English
Related papers

Related papers: Towards commissioning the Fermilab Muon G-2 Experi…

200 papers

The upcoming muon (g-2) experiment at Fermilab will measure the anomalous magnetic moment of the muon to a relative precision of 140 ppb, 4 times better than the previous experiment at BNL. The new experiment is motivated by the persistent…

Instrumentation and Detectors · Physics 2015-04-07 J. Kaspar

The new g-2 experiment at Fermilab aims to measure the muon anomalous magnetic moment by a fourfold improvement in precision compared to the BNL experiment. Achieving this goal requires the delivery of highly polarized 3.094 GeV/c muons…

The Muon g-2 Experiment (E989) at Fermilab is seeking to measure the anomalous magnetic moment of muon ($a_{\mu}$) with a precision of 140 parts-per-billion (ppb) and aiming to resolve the discrepancy between the E821 measurement and the…

Instrumentation and Detectors · Physics 2018-10-10 Ran Hong

The Muon g-2 experiment at Fermilab will measure the anomalous magnetic moment of the muon to a precision of 140 parts per billion, which is a factor of four improvement over the previous E821 measurement at Brookhaven. The experiment will…

High Energy Physics - Experiment · Physics 2018-07-01 J. L. Holzbauer

The Fermilab Muon Campus will host the Muon g-2 experiment - a world class experiment dedicated to the search for signals of new physics. Strict demands are placed on beam diagnostics in order to ensure delivery of high quality beams to the…

Accelerator Physics · Physics 2017-09-19 D. Stratakis , B. Drendel , M. J. Syphers

The current $\sim3.5\sigma$ discrepancy between the experimental measurement and theoretical prediction of the muon magnetic anomaly, $a_{\mu}$, stands as a potential indication of the existence of new physics. The Muon $g-2$ experiment at…

High Energy Physics - Experiment · Physics 2019-07-24 Alexander Keshavarzi

The Muon g-2 Experiment at Fermilab will measure the anomalous magnetic moment of the muon to a precision of 140 parts per billion, which is a factor of four improvement over the previous E821 measurement at Brookhaven. The experiment will…

Instrumentation and Detectors · Physics 2017-01-04 J. L. Holzbauer

The Muon g-2 experiment at Fermilab, with the aim to measure the muon anomalous magnetic moment to an unprecedented level of 140~ppb, has started beam and detector commissioning in Summer 2017. To deal with incoming data projected to be…

Instrumentation and Detectors · Physics 2019-08-14 Kim Siang Khaw

The muon anomalous magnetic moment, $a_\mu = (g-2)/2$, is a low-energy observable which can be both measured and computed with very high precision, making it an excellent test of the Standard Model (SM) and a sensitive probe of new physics.…

High Energy Physics - Experiment · Physics 2022-07-20 Paolo Girotti

Fermilab is dedicated to hosting world-class experiments in search of new physics that will operate in the coming years. The Muon g-2 Experiment is one such experiment that will determine with unprecedented precision the muon anomalous…

I report on the progress of two new muon anomalous magnetic moment experiments, which are in advanced design and construction phases. The goal of Fermilab E989 is to reduce the experimental uncertainty of $a_\mu$ from Brookhaven E821 by a…

High Energy Physics - Experiment · Physics 2016-06-22 David W. Hertzog

The muon anomalous magnetic moment, $a_\mu=\frac{g-2}{2}$, is a low-energy observable which can be both measured and computed to high precision, making it a sensitive test of the Standard Model and a probe for new physics. This anomaly was…

High Energy Physics - Experiment · Physics 2025-03-13 Matteo Sorbara

This article reviews the muon g-2 experiment, a cornerstone in precision tests of the Standard Model of particle physics. The experiment measures the anomalous magnetic moment of the muon with unprecedented accuracy, seeking potential…

High Energy Physics - Experiment · Physics 2025-08-06 Marin Karuza

The Muon $g-2$ experiment at Fermilab aims to measure the muon anomalous magnetic moment with an unprecedented precision of 140 parts per billion (ppb). Data collection concluded in June 2023, and analysis of the largest dataset (2021-2023)…

High Energy Physics - Experiment · Physics 2024-12-25 On Kim

The upcoming Fermilab E989 experiment will measure the muon anomalous magnetic moment $a_{\mu}$ . This measurement is motivated by the previous measurement performed in 2001 by the BNL E821 experiment that reported a 3-4 standard deviation…

Instrumentation and Detectors · Physics 2017-04-05 Antoine Chapelain

A precision measurement of the muon anomalous magnetic moment, $a_{\mu} = (g-2)/2$, was previously performed at BNL with a result of 2.2 - 2.7 standard deviations above the Standard Model (SM) theoretical calculations. The same experimental…

Accelerator Physics · Physics 2013-01-30 C. Yoshikawa , A. Leveling , N. V. Mokhov , J. Morgan , D. Neuffer , S. Striganov

The Muon g-2 experiment at Fermilab seeks to measure the muon magnetic moment anomaly, $a_\mu =(g-2)/2$, with a final target precision of 0.14 parts-per-million (ppm). The experiment's initial result, published in 2021 using Run 1 data from…

