We report the first dark matter search results from XENON1T, a $\sim$2000-kg-target-mass dual-phase (liquid-gas) xenon time projection chamber in operation at the Laboratori Nazionali del Gran Sasso in Italy and the first ton-scale detector…

Cosmology and Nongalactic Astrophysics · Physics 2017-11-27 E. Aprile , J. Aalbers , F. Agostini , M. Alfonsi , F. D. Amaro , M. Anthony , F. Arneodo , P. Barrow , L. Baudis , B. Bauermeister , M. L. Benabderrahmane , T. Berger , P. A. Breur , A. Brown , A. Brown , E. Brown , S. Bruenner , G. Bruno , R. Budnik , L. Bütikofer , J. Calvén , J. M. R. Cardoso , M. Cervantes , D. Cichon , D. Coderre , A. P. Colijn , J. Conrad , J. P. Cussonneau , M. P. Decowski , P. de Perio , P. Di Gangi , A. Di Giovanni , S. Diglio , G. Eurin , J. Fei , A. D. Ferella , A. Fieguth , W. Fulgione , A. Gallo Rosso , M. Galloway , F. Gao , M. Garbini , R. Gardner , C. Geis , L. W. Goetzke , L. Grandi , Z. Greene , C. Grignon , C. Hasterok , E. Hogenbirk , J. Howlett , R. Itay , B. Kaminsky , S. Kazama , G. Kessler , A. Kish , H. Landsman , R. F. Lang , D. Lellouch , L. Levinson , Q. Lin , S. Lindemann , M. Lindner , F. Lombardi , J. A. M. Lopes , A. Manfredini , I. Mariş , T. Marrodán Undagoitia , J. Masbou , F. V. Massoli , D. Masson , D. Mayani , M. Messina , K. Micheneau , A. Molinario , K. Morå , M. Murra , J. Naganoma , K. Ni , U. Oberlack , P. Pakarha , B. Pelssers , R. Persiani , F. Piastra , J. Pienaar , V. Pizzella , M. -C. Piro , G. Plante , N. Priel , L. Rauch , S. Reichard , C. Reuter , B. Riedel , A. Rizzo , S. Rosendahl , N. Rupp , R. Saldanha , J. M. F. dos Santos , G. Sartorelli , M. Scheibelhut , S. Schindler , J. Schreiner , M. Schumann , L. Scotto Lavina , M. Selvi , P. Shagin , E. Shockley , M. Silva , H. Simgen , M. v. Sivers , A. Stein , S. Thapa , D. Thers , A. Tiseni , G. Trinchero , C. Tunnell , M. Vargas , N. Upole , H. Wang , Z. Wang , Y. Wei , C. Weinheimer , J. Wulf , J. Ye , Y. Zhang , T. Zhu

The DAMIC-M (DArk Matter In CCDs at Modane) experiment will use skipper CCDs to search for low mass (sub-GeV) dark matter underground at the Laboratoire Souterrain de Modane (LSM) in France. With about 1 kg of silicon target mass and…

High Energy Physics - Experiment · Physics 2024-10-01 R. Smida

The EDELWEISS experiment is a direct detection Dark Matter Search, under the form of WIMPs. It uses heat and ionization Ge cryogenic detectors. We present the latest results obtained by the experiment with three new 320g bolometers. At…

Astrophysics · Physics 2007-05-23 Veronique Sanglard

We propose a major upgrade to the existing PandaX-4T experiment in the China Jinping Underground Laboratory. The new experiment, PandaX-xT, will be a multi-ten-tonne liquid xenon, ultra-low background, and general-purpose observatory. The…

An energy threshold of (220$\pm$10) eV was achieved at an efficiency of 50% with a four-channel ultra-low-energy germanium detector each with an active mass of 5 g\cite{wimppaper}. This provides a unique probe to WIMP dark matter with mass…

Astrophysics · Physics 2019-08-13 Shin-Ted Lin , H. T. Wong

The XENON100 collaboration has recently released new dark matter limits, placing particular emphasis on their impact on searches known to be sensitive to light-mass (below 10 GeV/c^2) Weakly Interacting Massive Particles (WIMPs), such as…

Cosmology and Nongalactic Astrophysics · Physics 2010-05-14 J. I. Collar , D. N. McKinsey

One IGEX 76Ge double-beta decay detector is currently operating in the Canfranc Underground Laboratory in a search for dark matter WIMPs, through the Ge nuclear recoil produced by the WIMP elastic scattering. A new exclusion plot has been…

The Large Underground Xenon (LUX) collaboration has designed and constructed a dual-phase xenon detector, in order to conduct a search for Weakly Interacting Massive Particles(WIMPs), a leading dark matter candidate. The goal of the LUX…

