A metallic double-dot is measured with radio frequency reflectometry. Changes in the total electron number of the double-dot are determined via single electron tunnelling contributions to the complex electrical impedance. Electron counting…
The dark rate of single electrons emitted from a metal cathode of the counter depends upon a temperature. At cryogenic temperatures the dark rate measured with bi-alkaline cathodes of PMT has been found to increase by lowering the…
The dark rate of single-electrons emitted from a cathode of a multi-cathode counter may be interpreted as the effect from Hidden Photons (HPs) of Cold Dark Matter (CDM). As a tentative approach the measurements have been performed at…
The performance of a two-phase Ar avalanche detector in a single electron counting mode was studied, with regard to potential application in coherent neutrino-nucleus scattering and dark matter search experiments. The detector comprised of…
We report on a new technique of a Multi-Cathode Counter (MCC) developed to search for hidden photon (HP) cold dark matter (CDM) with a mass from 5 to 10 eV. The method suggested in the assumption that hidden photons of the mass greater than…
A calorimeter was built to measure the heat from a porous capacitive working electrode connected in a three-electrode configuration. This makes it possible to detect differences between cathodic and anodic heat production. The…
It was found that at cryogenic temperatures the spontaneous emission of single electrons from cathode of PMT is increased by lowering the temperature of PMT. This effect has not found yet a satisfactory explanation. It was suggested by us…
We use time-resolved charge detection techniques to investigate single-electron tunneling in semiconductor quantum dots. The ability to detect individual charges in real-time makes it possible to count electrons one-by-one as they pass…
The method of extraction of the e/h ratio for an electromagnetic compartment of a combined calorimeter is suggested and the non-compensation was determined. The results agree with the Monte Carlo prediction and results of the weighting…
We report on a new technique of a Multi-Cathode Counter (MCC) developed to search for hidden photon (HP) cold dark matter (CDM) with a mass from 5 to 500 eV. The method suggested in the assumption that hidden photons of the mass greater…
GEM are widely used as amplification stages in gaseous detectors exposed to high rates. The GEM consists of a polyimide foil which is coated by two thin copper layers. Charges collected into the holes or created during the amplification…
The Gas Electron Multiplier detectors with wire and metallic electrodes, with a gas filling in the gap between them were proposed and tested. The main advantage of these Gas Electron Multipliers compared to standard ones consists in their…
We experimentally investigate a scheme for detecting single atoms magnetically trapped on an atom chip. The detector is based on the photoionization of atoms and the subsequent detection of the generated ions. We describe the…
The gain measurements of several 1 mm-thick, 10$\times$10 cm$^2$ Thick Gaseous Electron Multipliers (ThGEMs), operated in pure argon at 3.3 bar and room temperature are presented. Electrostatic simulations, performed with the COMSOL…
We report on a new technique of a Multi-Cathode Counter (MCC) developed to search for hidden photon (HP) cold dark matter (CDM) with a mass from 5 to 500 eV. The method is suggested in the assumption that HP-photon mixing causes emission of…
We measured the properties of a novel combination of two Gas Electron Multipliers with a Micromegas for use as amplification devices in high-rate gaseous time projection chambers. The goal of this design is to minimize the buildup of space…
A novel readout architecture that uses multiple non-destructive floating-gate amplifiers to achieve sub-electron readout noise in a thick, fully-depleted silicon detector is presented. This Multi-Amplifier Sensing Charge-Coupled Device…
We have developed a new design of a GEM-like detector with single-layer electrodes made of a resistive kapton. This detector can operate at gains close to 10E5 even in pure Ar and Ne and if transited to discharges at higher gains they, due…
Owing to a few unique advantages, double-dot single electron transistor has been proposed as an alternative detector for charge states. In this work, we present a further study for its signal-to-noise property, based on a full analysis of…
EMCCDs are efficient imaging devices for low surface brightness UV astronomy from space. The large amplification allows photon counting, the detection of events versus non-events. This paper provides the statistics of the observation…