English
Related papers

Related papers: Millimeter-Wave Polarimeters Using Kinetic Inducta…

200 papers

We present a concept for an imaging gamma-ray polarimeter operating from ~50 MeV to ~1 GeV. Such an instrument would be valuable for the study of high-energy pulsars, active galactic nuclei, supernova remnants, and gamma-ray bursts. The…

Astrophysics · Physics 2009-11-10 P. F. Bloser , S. D. Hunter , G. O. Depaola , F. Longo

Atomically thin crystals of transition metal dichalcogenides (TMDs) host excitons with strong binding energies and sizable light-matter interactions. Coupled to optical cavities, monolayer TMDs routinely reach the regime of strong…

The Ku-band Polarization Identifier (KUPID) will integrate a very low noise 12-18 GHz, correlation polarimeter onto the Crawford Hill seven meter, millimeter-wave antenna. The primary components of the polarimeter will be built at the…

Astrophysics · Physics 2015-06-24 J. O. Gundersen

As a Near-IR instrument to PRL's upcoming 2.5 m telescope, NISP is designed indigeniously at PRL to serve as a multifaceted instrument. Optical, Mechanical and Electronics subsystems are being designed and developed in-house at PRL. It will…

We present a multi-chroic kinetic inductance detector (KID) pixel design integrated with a broadband hierarchical phased-array antenna. Each low-frequency pixel consists of four high-frequency pixels. Four passbands are designed from 125 to…

Instrumentation and Methods for Astrophysics · Physics 2022-11-23 Shibo Shu , Andrew Beyer , Peter K. Day , Fabien Defrance , Jack Sayers , Sunil Golwala

We report on the optical characterization of the AlMn kinetic inductance detectors (KIDs) in development for use in the Next-generation Extended Wavelength-MUltiband Sub/millimeter Inductance Camera (NEW-MUSIC) on the Leighton Chajnantor…

The Low Energy Polarization Detector (LPD) is a key component of the next-generation large-scale Gamma-Ray Burst polarimeter, POLAR-2. It is designed for polarization observations of transient sources in the soft X-ray energy range with a…

Microwave Kinetic Inductance Detectors (MKIDs) have great potential for large very sensitive detector arrays for use in, for example, sub-mm imaging. Being intrinsically readout in the frequency domain, they are particularly suited for…

Instrumentation and Methods for Astrophysics · Physics 2009-03-16 S. J. C. Yates , A. M. Baryshev , J. J. A. Baselmans , B. Klein , R. Güsten

The energy resolution of a single photon counting Microwave Kinetic Inductance Detector (MKID) can be degraded by noise coming from the primary low temperature amplifier in the detector's readout system. Until recently, quantum limited…

We describe the design and performance of polarization selective antenna-coupled TES arrays that will be used in several upcoming Cosmic Microwave Background (CMB) experiments: SPIDER, BICEP-2/SPUD. The fully lithographic polarimeter arrays…

We develop a simple coordinate transformation which can be employed to compensate for the nonlinearity introduced by a Microwave Kinetic Inductance Detector's (MKID) homodyne readout scheme. This coordinate system is compared to the…

The ITER tokamak will be operating with 5 microwave diagnostic systems. While they rely on different physics, they share a common need: transmitting low and high power microwave in the range of 12 GHz to 1000 GHz(different bandwidths for…

LiteBIRD is the Cosmic Microwave Background (CMB) radiation polarization satellite mission led by ISAS/JAXA. The main scientific goal is to search for primordial gravitational wave signals generated from the inflation epoch of the Universe.…

We present the development of a machine learning based pipeline to fully automate the calibration of the frequency comb used to read out optical/IR Microwave Kinetic Inductance Detector (MKID) arrays. This process involves determining the…

Instrumentation and Methods for Astrophysics · Physics 2021-04-06 Neelay Fruitwala , Alex B Walter , John I Bailey , Rupert Dodkins , Benjamin A Mazin

We describe a space-borne, multi-band, multi-beam polarimeter aiming at a precise and accurate measurement of the polarization of the Cosmic Microwave Background. The instrument is optimized to be compatible with the strict budget…

