Infrared interferometers are optical devices that can measure optical path-length differences by measuring changes in the refractive index. Several arrangements can be deployed, from single channel devices to multichannel double color…
In this paper, we present our approach to systematically measure numerous performance parameters of MCP-PMTs. The experimental setups, the analyses and selected results are discussed. Although the techniques used may be different in other…
We present the development and characterization of a compact low-energy ion beam diagnostic for the WISArD (Weak Interaction Studies with $\mathrm{^{32}Ar}$ Decay) experiment at ISOLDE/CERN. The microchannel plate (MCP) detector, which is…
The ability to use coherent light for material science and applications is directly linked to our ability to measure short optical pulses. While free-space optical methods are well-established, achieving this on a chip would offer the…
We have developed a position response calibration method for a micro-channel plate (MCP) detector with a delay-line anode position readout scheme. Using an {\em in situ} calibration mask, an accuracy of 8~$\mu$m and a resolution of…
Image subtraction in astronomy is a tool for transient object discovery and characterization, particularly useful in wide fields, and is well suited for moving or photometrically varying objects such as asteroids, extra-solar planets and…
We propose and demonstrate experimentally a new method based on the spatial entanglement for the absolute calibration of analog detector. The idea consists on measuring the sub-shot-noise intensity correlation between two branches of…
The spatial dependence of the timing performance of the R3809U-50 Micro-Channel-Plate PMT (MCP-PMT) by Hamamatsu was studied in high energy muon beams. Particle position information is provided by a GEM tracker telescope, while timing is…
We present a novel method of calibration of crosstalk probability for multi-pixel photon counters (MPPCs) based on the measurement of the normalized second-order intensity correlation function of coherent light. The method was tested for…
In recent years, there has been a proliferation of wide-field sky surveys to search for a variety of transient objects. Using relatively short focal lengths, the optics of these systems produce undersampled stellar images often marred by a…
A systematic investigation of Planacon MCP-PMTs was performed using 64 XP85002/FIT-Q photosensors. These devices are equipped with microchannel plates of reduced resistance. Results of a study of their gain stability over time and…
Accurately measuring the translations of objects between images is essential in many fields, including biology, medicine, chemistry, and physics. One important application is tracking one or more particles by measuring their apparent…
One of the on-going issues with the use of microchannel plates (MCP) in the ionization profile monitors (IPM) at Fermilab is the significant decrease in gain over time. There are several possible issues that can cause this. Historically,…
We consider the two-dimensional multi-target detection problem of recovering a target image from a noisy measurement that contains multiple copies of the image, each randomly rotated and translated. Motivated by the structure reconstruction…
The Argonne micro-channel plate photomultiplier tube (MCP-PMT) is an offshoot of the Large Area Pico-second Photo Detector (LAPPD) project, wherein \mbox{6 $\times$ 6 cm$^2$} sized detectors are made at Argonne National Laboratory.…
In this paper we propose a modified cross correlation method to align images from the same class in single-particle electron microscopy of highly non-spherical structures. In this new method, First we coarsely align projection images, and…
The ultimate miniaturization of any optical system relies on the reduction or removal of free-space gaps between optical elements. Recently, nonlocal flat optic components named spaceplates were introduced to effectively compress space for…
We describe a high resolution imaging detector based on a single 80 mm micro-channel-plate (MCP) and a phosphor screen mounted on a UHV flange of only 100 mm inner diameter. It relies on standard components and we describe its performance…
The atomic layer deposition(ALD) coating lengthens the lifetime of microchannel plates(MCP), which are used as the electron amplifier of the photomultiplier tubes(PMT). In the Jinping Neutrino Experiment, the newly developed 8-inch MCP-PMT…
With the growing technology of photon-counting detectors (PCD), spectral CT is a widely concerned topic which has the potential of material differentiation. However, due to some non-ideal factors such as cross talk and pulse pile-up of the…