English
Related papers

Related papers: A micro-SQUID with dispersive readout for magnetic…

200 papers

We describe a dispersive nanoSQUID magnetometer comprised of two variable thickness aluminum weak-link Josephson junctions shunted in parallel with an on-chip capacitor. This arrangement forms a nonlinear oscillator with a tunable 4-8 GHz…

Mesoscale and Nanoscale Physics · Physics 2013-04-16 E. M. Levenson-Falk , R. Vijay , N. Antler , I. Siddiqi

We report on a scanned superconducting quantum interference device (SQUID) microscope operating in a cryogen-free cryostat, with the capability of up to forty RF connections with 20 GHz bandwidth to a device under test. The system utilizes…

Superconductivity · Physics 2025-09-10 Ian W. Haygood , Bochao Xu , John Biesecker , Michael L. Schneider

We developed a scanning DC SQUID microscope with novel readout electronics capable of wideband sensing RF magnetic fields from 50 to 200 MHz and simultaneously providing closed-loop response at kHz frequencies. To overcome the 20 MHz…

There is currently fundamental and technological interest in measuring and manipulating nanoscale magnets, particularly in the quantum coherent regime. To observe the dynamics of such systems one requires a magnetometer with not only…

Mesoscale and Nanoscale Physics · Physics 2015-05-18 M. Hatridge , R. Vijay , D. H. Slichter , J. Clarke , I. Siddiqi

We present experimental results on a dispersive scheme for reading out a Josephson phase qubit. A capacitively shunted dc-SQUID is used as a nonlinear resonator which is inductively coupled to the qubit. We detect the flux state of the…

Superconductivity · Physics 2015-05-20 T. Wirth , J. Lisenfeld , A. Lukashenko , A. V. Ustinov

We present measurements of an amplifier operating at 3.8 GHz with 150 MHz of bandwidth based on the microstrip input-coil resonance of a dc superconducting quantum interference device (SQUID) with submicron Josephson junctions. The noise…

Superconductivity · Physics 2015-06-05 M. P. DeFeo , B. L. T. Plourde

We investigated, at temperature $4.2\,\mathrm{K}$, electric transport, flux noise and resulting spin sensitivity of miniaturized Nb direct current superconducting quantum interference devices (SQUIDs) based on submicron Josephson junctions…

Superconductivity · Physics 2015-05-28 J. Nagel , O. F. Kieler , T. Weimann , R. Wölbing , J. Kohlmann , A. B. Zorin , R. Kleiner , D. Koelle , M. Kemmler

We report on the fabrication and characterization of microSQUID devices based on nanoscale vanadium/copper/vanadium Josephson weak links. Magnetically driven quantum interference patterns have been measured for temperatures in the 0.24 - 2…

Mesoscale and Nanoscale Physics · Physics 2013-09-06 Alberto Ronzani , Matthieu Baillergeau , Carles Altimiras , Francesco Giazotto

A flux qubit readout scheme involving a dispersive technique coupled to a microstrip squid amplifier has been tested experimentally. Thanks to the almost quantum limited noise of this amplifier at low temperature, this readout device is…

Superconductivity · Physics 2008-12-02 Sebastien Michotte

A superconducting flux qubit is inductively coupled to a Superconducting QUantum Interference Device (SQUID) magnetometer, capacitively shunted to form a 1.294-GHz resonator. The qubit-state-dependent resonator frequency is weakly probed…

Superconductivity · Physics 2012-03-07 J. E. Johnson , E. M. Hoskinson , C. Macklin , D. H. Slichter , I. Siddiqi , John Clarke

Superconducting quantum interference devices (SQUIDs) are exceptionally sensitive magnetometers capable of detecting weak magnetic fields. Miniaturizing these devices and integrating them onto scanning probes enables high-resolution imaging…

We present a new generation of a scanning MicroSQUID microscope operating in an inverted dilution refrigerator. The MicroSQUIDs have a size of 1.21$ \ \mu$m\textsuperscript{2} and a magnetic flux sensitivity of 120 $\mu\Phi_{0} /…

Superconducting QUantum Interference Device (SQUID) microscopy has excellent magnetic field sensitivity, but suffers from modest spatial resolution when compared with other scanning probes. This spatial resolution is determined by both the…

Scanning Superconducting Quantum Interference Device (SQUID) Susceptometry simultaneously images the local magnetic fields and susceptibilities above a sample with sub-micron spatial resolution. Further development of this technique…

Superconductivity · Physics 2020-01-01 Samantha I Davis , John R. Kirtley , Kathryn A. Moler

We report on the development of highly sensitive SQUIDs featuring sub-micrometer loop dimensions. The integration of high quality and low capacitance SIS Nb/AlOx/Nb cross-type Josephson tunnel junctions results in white flux noise levels as…

Superconductivity · Physics 2015-01-06 M. Schmelz , Y. Matsui , R. Stolz , V. Zakosarenko , T. Schönau , S. Anders , S. Linzen , H. Itozaki , H. -G. Meyer

We propose a generalisation of dispersive qubit readout which provides the time evolution of a flux qubit observable. Our proposal relies on the non-linear coupling of the qubit to a harmonic oscillator with high frequency, representing a…

Superconductivity · Physics 2011-09-15 Georg M. Reuther , David Zueco , Peter Hänggi , Sigmund Kohler

We describe a new type of scanning probe microscope based on a superconducting quantum interference device (SQUID) that resides on the apex of a sharp tip. The SQUID-on-tip is glued to a quartz tuning fork which allows scanning at a…

Superconductivity · Physics 2013-08-13 A. Finkler , D. Vasyukov , Y. Segev , L. Ne'eman , E. O. Lachman , M. L. Rappaport , Y. Myasoedov , E. Zeldov , M. E. Huber

We have developed and measured a high-gain quantum-limited microwave parametric amplifier based on a superconducting lumped LC resonator with the inductor L including an array of 8 superconducting quantum interference devices (SQUIDs). This…

Superconductivity · Physics 2015-06-22 X. Zhou , V. Schmitt , P. Bertet , D. Vion , W. Wustmann , V. Shumeiko , D. Esteve

We present an optimization study of the spin sensitivity of nanoSQUIDs based on resistively shunted grain boundary Josephson junctions. In addition the dc SQUIDs contain a narrow constriction onto which a small magnetic particle can be…

We present an optimization study of the spin sensitivity of nanoSQUIDs based on resistively shunted grain boundary Josephson junctions. In addition the dc SQUIDs contain a narrow constriction onto which a small magnetic particle can be…

‹ Prev 1 2 3 10 Next ›