This paper describes the calibration procedure for the drift tubes of the CMS barrel muon system and reports the main results obtained with data collected during a high statistics cosmic ray data-taking period. The main goal of the…
We propose a method to exploit high finesse optical resonators for light assisted coherent manipulation of atomic ensembles, overcoming the limit imposed by the finite response time of the cavity. The key element of our scheme is to rapidly…
Statistical calibration where the curve is nonlinear is important in many areas, such as analytical chemistry and radiometry. Especially in radiometry, instrument characteristics change over time, thus calibration is a process that must be…
Iterative phase estimation has long been used in quantum computing to estimate Hamiltonian eigenvalues. This is done by applying many repetitions of the same fundamental simulation circuit to an initial state, and using statistical…
Computer model calibration is a crucial step in building a reliable computer model. In the face of massive physical observations, a fast estimation for the calibration parameters is urgently needed. To alleviate the computational burden, we…
Both, robot and hand-eye calibration haven been object to research for decades. While current approaches manage to precisely and robustly identify the parameters of a robot's kinematic model, they still rely on external devices, such as…
Antenna array calibration is necessary to maintain the high fidelity of beam patterns across a wide range of advanced antenna systems and to ensure channel reciprocity in time division duplexing schemes. Despite the continuous development…
Performing experiments on small-scale quantum computers is certainly a challenging endeavor. Many parameters need to be optimized to achieve high-fidelity operations. This can be done efficiently for operations acting on single qubits as…
The development of sensitive large format imaging arrays for the infrared promises to provide revolutionary capabilities for space astronomy. For example, the Infrared Array Camera (IRAC) on SIRTF will use four 256 x 256 arrays to provide…
Quantum sensors based on atom interferometers are advancing both fundamental physics and practical applications, with higher sensitivity being a key requirement for these investigations. Here, we experimentally demonstrate a sensitivity…
Characterizing the phase space distribution of particle beams in accelerators is a central part of accelerator understanding and performance optimization. However, conventional reconstruction-based techniques either use simplifying…
We consider the problem of controlling the motion of an atom trapped in an optical cavity using continuous feedback. In order to realize such a scheme experimentally, one must be able to perform state estimation of the atomic motion in real…
An international team is currently investigating the best way to use Higher Order Modes (HOM) for beam diagnostics in 3.9 GHz cavities. HOMs are excited by charged particles when passing through an accelerating structure. Third harmonic…
Although Neural Radiance Fields (NeRFs) have markedly improved novel view synthesis, accurate uncertainty quantification in their image predictions remains an open problem. The prevailing methods for estimating uncertainty, including the…
The development of laser cooling coupled with the ability to trap atoms and ions in electromagnetic fields, has revolutionised atomic and optical physics, leading to the development of atomic clocks, high-resolution spectroscopy and…
We describe a technique for measuring the complex reflectivity of an optical cavity with a resonant local oscillator laser and an auxiliary probe laser, each coupled via opposite ends of the cavity. A heterodyne sensing scheme is then used…
Beam measurement is very important for accelerators. With the development of analog-to-digital conversion techniques, digital beam measurement becomes a research hot spot. IQ (In-phase & Quadrature-phase) analysis based method is an…
Higher Order Modes (HOM) excited by the beam in the 3.9 GHz accelerating cavities in FLASH can be used for beam position diagnostics, as in a cavity beam position monitor. Previous studies of the modal choices within the complicated…
Adaptive (or deformable) mirrors are widely used as wavefront correctors in adaptive optics systems. The optical calibration of an adaptive mirror is a fundamental step during its life-cycle: the process is in facts required to compute a…
The main task of an energy calibration is to find a relation between pulse-height values and the corresponding energies. Doing this for each pulse-height channel individually requires an elaborated input spectrum with an excellent counting…