English
Related papers

Related papers: Phase-sensitive imaging of microwave currents in s…

200 papers

Weak measurement techniques have been extensively applied in the field of quantum precision measurement to detect ultra-small signals due to the amplification effect. In this work, we propose an optical detection system for a spin-exchange…

Instrumentation and Detectors · Physics 2025-08-19 Qian Cao , Liang Xu , Ziqian Yue , Jianqi Yang , Yueyang Zhai

Presented is a novel way to combine snapshot compressive imaging and lateral shearing interferometry in order to capture the spatio-spectral phase of an ultrashort laser pulse in a single shot. A deep unrolling algorithm is utilised for the…

Liquid-crystal microcavity lasers have attracted considerable attention because of their extraordinary tunability and sensitive response to external stimuli, and they operate generally within a specific phase. Here, we demonstrate a…

Particle beam microscopy uses a scanning beam of charged particles to create images of samples, and the quality of image reconstruction suffers when this beam current varies over time. Neither conventional reconstruction methods nor…

Image and Video Processing · Electrical Eng. & Systems 2021-06-10 Luisa Watkins

Computational imaging modalities support a simplification of the active architectures required in an imaging system and these approaches have been validated across the electromagnetic spectrum. Recent implementations have utilized…

Classical Physics · Physics 2016-08-24 Thomas Fromenteze , Xiaojun Liu , Michael Boyarsky , Jonah Gollub , David R. Smith

Phase microscopy is an invaluable tool in the biosciences and in clinical diagnostics. The sensitivity of current phase microscopy techniques is optimized for one specific mean phase value and varies significantly across a given sample.…

Optics · Physics 2019-08-30 Thomas Juffmann , Andrés de los Ríos Sommer , Sylvain Gigan

We report a new coherent imaging technique, termed ptychographic structured modulation (PSM), for quantitative super-resolution microscopy. In this technique, we place a thin diffuser (i.e., a scattering lens) in between the sample and the…

Image and Video Processing · Electrical Eng. & Systems 2019-07-26 Pengming Song , Shaowei Jiang , He Zhang , Zichao Bian , Chengfei Guo , Kazunori Hoshino , Guoan Zheng

We demonstrate a proof-of-principle magnetometer that relies on the active oscillation of a cold atom Raman laser to continuously map a field-sensitive atomic phase onto the phase of the radiated light. We demonstrate wideband sensitivity…

Atomic Physics · Physics 2015-06-11 Joshua M. Weiner , Kevin C. Cox , Justin G. Bohnet , Zilong Chen , James K. Thompson

Over the last two decades, spatial light modulators (SLMs) have revolutionised our ability to shape optical fields. They grant independent dynamic control over thousands of degrees-of-freedom within a single light beam. In this work we test…

A single-pixel digital holography system with phase-encoded illumination using a digital micromirror device (DMD) as a spatial light modulator (SLM) is presented. The enhanced switching rate of DMDs, far exceeding the stringent frame-rate…

The lensless endoscope (LE) is a promising device to acquire in vivo images at a cellular scale. The tiny size of the probe enables a deep exploration of the tissues. Lensless endoscopy with a multicore fiber (MCF) commonly uses a spatial…

Non-contact scanning probe microscopy (SPM) has developed into a powerful technique to image many different properties of samples. The conventional method involves monitoring the amplitude, phase or frequency of a cantilever oscillating at…

Mesoscale and Nanoscale Physics · Physics 2015-06-16 Manan Mehta , Venkat Chandrasekhar

A superconducting radio-frequency (SRF) photo injector is in operation at the electron linac for beams with high brilliance and low emittance (ELBE) radiation center and generates continuous wave (CW) electron beams with high average…

Accelerator Physics · Physics 2023-03-22 S. Ma , A. Arnold , P. Michel , P. Murcek , A. Ryzhov , J. Schaber , R. Steinbruck , P. Evtushenko , J. Teichert , W. Hillert , R. Xiang , J. Zhu

In traditional detection of the magnetic signal in the experiment, complicated electronic devices are usually set up to explore the feedback from the superconducting transition due to the external magnetic field. This kind of direct…

Superconductivity · Physics 2022-11-15 Ziyan Li , Mengbo Guo

Future wireless communication system embraces physical-layer signal detection with high sensitivity, especially in the microwave photon level. Currently, the receiver primarily adopts the signal detection based on semi-conductor devices for…

Signal Processing · Electrical Eng. & Systems 2020-06-26 Junyu Zhang , Chen Gong , Shangbin Li , Rui Ni , Chengjie Zuo , Jinkang Zhu , Ming Zhao , Zhengyuan Xu

Study of interaction between high absorption matter and microwave radiated energy is a subject of great importance. Especially, this concerns microwave spectroscopic characterization of biological liquids. Use of effective testing methods…

Optics · Physics 2015-06-24 G. Vaisman , E. O. Kamenetskii , R. Shavit

Low phase noise microwave oscillators are at the center of a multitude of applications that span the gamut of photonics and electronics. Within this space, optically-derived approaches to microwave frequency synthesis are particularly…

We report the development of the frequency-modulation (FM) method for measuring electron spin resonance (ESR) absorption in the 210-420 GHz frequency range. We demonstrate that using a high-frequency ESR spectrometer without resonating…

Strongly Correlated Electrons · Physics 2010-07-14 Balint Nafradi , Richard Gaal , Titusz Feher , Laszlo Forro

Line Intensity Mapping (LIM) is a new observational technique that uses low-resolution observations of line emission to efficiently trace the large-scale structure of the Universe out to high redshift. Common mm/sub-mm emission lines are…

A number of modern millimeter, sub-millimeter, and far-infrared detectors are read out using superconducting microwave (1-10GHz) resonators. The main detector technologies are Transition Edge Sensors, read out using Microwave SQUID…

Instrumentation and Detectors · Physics 2022-08-08 Max Silva-Feaver , Zeeshan Ahmed , Kam Arnold , Josef C. Frisch , John Groh , Shawn W. Henderson , Jesus Vasquez , Cyndia Yu