The CDMS and EDELWEISS collaborations have combined the results of their direct searches for dark matter using cryogenic germanium detectors. The total data set represents 614 kg.d equivalent exposure. A straightforward method of…

Cosmology and Nongalactic Astrophysics · Physics 2015-03-19 CDMS , EDELWEISS Collaborations , : , Z. Ahmed , D. S. Akerib , E. Armengaud , S. Arrenberg , C. Augier , C. N. Bailey , D. Balakishiyeva , L. Baudis , D. A. Bauer , A. Benoît , L. Bergé , J. Blümer , P. L. Brink , A. Broniatowski , T. Bruch , V. Brudanin , R. Bunker , B. Cabrera , D. O. Caldwell , B. Censier , M. Chapellier , G. Chardin , F. Charlieux , J. Cooley , P. Coulter , G. A. Cox , P. Cushman , M. Daal , X. Defay , M. De Jesus , F. DeJongh , P. C. F. Di Stefano , Y. Dolgorouki , J. Domange , L. Dumoulin , M. R. Dragowsky , K. Eitel , S. Fallows , E. Figueroa-Feliciano , J. Filippini , D. Filosofov , N. Fourches , J. Fox , M. Fritts , J. Gascon , G. Gerbier , J. Gironnet , S. R. Golwala , M. Gros , J. Hall , R. Hennings-Yeomans , S. Henry , S. A. Hertel , S. Hervé , D. Holmgren , L. Hsu , M. E. Huber , A. Juillard , O. Kamaev , M. Kiveni , H. Kluck , M. Kos , V. Kozlov , H. Kraus , V. A. Kudryavtsev , S. W. Leman , S. Liu , P. Loaiza , R. Mahapatra , V. Mandic , S. Marnieros , C. Martinez , K. A. McCarthy , N. Mirabolfathi , D. Moore , P. Nadeau , X-F. Navick , H. Nelson , C. Nones , R. W. Ogburn , E. Olivieri , P. Pari , L. Pattavina , B. Paul , A. Phipps , M. Pyle , X. Qiu , W. Rau , A. Reisetter , Y. Ricci , M. Robinson , S. Rozov , T. Saab , B. Sadoulet , J. Sander , V. Sanglard , B. Schmidt , R. W. Schnee , S. Scorza , D. N. Seitz , S. Semikh , B. Serfass , K. M. Sundqvist , M. Tarka , A. S. Torrento-Coello , L. Vagneron , M. -A. Verdier , R. J. Walker , P. Wikus , E. Yakushev , S. Yellin , J. Yoo , B. A. Young , J. Zhang

The DAMIC (Dark Matter in CCDs) experiment uses high resistivity, scientific grade CCDs to search for dark matter. The CCD's low electronic noise allows an unprecedently low energy threshold of a few tens of eV that make it possible to…

The status and plans of a research program on the development of ultra-low-energy germanium detectors with sub-keV sensitivities are reported. We survey the scientific goals which include the observation of neutrino-nucleus coherent…

High Energy Physics - Experiment · Physics 2008-11-26 Henry T. Wong

The LUX-ZEPLIN dark matter search aims to achieve a sensitivity to the WIMP-nucleon spin-independent cross-section down to (1--2)$\times10^{-12}$\,pb at a WIMP mass of 40 GeV/$c^2$. This paper describes the simulations framework that, along…