High Energy Physics - Experiment · Physics 2025-06-27 Estifa'a Zaid

Since its discovery, the muon has proven to be an invaluable probe of the Standard Model (SM). Muons are readily available in tertiary beams in facilities around the world. They do not decay hadronically and have a lifetime of a few $\mu$…

High Energy Physics - Experiment · Physics 2025-02-04 Sophie Middleton

The Muon (g-2) Experiment, E989 at Fermilab, will measure the muon anomalous magnetic moment a factor-of-four more precisely than was done in E821 at the Brookhaven National Laboratory AGS. The E821 result appears to be greater than the…

Instrumentation and Detectors · Physics 2018-05-15 J. Grange , V. Guarino , P. Winter , K. Wood , H. Zhao , R. M. Carey , D. Gastler , E. Hazen , N. Kinnaird , J. P. Miller , J. Mott , B. L. Roberts , J. Benante , J. Crnkovic , W. M. Morse , H. Sayed , V. Tishchenko , V. P. Druzhinin , B. I. Khazin , I. A. Koop , I. Logashenko , Y. M. Shatunov , E. Solodov , M. Korostelev , D. Newton , A. Wolski , A. Chapelain , R. Bjorkquist , N. Eggert , A. Frankenthal , L. Gibbons , S. Kim , A. Mikhailichenko , Y. Orlov , D. Rubin , D. Sweigart , D. Allspach , G. Annala , E. Barzi , K. Bourland , G. Brown , B. C. K. Casey , S. Chappa , M. E. Convery , B. Drendel , H. Friedsam , T. Gadfort , K. Hardin , S. Hawke , S. Hayes , W. Jaskierny , C. Johnstone , J. Johnstone , V. Kashikhin , C. Kendziora , B. Kiburg , A. Klebaner , I. Kourbanis , J. Kyle , N. Larson , A. Leveling , A. L. Lyon , D. Markley , D. McArthur , K. W. Merritt , N. Mokhov , J. P. Morgan , H. Nguyen , J-F. Ostiguy , A. Para , C. C. Polly M. Popovic , E. Ramberg , M. Rominsky , D. Schoo , R. Schultz , D. Still , A. K. Soha , S. Strigonov , G. Tassotto , D. Turrioni , E. Villegas , E. Voirin , G. Velev , L. Welty-Rieger , D. Wolff , C. Worel , J-Y. Wu , R. Zifko , K. Jungmann , C. J. G. Onderwater , P. T. Debevec , S. Ganguly , M. Kasten , S. Leo , K. Pitts , C. Schlesier , M. Gaisser , S. Haciomeroglu , Y-I. Kim , S. Lee , M-J Lee , Y. K. Semertzidis , K. Giovanetti , V. A. Baranov , V. N. Duginov , N. V. Khomutov , V. A. Krylov , N. A. Kuchinskiy , V. P. Volnykh , C. Crawford , R. Fatemi , W. P. Gohn , T. P. Gorringe , W. Korsch , B. Plaster , A. Anastasi , D. Babusci , S. Dabagov , C. Ferrari , A. Fioretti , C. Gabbanini , D. Hampai , A. Palladino , G. Venanzoni , T. Bowcock , J. Carroll , B. King , S. Maxfield , K. McCormick , J. Price , D. Sim , A. Smith , T. Teubner , W. Turner , M. Whitley , M. Wormald , R. Chislett , S. Kilani , M. Lancaster , E. Motuk , T. Stuttard , M. Warren , D. Flay , D. Kawall , Z. Meadows , T. Chupp , R. Raymond , A. Tewlsey-Booth , M. J. Syphers , D. Tarazona , S. Catalonotti , R. Di Stefano , M. Iacovacci , S. Mastroianni , S. Chattopadhyay , M. Eads , M. Fortner , D. Hedin , N. Pohlman , A. de Gouvea , H. Schellman , L. Welty-Rieger , F. Azfar , S. Henry , G. D. Alkhazov , V. L. Golovtsov , P. V. Neustroev , L. N. Uvarov , A. A. Vasilyev , A. A. Vorobyov , M. B. Zhalov , L. Cerrito , F. Gray , G. Di Sciascio , D. Moricciani , C. Fu , X. Ji , L. Li , H. Yang , D. Stöckinger , G. Cantatore , D. Cauz , M. Karuza , G. Pauletta , L. Santi , S. Baeßler , M. Bychkov , E. Frlez , D. Pocanic , L. P. Alonzi , M. Fertl , A. Fienberg , N. Froemming , A. Garcia , D. W. Hertzog J. Kaspar , P. Kammel , R. Osofsky , M. Smith , E. Swanson , T. van Wechel , K. Lynch

The $g-2$ experiment successfully completed its second data taking period (Run-2) between March and July 2019, with the analysis of Run-1 and Run-2 data currently proceeding. The final goal of the experiment is to determine the muon…

Instrumentation and Detectors · Physics 2019-10-02 Gleb Lukicov
‹ Prev 1 2 3 10 Next ›