Related papers: Double Minimum Variance Beamforming Method to Enha…
To address practical challenges in establishing and maintaining robust wireless connectivity such as multi-path effects, low latency, size reduction, and high data rate, the digital beamformer is performed by the hybrid antenna array at the…
Removing speckle noise from medical ultrasound images while preserving image features without introducing artifact and distortion is a major challenge in ultrasound image restoration. In this paper, we propose a multiframe-based adaptive…
This paper derives the analytical solution of a novel distributed node-specific block-diagonal linearly constrained minimum variance beamformer from the centralized linearly constrained minimum variance (LCMV) beamformer when considering…
In linear-array transducer based photoacoustic (PA) imaging, B-scan PA images are formed using the raw channel PA signals. Delay-and-Sum (DAS) is the most prevalent algorithm due to its simple implementation, but it leads to low quality…
Ultrasound imaging is a real-time diagnostic modality that reconstructs acoustic signals into visual representations of internal body structures. A key component in this process is beamforming, with the Delay and Sum (DAS) algorithm being a…
Millimeter wave (mmWave) full-duplex (FD) is a promising technique for improving capacity by maximizing the utilization of both time and the rich mmWave frequency resources. Still, it has restrictions due to FD self-interference (SI) and…
This work demonstrates a novel, state of the art method to reconstruct colored images via the Dynamic Vision Sensor (DVS). The DVS is an image sensor that indicates only a binary change in brightness, with no information about the captured…
Photoacoustic microscopy is becoming an important tool for the biomedical research. It has been widely used in biological researches, such as structural imaging of vasculature, brain structural and functional imaging, and tumor detection.…
One primary technical challenge in photoacoustic microscopy (PAM) is the necessary compromise between spatial resolution and imaging speed. In this study, we propose a novel application of deep learning principles to reconstruct…
Accelerating compute intensive non-real-time beam-forming algorithms in ultrasound imaging using deep learning architectures has been gaining momentum in the recent past. Nonetheless, the complexity of the state-of-the-art deep learning…
This paper considers a lens antenna array-assisted millimeter wave (mmWave) multiuser multiple-input multiple-output (MU-MIMO) system. The base station's beam selection matrix and user terminals' phase-only beamformers are jointly designed…
Distortion resulting from acoustic echo suppression (AES) is a common issue in full-duplex communication. To address the distortion problem, a multi-frame minimum variance distortionless response (MFMVDR) filtering technique is proposed.…
Unsupervised visual anomaly detection from multi-view images presents a significant challenge: distinguishing genuine defects from benign appearance variations caused by viewpoint changes. Existing methods, often designed for single-view…
We present a robust adaptive beamforming algorithm based on the worst-case criterion and the constrained constant modulus approach, which exploits the constant modulus property of the desired signal. Similarly to the existing worst-case…
Magnetic Resonance Imaging (MRI) is a kind of medical imaging technology used for diagnostic imaging of diseases, but its image quality may be suffered by the long acquisition time. The compressive sensing (CS) based strategy may decrease…
In this paper, a binaural beamforming algorithm for hearing aid applications is introduced.The beamforming algorithm is designed to be robust to some error in the estimate of the target speaker direction. The algorithm has two main…
Passive acoustic mapping (PAM) is a promising tool for monitoring acoustic cavitation activities in the applications of ultrasound therapy. Data-adaptive beamformers for PAM have better image quality compared to the time exposure acoustics…
To reconstruct the 3D geometry from calibrated images, learning-based multi-view stereo (MVS) methods typically perform multi-view depth estimation and then fuse depth maps into a mesh or point cloud. To improve the computational…
In multi-photon microscopy (MPM), a recent in-vivo fluorescence microscopy system, the task of image restoration can be decomposed into two interlinked inverse problems: firstly, the characterization of the Point Spread Function (PSF) and…
Medical Imaging (MI) tasks, such as accelerated parallel Magnetic Resonance Imaging (MRI), often involve reconstructing an image from noisy or incomplete measurements. This amounts to solving ill-posed inverse problems, where a satisfactory…