Related papers: LLRF system for the Fermilab Muon g-2 and Mu2e pro…
Muon g-2 data can be used to study sidereal variation of anomalous muon precession rate, which is one of the important signatures of CPT and Lorentz invariance violation. The discussion in this proceeding will focus on the framework which…
The Mu2e experiment at Fermilab searches for the charged-lepton flavor violating neutrino-less conversion of a negative muon into an electron in the field of a aluminum nucleus. The dynamic of such a process is well modeled by a two-body…
The muon anomalous magnetic moment measurement has, for more than a decade, been a long-standing anomaly hinting the physics beyond the Standard Model (BSM). The recently announced results from muon $g-2$ collaboration, corresponding to…
We survey a new generation of precision muon lifetime experiments. The goal of the MuCap experiment is a determination of the rate for muon capture on the free proton to 1 percent, from which the induced pseudoscalar form factor $g_P$ of…
Muon acceleration from 30 to 750 GeV in 72 orbits using two rings in the 1000m radius Tevatron tunnel is explored. The first ring ramps at 400 Hz and accelerates muons from 30 to 400 GeV in 28 orbits using 14 GV of 1.3 GHz superconducting…
We summarize the current state of a concept for muon acceleration aimed at a future Neutrino Factory. The main thrust of these studies was to reduce the overall cost while maintaining performance by exploring the interplay between the…
The Muon g-2 experiment at Fermilab has published the first result on Run-1 dataset in 2021 showing a good agreement with the previous experimental result at Brookhaven National Laboratory at comparable precision (0.46 ppm). In August 2023…
The Muon g-2 experiment at FERMILAB has confirmed the muon anomalous magnetic moment anomaly with an error bar 15% smaller and a different central value compared with the previous Brookhaven result. The combined results from FERMILAB and…
The muon magnetic anomaly, $a_{\mu}=(g_{\mu}-2)/2$, plays a special role in the history of the Standard Model (SM). Precise calculations and measurements of this fundamental quantity provide a stringent test of the SM and a window to the…
The anomalous magnetic moment (g-2) of the muon was measured with a precision of 0.54 ppm in Experiment 821 at Brookhaven National Laboratory. A difference of 3.2 standard deviations between this experimental value and the prediction of the…
Charged lepton flavor violation (CLFV) is expected in a diverse set of new physics scenarios. The current generation of experiments probe CLFV in the muon sector in three complementary channels: $\mu^-N \rightarrow e^- N$ (Mu2e, COMET),…
The Proton Improvement Plan, Stage Two (PIP-II) is a program of upgrades proposed for the Fermilab injection complex, which central part is an 800 MeV, 2 mA CW SRF linac. A prototype of the PIP-II linac front end called PIP-II Injector Test…
A new experimental area designed to develop, test and verify muon ionization cooling apparatus using the 400-MeV Fermilab Linac proton beam has been fully installed and is presently being commissioned. Initially, this area was used for…
The muon has played a central role in establishing the Standard Model of particle physics, and continues to provide valuable information about the nature of new physics. A new complex at Fermilab, the Advanced Muon Facility, would provide…
We discuss the prospects of probing the $L_\mu - L_\tau$ gauge boson at the MUonE experiment. The $L_\mu - L_\tau$ gauge boson $Z^\prime$ with a mass of $\lesssim 200$ MeV, which can explain the discrepancy between the measured value of the…
PIP-II is a superconducting linac that is in the initial acceleration chain for the Fermilab accelerator complex. The RF system consists of a warm front-end with an RFQ and buncher cavities along with 25 superconducting cryo-modules…
The next generation of high-energy physics experiments requires high intensity protons in the multi-GeV energy range for efficient production of secondary beams. The Fermilab long-term future requires an 8 GeV proton source to feed the Main…
Fermi National Accelerator Laboratory is constructing an Advanced Accelerator Research and Development facility at New Muon Lab. The cryogenic infrastructure in support of the initial phase of the facility consists of two Tevatron style…
The muon-proton and muon-deuteron inclusive deep inelastic scattering cross sections were measured in the kinematic range 0.002 < x < 0.60 and 0.5 < Q2 < 75 GeV2 at incident muon energies of 90, 120, 200 and 280 GeV. These results are based…
The muon (g-2) experiment at BNL has completed four data runs for the positive muon, beginning in 1997 and has just finished its first run for the negative muon. Recently the analysis of a 1.3 ppm result based on the 1999 run was completed…