Instrumentation and Methods for Astrophysics · Physics 2019-08-13 P. de Bernardis , P. A. R. Ade , J. J. A. Baselmans , E. S. Battistelli , A. Benoit , M. Bersanelli , A. Bideaud , M. Calvo , F. J. Casas , G. Castellano , A. Catalano , I. Charles , I. Colantoni , F. Columbro , A. Coppolecchia , M. Crook , G. D'Alessandro , M. De Petris , J. Delabrouille , S. Doyle , C. Franceschet , A. Gomez , J. Goupy , S. Hanany , M. Hills , L. Lamagna , J. Macias-Perez , B. Maffei , S. Martin , E. Martinez-Gonzalez , S. Masi , D. McCarthy , A. Mennella , A. Monfardini , F. Noviello , A. Paiella , F. Piacentini , M. Piat , G. Pisano , G. Signorelli , C. Y. Tan , A. Tartari , N. Trappe , S. Triqueneaux , C. Tucker , G. Vermeulen , K. Young , M. Zannoni , A. Achúcarro , R. Allison , M. Ashdown , M. Ballardini , A. J. Banday , R. Banerji , J. Bartlett , N. Bartolo , S. Basak , A. Bonaldi , M. Bonato , J. Borrill , F. Bouchet , F. Boulanger , T. Brinckmann , M. Bucher , C. Burigana , A. Buzzelli , Z. Y. Cai , C. S. Carvalho , A. Challinor , J. Chluba , S. Clesse , G. De Gasperis , G. De Zotti , E. Di Valentino , J. M. Diego , J. Errard , S. Feeney , R. Fernandez-Cobos , F. Finelli , F. Forastieri , S. Galli , R. Génova-Santos , M. Gerbino , J. González-Nuevo , S. Hagstotz , J. Greenslade , W. Handley , C. Hernández-Monteagudo , C. Hervias-Caimapo , E. Hivon , K. Kiiveri , T. Kisner , T. Kitching , M. Kunz , H. Kurki-Suonio , A. Lasenby , M. Lattanzi , J. Lesgourgues , A. Lewis , M. Liguori , V. Lindholm , G. Luzzi , C. J. A. P. Martins , A. Melchiorri , J. B. Melin , D. Molinari , P. Natoli , M. Negrello , A. Notari , D. Paoletti , G. Patanchon , L. Polastri , G. Polenta , A. Pollo , V. Poulin , M. Quartin , M. Remazeilles , M. Roman , J. A. Rubiño-Martín , L. Salvati , M. Tomasi , D. Tramonte , T. Trombetti , J. Väliviita , R. Van de Weijgaert , B. van Tent , V. Vennin , P. Vielva , N. Vittorio

The W-Band ($75-110\; \mathrm{GHz}$) sky contains a plethora of information about star formation, galaxy evolution and the cosmic microwave background. We have designed and fabricated a dual-purpose superconducting circuit to facilitate the…

Instrumentation and Methods for Astrophysics · Physics 2017-11-01 George Che , Samuel Gordon , Peter Day , Christopher Groppi , Rebecca Jackson , Hamdi Mani , Philip Mauskopf , Harshad Surdi , Georgios Trichopoulos , Matthew Underhill

A Compton camera is the most promising approach for gamma-ray detection in the energy region from several hundred keV to MeV, especially for application in high energy astrophysics. In order to obtain good angular resolution, semiconductor…

We demonstrate strong negative electrothermal feedback accelerating and linearizing the response of a thermal kinetic inductance detector (TKID). TKIDs are a proposed highly multiplexable replacement to transition-edge sensors and measure…

The Balloon Experiment for Galactic INfrared Science (BEGINS) is a concept for a sub-orbital observatory that will operate from $\lambda$ = 25-250 $\mu$m to characterize dust in the vicinity of high-mass stars. The mission's sensitivity…

Instrumentation and Methods for Astrophysics · Physics 2024-01-01 Joanna Perido , Peter K. Day , Andrew D. Beyer , Nicholas F. Cothard , Steven Hailey-Dunsheath , Henry G. Leduc , Byeong H. Eom , Jason Glenn

LiteBIRD is a space-borne experiment dedicated to detecting large-scale $B$-mode anisotropies in the linear polarization of the Cosmic Microwave Background (CMB) predicted by the theory of inflation. It is planned to be launched in the late…

Instrumentation and Methods for Astrophysics · Physics 2022-09-27 Mayu Tominaga , Masahiro Tsujimoto , Graeme Smecher , Hirokazu Ishino