 62Zn yields a half-life of T_{1/2} = 116.19(4)…
The half-life of $^{212}$Po was measured with the highest up-to-date accuracy as $T_{1/2}=295.1(4)$ ns by using thorium-loaded liquid scintillator.
The $\frac{1}{2}^+ \rightarrow \frac{1}{2}^+$ superallowed mixed mirror decay of $^{19}$Ne to $^{19}$F is excellently suited for high precision studies of the weak interaction. However, there is some disagreement on the value of the…
The nuclide 18F disintegrates to 18O by beta+ emission (96.86%) and electron capture (3.14%) with a half-life of 1.8288 h. It is widely used in nuclear medicine for positron emission tomography (PET). Because of its short half-life this…
The half-life of $^{19}$Ne has been measured using a real-time digital multiparametric acquisition system providing an accurate time-stamp and relevant information on the detectors signals for each decay event. An exhaustive offline…
The literature half-life value of 65Ga is based on only one experiment carried out more than 60 years ago and it has a relatively large uncertainty. In the present work this half-life is determined based on the counting of the gamma-rays…
We report a precise determination of the 19Ne half-life to be $T_{1/2} = 17.262 \pm 0.007$ s. This result disagrees with the most recent precision measurements and is important for placing bounds on predicted right-handed interactions that…
The beta-decay half-life of 26Si was measured with a relative precision of 1.4*10e3. The measurement yields a value of 2.2283(27) s which is in good agreement with previous measurements but has a precision that is better by a factor of 4.…
Recently, Jenkins, Fischbach and collaborators have claimed evidence that radioactive half-lives vary systematically over a +/- 0.1% range as a function of the oscillating distance between the Earth and the Sun, based on multi-year activity…
The $\beta$-decay half-lives of $^{128\text{--}130}$Cd have been measured with the newly commissioned GRIFFIN $\gamma$-ray spectrometer at the TRIUMF-ISAC facility. The time structures of the most intense $\gamma$-rays emitted following the…
The half-life of the superallowed Fermi $\beta^+$ emitter $^{14}$O was determined to high precision via a direct $\beta$ counting experiment performed at the Isotope Separator and Accelerator (ISAC) facility at TRIUMF. The result,…
We perform coincidence measurements between $\alpha$ particles and $\gamma$ rays from a $^{233}$U source to determine the half-lives of the excited state in a $^{229}$Th nucleus. We first prove that the half-lives of 42.43- and 164.53-keV…
The half-life of 46V has been measured to be 422.66(6) ms, which is a factor of two more precise than the best previous measurement. Our result is also consistent with the previous measurements, with no repeat of the disagreement recently…
We have measured the half-life of the superallowed 0+ -to- 0+ beta+ emitter 26Si to be 2245.3(7) ms. We used pure sources of 26Si and employed a high-efficiency gas counter, which was sensitive to positrons from both this nuclide and its…
The lifetime of the Bs0 meson is measured using the semileptonic decay Bs0 --> Ds- l+ nu X. The data sample consists of about 110 pb^-1 of pp= collisions at sqrt{s} = 1.8 TeV collected by the CDF detector at Fermilab. Four different Ds-…