English
Related papers

Related papers: Enhancing Compressed Sensing 4D Photoacoustic Tomo…

200 papers

Photoacoustic tomography (PAT) is a newly developed medical imaging modality, which combines the advantages of pure optical imaging and ultrasound imaging, owning both high optical contrast and deep penetration depth. Very recently, PAT is…

Medical Physics · Physics 2021-09-21 Tengbo Lyu , Jiadong Zhang , Zijian Gao , Changchun Yang , Feng Gao , Fei Gao

Purpose: Photoacoustic tomography (PAT) is a novel imaging technique that can spatially resolve both morphological and functional tissue properties, such as the vessel topology and tissue oxygenation. While this capacity makes PAT a…

In photoacoustic tomography (PAT), a hybrid imaging modality that is based on the acoustic detection of optical absorption from biological tissue exposed to a pulsed laser, a short pulse laser generates an initial pressure proportional to…

Numerical Analysis · Mathematics 2026-03-27 Sunghwan Moon , Anwesa Dey , Souvik Roy

Photoacoustic computed tomography (PACT) is a hybrid imaging modality, which combines the high optical contrast of pure optical imaging and the high penetration depth of ultrasound imaging. However, photoacoustic image dataset with good…

Medical Physics · Physics 2022-05-24 Tengbo Lyu , Changchun Yang , Jiadong Zhang , Shanshan Guo , Feng Gao , Fei Gao

Photoacoustic computed tomography (PACT) is an emerging computed imaging modality that exploits optical contrast and ultrasonic detection principles to form images of the absorbed optical energy density within tissue. When the imaging…

Medical Physics · Physics 2016-11-15 Qiwei Sheng , Kun Wang , Thomas P. Matthews , Jun Xia , Liren Zhu , Lihong V. Wang , Mark A. Anastasio

Photoacoustic tomography is an emerging medical imaging technology whose primary aim is to map the high-contrast optical properties of biological tissues by leveraging high-resolution ultrasound measurements. Mathematically, this can be…

Analysis of PDEs · Mathematics 2025-02-14 Alessandro Felisi

Photoacoustic computed tomography (PACT) is an emerging computed imaging modality that exploits optical contrast and ultrasonic detection principles to form images of the absorbed optical energy density within tissue. If the object…

Medical Physics · Physics 2017-09-08 Joemini Poudel , Thomas P. Matthews , Lei Li , Mark A. Anastasio , Lihong V. Wang

In deep tissue photoacoustic imaging the spatial resolution is inherently limited by the acoustic wavelength. Recently, it was demonstrated that it is possible to surpass the acoustic diffraction limit by analyzing fluctuations in a set of…

Parametric images provide insight into the spatial distribution of physiological parameters, but they are often extremely noisy, due to low SNR of tomographic data. Direct estimation from projections allows accurate noise modeling,…

Photoacoustic tomography (PAT) is a non-invasive imaging modality that requires recovering the initial data of the wave equation from certain measurements of the solution outside the object. In the standard PAT measurement setup, the used…

Analysis of PDEs · Mathematics 2021-12-07 Linh V. Nguyen , Markus Haltmeier , Richard Kowar , Ngoc Do

Significance: Dynamic photoacoustic computed tomography (PACT) is a valuable technique for monitoring physiological processes. However, current dynamic PACT techniques are often limited to 2D spatial imaging. While volumetric PACT imagers…

Signal Processing · Electrical Eng. & Systems 2023-10-03 Refik M. Cam , Chao Wang , Weylan Thompson , Sergey A. Ermilov , Mark A. Anastasio , Umberto Villa

Photoacoustic tomography seeks to reconstruct an acoustic initial pressure distribution from the measurement of the ultrasound waveforms. Conventional methods assume a-prior knowledge of the sound speed distribution, which practically is…

Image and Video Processing · Electrical Eng. & Systems 2019-09-16 Hongming Shan , Christopher Wiedeman , Ge Wang , Yang Yang

Here we show that compressive sensing allow 4-dimensional (4-D) STEM data to be obtained and accurately reconstructed with both high-speed and low fluence. The methodology needed to achieve these results compared to conventional 4-D…

Photoacoustic microscopy (PAM) is a novel implementation of photoacoustic imaging (PAI) for visualizing the 3D bio-structure, which is realized by raster scanning of the tissue. However, as three involved critical imaging parameters,…

Image and Video Processing · Electrical Eng. & Systems 2023-08-10 Zhengyuan Zhang , Haoran Jin , Zesheng Zheng , Wenwen Zhang , Wenhao Lu , Feng Qin , Arunima Sharma , Manojit Pramanik , Yuanjin Zheng

Transcranial photoacoustic computed tomography (PACT) is an emerging neuroimaging modality, but skull-induced aberrations can result in severe image artifacts if not compensated for during image reconstruction. The development of advanced…

We address the problem of reconstructing high quality images from undersampled MRI data. This is a challenging task due to the highly ill-posed nature of the problem. In particular, in dynamic MRI scans, the interaction between the target…

Computer Vision and Pattern Recognition · Computer Science 2020-04-10 Angelica I. Aviles-Rivero , Noémie Debroux , Guy Williams , Martin J. Graves , Carola-Bibiane Schonlieb

In most photoacoustic (PA) measurements, variations in speed-of-sound (SOS) of the subject are neglected under the assumption of acoustic homogeneity. Biological tissue with spatially heterogeneous SOS cannot be accurately reconstructed…

Photoacoustic tomography (PAT) is a rapidly-evolving medical imaging modality that combines optical absorption contrast with ultrasound imaging depth. One challenge in PAT is image reconstruction with inadequate acoustic signals due to…

Motion, e.g., due to patient movement or improper device calibration, is inevitable in many imaging modalities such as photoacoustic tomography (PAT) by a rotating system and can lead to undesirable motion artifacts in image…

Numerical Analysis · Mathematics 2016-09-28 Julianne Chung , Linh Nguyen

The development of fast and accurate image reconstruction algorithms is a central aspect of computed tomography. In this paper, we investigate this issue for the sparse data problem in photoacoustic tomography (PAT). We develop a direct and…

Computer Vision and Pattern Recognition · Computer Science 2018-08-31 Stephan Antholzer , Markus Haltmeier , Johannes Schwab