English
Related papers

Related papers: A Novel Electrical Method to Measure Wire Tensions…

200 papers

Noble liquid radiation detectors have long been afflicted by spurious electron emission from their cathodic electrodes. This phenomenon must be understood and mitigated in the next generation of liquid xenon (LXe) experiments searching for…

Instrumentation and Detectors · Physics 2018-08-29 A. Tomás , H. M. Araújo , A. J. Bailey , A. Bayer , E. Chen , B. López Paredes , T. J. Sumner

We measured unusual critical currents as functions of temperature in the zero field and as functions of a magnetic field perpendicular to the substrate surface at a given temperature close to the critical temperature in thin-film long…

Superconductivity · Physics 2026-05-01 V. I. Kuznetsov , O. V. Trofimov

We explore the thermoelectric properties of gold atomic chains bridging gold electrodes by means of \textit{ab initio} and semi-empirical calculations, and heuristic reasoning. We predict the thermoelectric voltage induced by a temperature…

Mesoscale and Nanoscale Physics · Physics 2018-09-28 Alireza Saffarzadeh , Firuz Demir , George Kirczenow

A high-sensitivity wireless pressure sensor with active processing structure designed on the dielectric substrate has been present and evaluated in this paper. The sensor configuration has been optimized by computer-aided design to achieve…

Instrumentation and Detectors · Physics 2024-11-27 Baiyun Wang , Yijia Cheng , Yujie Hua , Wenxuan Tang , Wei E. I. Sha , Hao Xu , Kang Wang , Jundi Hu , Huaqing Fan , Huanran Peng , Gang Shao

The half-size prototype of the multi wire drift chamber (MWDC) for the cooling storage ring (CSR) external-target experiment (CEE) was assembled and tested in 350 MeV/u Kr+Fe reactions on the heavy ion research facility in Lanzhou (HIRFL).…

We demonstrate a simple network-analyzer technique to make quantitative measurements of the bias dependence of spin torque in a magnetic tunnel junction. We apply a microwave current to exert an oscillating spin torque near the…

Mesoscale and Nanoscale Physics · Physics 2012-07-25 Lin Xue , Chen Wang , Yong-Tao Cui , J. A. Katine , R. A. Buhrman , D. C. Ralph

We theoretically propose a principle for precise measurement of oscillatory domain wall (DW) by a ferromagnetic Josephson junction, which is composed of a ferromagnetic wire with DW and two superconducting electrodes. The current-voltage…

Superconductivity · Physics 2012-04-12 Shin-ichi Hikino , Michiyasu Mori , Wataru Koshibae , Sadamichi Maekawa

Large detectors are often monitored at the channel level (drift time, collected charge, and hit maps), which validates hardware but not tracking performance. A wire-by-wire tracking efficiency diagnostic is presented for the Belle~II…

Instrumentation and Detectors · Physics 2026-05-19 Suryanarayan Mondal

Precise temperature monitoring -- to the level of a few milli-Kelvin -- is essential for the operation of large-scale cryostats requiring a recirculation system. In particular, the performance of Liquid Argon Time Projection Chambers --…

Instrumentation and Detectors · Physics 2025-06-09 Maria Antonova , Jordi Capó , Anselmo Cervera , Pablo Fernández , Miguel Á. García-Peris , Xavier Pons

The aim of this work is two-fold: to design devices for passive electric damping of structural vibrations by distributed piezoelectric transducers and electric networks, and to experimentally validate the effectiveness of such a damping…

Mathematical Physics · Physics 2010-07-13 F. dell'Isola , C. Maurini , M. Porfiri

Motivated by the prospects of increased measurement bandwidth, improved signal to noise ratio and access to the full complex magnetic susceptibility we develop a technique to extract microwave voltages from our high resistance (10…

Mesoscale and Nanoscale Physics · Physics 2012-11-07 D. Fang , T. Skinner , H. Kurebayashi , R. P. Campion , B. L. Gallagher , A. J. Ferguson

The ability to sensitively detect charges under ambient conditions would be a fascinating new tool benefitting a wide range of researchers across disciplines. However, most current techniques are limited to low-temperature methods like…

We describe a simple experiment for measuring the thermal expansion coefficient of a metal wire and discuss how the experiment can be used as a tool for exploring the interplay of measurement uncertainty and scientific models. In…

Classical Physics · Physics 2016-03-15 Dimitri R. Dounas-Frazer , Geoff Z. Iwata , Punit R. Gandhi

We show how the partition function of a network of parallel superconducting wires weakly coupled together by the proximity effect, subjected a vector potential along the wires can be mapped onto N-distinguishable two dimensional…

Superconductivity · Physics 2008-06-24 Kohjiro Kobayashi , David Stroud

Hybrid magnetic arrays embedded in superconducting films are ideal systems to study the competition between different physical (such as the coherence length) and structural length scales such as available in artificially produced…

We review here different methods to measure the bulk viscosity of complex fluids using micron-sized magnetic wires. The wires are characterized by length of a few microns and diameter of a few hundreds of nanometers. We first draw analogies…

Soft Condensed Matter · Physics 2021-09-27 Jean-Francois Berret

The spin-transfer torque from a DC spin-polarized current can generate highly-coherent magnetic precession in nanoscale magnetic-multilayer devices. By measuring linewidths of spectra from the resulting resistance oscillations, we argue…

Other Condensed Matter · Physics 2009-11-11 J. C. Sankey , I. N. Krivorotov , S. I. Kiselev , P. M. Braganca , N. C. Emley , R. A. Buhrman , D. C. Ralph

This paper presents an indirect method for measuring the switch terms of a vector network analyzer (VNA) using at least three reciprocal devices, which do not need to be characterized beforehand. This method is particularly suitable for…

Instrumentation and Detectors · Physics 2023-09-07 Ziad Hatab , Michael Ernst Gadringer , Wolfgang Bösch

An AC susceptometer operating in the range of 10 Hz to 100 kHz and at room temperature is designed, built, calibrated and used to characterize the magnetic behaviour of coated magnetic nanoparticles. Other weakly magnetic materials (in…

Instrumentation and Detectors · Physics 2013-12-18 M. Alderighi , G. Bevilacqua , V. Biancalana , Y. Dancheva , A. Khanbekyan , L. Moi

Dynamic conductance and time-of-flight current instability in a quantum wire connected to electron reservoirs under DC bias voltage are studied in the absence of a gate screening the Coulomb interaction of electrons. Due to a strong…

Mesoscale and Nanoscale Physics · Physics 2025-11-04 Bagun S. Shchamkhalova , Vladimir A. Sablikov