Instrumentation and Detectors · Physics 2020-06-25 ZEPLIN Collaboration , D. S. Akerib , C. W. Akerlof , A. Alqahtani , S. K. Alsum , T. J. Anderson , N. Angelides , H. M. Araújo , J. E. Armstrong , M. Arthurs , X. Bai , J. Balajthy , S. Balashov , J. Bang , D. Bauer , A. Baxter , J. Bensinger , E. P. Bernard , A. Bernstein , A. Bhatti , A. Biekert , T. P. Biesiadzinski , H. J. Birch , K. E. Boast , B. Boxer , P. Brás , J. H. Buckley , V. V. Bugaev , S. Burdin , J. K. Busenitz , R. Cabrita , C. Carels , D. L. Carlsmith , M. C. Carmona-Benitez , M. Cascella , C. Chan , N. I. Chott , A. Cole , A. Cottle , J. E. Cutter , C. E. Dahl , L. de Viveiros , J. E. Y. Dobson , E. Druszkiewicz , T. K. Edberg , S. R. Eriksen , A. Fan , S. Fayer , S. Fiorucci , H. Flaecher , E. D. Fraser , T. Fruth , R. J. Gaitskell , J. Genovesi , C. Ghag , E. Gibson , M. G. D. Gilchriese , S. Gokhale , M. G. D. van der Grinten , C. R. Hall , A. Harrison , S. J. Haselschwardt , S. A. Hertel , J. Y-K. Hor , M. Horn , D. Q. Huang , C. M. Ignarra , O. Jahangir , W. Ji , J. Johnson , A. C. Kaboth , A. C. Kamaha , K. Kamdin , K. Kazkaz , D. Khaitan , A. Khazov , I. Khurana , C. D. Kocher , L. Korley , E. V. Korolkova , J. Kras , H. Kraus , S. Kravitz , L. Kreczko , B. Krikler , V. A. Kudryavtsev , E. A. Leason , J. Lee , D. S. Leonard , K. T. Lesko , C. Levy , J. Li , J. Liao , F. -T. Liao , J. Lin , A. Lindote , R. Linehan , W. H. Lippincott , R. Liu , X. Liu , C. Loniewski , M. I. Lopes , B. López Paredes , W. Lorenzon , S. Luitz , J. M. Lyle , P. A. Majewski , A. Manalaysay , L. Manenti , R. L. Mannino , N. Marangou , M. F. Marzioni , D. N. McKinsey , J. McLaughlin , Y. Meng , E. H. Miller , E. Mizrachi , A. Monte , M. E. Monzani , J. A. Morad , E. Morrison , B. J. Mount , A. St. J. Murphy , D. Naim , A. Naylor , C. Nedlik , C. Nehrkorn , H. N. Nelson , F. Neves , J. A. Nikoleyczik , A. Nilima , I. Olcina , K. C. Oliver-Mallory , S. Pal , K. J. Palladino , J. Palmer , N. Parveen , E. K. Pease , B. Penning , G. Pereira , A. Piepke , K. Pushkin , J. Reichenbacher , C. A. Rhyne , A. Richards , Q. Riffard , G. R. C. Rischbieter , R. Rosero , P. Rossiter , G. Rutherford , D. Santone , A. B. M. R. Sazzad , R. W. Schnee , M. Schubnell , P. R. Scovell , D. Seymour , S. Shaw , T. A. Shutt , J. J. Silk , C. Silva , R. Smith , M. Solmaz , V. N. Solovov , P. Sorensen , I. Stancu , A. Stevens , K. Stifter , T. J. Sumner , N. Swanson , M. Szydagis , M. Tan , W. C. Taylor , R. Taylor , D. J. Temples , P. A. Terman , D. R. Tiedt , M. Timalsina , A. Tomás , M. Tripathi , D. R. Tronstad , W. Turner , L. Tvrznikova , U. Utku , A. Vacheret , A. Vaitkus , J. J. Wang , W. Wang , J. R. Watson , R. C. Webb , R. G. White , T. J. Whitis , F. L. H. Wolfs , D. Woodward , X. Xiang , J. Xu , M. Yeh , P. Zarzhitsky

Possible hints for WIMP dark matter with mass around 10 GeV coming from the DAMA, CoGeNT, and maybe also CRESST experiments are presented, and confronted with constraints from CDMS and XENON data. Focusing on spin-independent (SI)…

High Energy Physics - Phenomenology · Physics 2010-11-29 Thomas Schwetz

The EDELWEISS collaboration has performed a direct search for WIMP dark matter using a 320 g heat-and-ionization cryogenic Ge detector operated in a low-background environment in the Laboratoire Souterrain de Modane. No nuclear recoils are…

We report results from a blind analysis of the final data taken with the Cryogenic Dark Matter Search experiment (CDMS II) at the Soudan Underground Laboratory, Minnesota, USA. A total raw exposure of 612 kg-days was analyzed for this work.…

Cosmology and Nongalactic Astrophysics · Physics 2014-11-20 The CDMS Collaboration , Z. Ahmed

The IGEX Collaboration enriched 76Ge double-beta decay detectors are currently operating in the Canfranc Underground Laboratory with an overburden of 2450 m.w.e. A recent upgrade has made it possible to use them in a search for WIMPs. A new…

Weakly Interacting Massive Particles (WIMPs), are a leading candidate for the dark matter that is observed to constitute ~25% of the total mass-energy density of the Universe. The direct detection of relic WIMPs (those produced during the…

Instrumentation and Detectors · Physics 2017-08-23 Tarek Saab

The EDELWEISS-II collaboration has performed a direct search for WIMP dark matter with an array of ten 400 g heat-and-ionization cryogenic detectors equipped with interleaved electrodes for the rejection of near-surface events. Six months…

The ZEPLIN-III experiment in the Palmer Underground Laboratory at Boulby uses a 12kg two-phase xenon time projection chamber to search for the weakly interacting massive particles (WIMPs) that may account for the dark matter of our Galaxy.…

The LUX collaboration new results advance the search for dark matter candidate particles in the 4 GeV/c^2 and higher mass range, with a maximal spin-independent 90% C.L. limit of 2 x 10^-46 cm^2 at 50 GeV/c^2 for its 332 live-day run,…

Cosmology and Nongalactic Astrophysics · Physics 2019-08-15 M. Szydagis