Related papers: Looking for Hidden Photon's Cold Dark Matter By Mu…
Here we present measurements of the rates of emission of single electrons from the cathode of a proportional counter filled with a mixture of Ar + CH4 (10%) at 1 bar. We interpret the results as a possible photoelectric effect associated…
The dark rate of single electrons emitted from a metal cathode of the counter depends upon a temperature. At cryogenic temperatures the dark rate measured with bi-alkaline cathodes of PMT has been found to increase by lowering the…
We report on a new technique of a Multi-Cathode Counter (MCC) developed to search for hidden photon (HP) cold dark matter (CDM) with a mass from 5 to 10 eV. The method suggested in the assumption that hidden photons of the mass greater than…
We report on a new technique of a Multi-Cathode Counter (MCC) developed to search for hidden photon (HP) cold dark matter (CDM) with a mass from 5 to 500 eV. The method is suggested in the assumption that HP-photon mixing causes emission of…
A search for hidden-photon (HP) dark matter using a multi-cathode counter is reported. The technique based on counting of single electrons emitted from outer cathode of the proportional counter by hidden-photons was used. The apparatus and…
We report on a new technique of a Multi-Cathode Counter (MCC) developed to search for hidden photon (HP) cold dark matter (CDM) with a mass from 5 to 500 eV. The method suggested in the assumption that hidden photons of the mass greater…
It was found that at cryogenic temperatures the spontaneous emission of single electrons from cathode of PMT is increased by lowering the temperature of PMT. This effect has not found yet a satisfactory explanation. It was suggested by us…
A search for hidden photon cold dark matter in a mass range from 5 to 500 eV in data collected during 60 days in November and December, 2015 by a Multi-Cathode Counter (MCC) is reported. From the analyses of this data we found no evidence…
The results of the experiment to search for hidden photons using a multi-cathode counter technique are presented. The new results of measurements using a counter filled with Ne + CH4 (10\%) are given. The analysis of the data obtained is…
New upper limit on a mixing parameter for hidden photons with a mass from 5 eV till 10 keV has been obtained from the results of measurements during 78 days in two configurations R1 and R2 of a multicathode counter. For a region of a…
The technique is described of the search for dark photons with a multicathode counter. The aim of experiment is to search for diurnal variations of the effect from conversion of dark photons at the surface of the metallic cathode. The…
The main points of experiment on the search of dark photons using multy-cathode counter are outlined. The evidence base to prove that the observed effect is really from dark photons is formulated. First data on diurnal variations are…
In this paper, we report the results obtained in the PHoton ELectron EXperiment (PHELEX) during 208 days of measurements in the search for dark photons using a multi-cathode counter with an iron cathode. We observed a systematic excess of…
A search for hidden photon cold dark matter (HP CDM) using a new technique with a dish antenna is reported. From the result of the measurement, we found no evidence for the existence of HP CDM and set an upper limit on the photon-HP mixing…
We report on a search for hidden photon cold dark matter (HP CDM) using a novel technique with a dish antenna. We constructed two independent apparatus: one is aiming at the detection of the HP with a mass of $\sim\,\rm{eV}$ which employs…
We point out that power measurements of single quasiparticle devices open a new avenue to detect dark matter (DM). The threshold of these devices is set by the Cooper pair binding energy, and is therefore so low that they can detect DM as…
The dark count rate of a multipixel photon counter (MPPC) was reduced to less than 0.2 cps by cooling the counter to 78.5 K. Characteristics of the MPPC other than the dark count rate were also detemined at 78.5 K and 295 K. The…
We search for the dark photon dark matter (DPDM) using a cryogenic millimeter-wave receiver. DPDM has a kinetic coupling with electromagnetic fields with a coupling constant of $\chi$, and is converted into ordinary photons at the surface…
In this paper we describe the apparatus used in this experiment and the procedure of data treatment. We give the latest experimental results and discuss the possibility to observe diurnal variations of the count rates due to rotation of the…
We search for hidden-photon cold dark matter (HP-CDM) using a spectroscopic system in a K-band frequency range. Our system comprises a planar metal plate and cryogenic receiver. This is the first time a cryogenic receiver has been used in…