Related papers: Vibration decoupling system for massive bolometers…
With the rising adoption of dry dilution refrigerators across scientific and industrial domains, there has been a pressing demand for highly efficient vibration decoupling systems capable of operation at cryogenic temperatures in order to…
Dry Dilution Refrigerators (DDR) based on pulse tube cryo-coolers have started to replace Wet Dilution Refrigerators (WDR) due to the ease and low cost of operation. However these advantages come at the cost of increased vibrations, induced…
We present the design and implementation of a mechanical low-pass filter vibration isolation used to reduce the vibrational noise in a cryogen-free dilution refrigerator operated at 10 mK, intended for scanning probe techniques. We discuss…
Cryogenic quantum sensing techniques are developing alongside the ever-increasing requirements for noiseless experimental environments. For instance, several groups have isolated internal system vibrations from cold heads in closed-cycle…
Cryogen-free low-temperature setups are becoming more prominent in experimental science due to their convenience and reliability, and concern about the increasing scarcity of helium as a natural resource. Despite not having any moving parts…
We measure the current noise of several cryogenic cables in a pulse tube based dilution refrigerator at frequencies between about 1~mHz and 50~kHz. We show that vibration-induced noise can be efficiently suppressed by using vacuum-insulated…
Vibrations in cryocoolers are a recurrent concern to the end user. They appear in different parts of the acoustic spectrum depending on the refrigerator type, Gifford McMahon or pulse-tube, and with a variable coupling strength to the…
A shift of paradigm to obtain (sub-)Kelvin environment is currently on-going with the democratization of cryogen-free cryocoolers, boosted by their easy-to-use and continuous operation without the need of liquid helium whose cost and…
This article presents an evaluation of off-the-shelf commercial accelerometers at the mixing chamber stage of a cryogen-free dilution refrigerator at temperatures down to 8 mK. In addition, we present results of radioassay of accelerometer…
The latest generation of cosmic microwave background (CMB) telescopes is searching for the undetected faint signature of gravitational waves from inflation in the polarized signal of the CMB. To achieve the unprecedented levels of…
This manuscript reports a set of acceleration measurements in the frequency range from 0 to 50 kHz performed at the mixing chamber plate (2 axes) and the top flange (3 axes) of a cryogen-free dilution refrigerator. Various configurations of…
We describe a liquid-cryogen free cryostat with ultra-low vibration levels which allows for continuous operation of a torsion balance at cryogenic temperatures. The apparatus uses a commercially available two-stage pulse-tube cooler and…
Pulse tube refrigerators are becoming more common, because they are cost efficient and demand less handling than conventional (wet) refrigerators. However, a downside of a pulse tube system is the vibration level at the cold-head, which is…
We experimentally demonstrated a new method for reducing the vibration of the cold stage of a cryocooler. Comparing the RMS amplitude with the case of no phase shift of the driving gas pressure between the two pairs, the longitudinal…
We present a procedure for the design and construction of a passive, multipole, mechanical high-stop vibration isolator. The isolator, consisting of a stack of metal disks connected by thin wires, attenuates frequencies in the kilohertz…
This paper reports the detailed noise characterization, investigation of various noise sources and its mitigation to improve the performance of a cryogenic bolometer detector. The noise spectrum has been measured for a sapphire bolometer…
Low-temperature scanning probe microscopes (SPMs) are critical for the study of quantum materials and quantum information science. Due to the rising costs of helium, cryogen-free cryostats have become increasingly desirable. However, they…
Mechanical vibrations in buildings are ubiquitous. Such vibrations limit the performance of sensitive instruments used, for example, for high-precision manufacturing, nanofabrication, metrology, medical systems, or microscopy. For improved…
Bolometers are phonon mediated detectors used in particle physics experiments to search for rare processes, such as neutrinoless double beta decay and dark matter interactions. They feature an excellent energy resolution, which is a few keV…
We have developed and tested a new way of coupling bolometric light detectors to scintillating crystal bolometers based upon simply resting the light detector on the crystal surface, held in position only by gravity. This straightforward…