English
Related papers

Related papers: 200x Low-dose PET Reconstruction using Deep Learni…

200 papers

To obtain high-quality positron emission tomography (PET) while minimizing radiation exposure, a range of methods have been designed to reconstruct standard-dose PET (SPET) from corresponding low-dose PET (LPET) images. However, most…

Image and Video Processing · Electrical Eng. & Systems 2024-04-11 Yuchen Fei , Yanmei Luo , Yan Wang , Jiaqi Cui , Yuanyuan Xu , Jiliu Zhou , Dinggang Shen

Low-dose positron emission tomography (PET) image reconstruction methods have potential to significantly improve PET as an imaging modality. Deep learning provides a promising means of incorporating prior information into the image…

Computer Vision and Pattern Recognition · Computer Science 2024-09-11 Cameron Dennis Pain , Yasmeen George , Alex Fornito , Gary Egan , Zhaolin Chen

Positron emission tomography (PET) is a cornerstone of modern radiology. The ability to detect cancer and metastases in whole body scans fundamentally changed cancer diagnosis and treatment. One of the main bottlenecks in the clinical…

Computer Vision and Pattern Recognition · Computer Science 2022-04-28 Ida Häggström , C. Ross Schmidtlein , Gabriele Campanella , Thomas J. Fuchs

A standard dose of radioactive tracer must be delivered into the patients body to obtain high-quality Positron Emission Tomography (PET) images for diagnostic purposes, which raises the risk of radiation harm. A reduced tracer dose, on the…

Positron Emission Tomography (PET) image reconstruction is inherently challenged by Poisson noise and physical degradation factors, which are further exacerbated in limited-angle acquisitions. While deep learning methods demonstrate…

Computer Vision and Pattern Recognition · Computer Science 2026-05-11 Rüveyda Yilmaz , Yuli Wu , Johannes Stegmaier , Volkmar Schulz

Positron emission tomography (PET) is a critical tool for diagnosing tumors and neurological disorders but poses radiation risks to patients, particularly to sensitive populations. While reducing injected radiation dose mitigates this risk,…

Image and Video Processing · Electrical Eng. & Systems 2026-04-01 Yucun Hou , Fenglin Zhan , Xin Cheng , Chenxi Li , Ziquan Yuan , Runze Liao , Haihao Wang , Jianlang Hua , Jing Wu , Jianyong Jiang

Positron emission tomography (PET) is an important functional medical imaging technique often used in the evaluation of certain brain disorders, whose reconstruction problem is ill-posed. The vast majority of reconstruction methods in PET…

Image and Video Processing · Electrical Eng. & Systems 2023-06-09 Tin Vlašić , Tomislav Matulić , Damir Seršić

The application of ionizing radiation for diagnostic imaging is common around the globe. However, the process of imaging, itself, remains to be a relatively hazardous operation. Therefore, it is preferable to use as low a dose of ionizing…

Image and Video Processing · Electrical Eng. & Systems 2023-11-01 A. Demir , M. M. A. Shames , O. N. Gerek , S. Ergin , M. Fidan , M. Koc , M. B. Gulmezoglu , A. Barkana , C. Calisir

Radiation exposure in positron emission tomography (PET) imaging limits its usage in the studies of radiation-sensitive populations, e.g., pregnant women, children, and adults that require longitudinal imaging. Reducing the PET radiotracer…

Image and Video Processing · Electrical Eng. & Systems 2021-07-22 Viswanath P. Sudarshan , Uddeshya Upadhyay , Gary F. Egan , Zhaolin Chen , Suyash P. Awate

Low-Dose computer tomography (LDCT) is an ideal alternative to reduce radiation risk in clinical applications. Although supervised-deep-learning-based reconstruction methods have demonstrated superior performance compared to conventional…

Image and Video Processing · Electrical Eng. & Systems 2024-05-24 Feng Wang , Renfang Wang , Hong Qiu

In order to reduce the potential radiation risk, low-dose CT has attracted more and more attention. However, simply lowering the radiation dose will significantly degrade the imaging quality. In this paper, we propose a noise reduction…

Medical Physics · Physics 2016-09-28 Hu Chen , Yi Zhang , Weihua Zhang , Peixi Liao , Ke Li , Jiliu Zhou , Ge Wang

X-ray Computed Tomography (CT) is an important tool in medical imaging to obtain a direct visualization of patient anatomy. However, the x-ray radiation exposure leads to the concern of lifetime cancer risk. Low-dose CT scan can reduce the…

Medical Physics · Physics 2018-10-30 Guoyang Ma , Chenyang Shen , Xun Jia

Positron Emission Tomography (PET) is an essential technique in many clinical applications that allows for quantitative imaging at the molecular level. This study aims to develop a denoising method using novel dilated convolutional neural…

Medical Physics · Physics 2021-01-27 Karl Spuhler , Mario Serrano-Sosa , Renee Cattell , Christine DeLorenzo , Chuan Huang

Synchrotron-based X-ray computed tomography is widely used for investigating inner structures of specimens at high spatial resolutions. However, potential beam damage to samples often limits the X-ray exposure during tomography experiments.…

Image and Video Processing · Electrical Eng. & Systems 2020-09-30 Ziling Wu , Tekin Bicer , Zhengchun Liu , Vincent De Andrade , Yunhui Zhu , Ian T. Foster

Positron emission tomography (PET) is the most sensitive molecular imaging modality routinely applied in our modern healthcare. High radioactivity caused by the injected tracer dose is a major concern in PET imaging and limits its clinical…

Image and Video Processing · Electrical Eng. & Systems 2023-04-04 Yuxin Xue , Yige Peng , Lei Bi , Dagan Feng , Jinman Kim

18F-fluorodeoxyglucose (18F-FDG) Positron Emission Tomography (PET) imaging usually needs a full-dose radioactive tracer to obtain satisfactory diagnostic results, which raises concerns about the potential health risks of radiation…

Image and Video Processing · Electrical Eng. & Systems 2022-02-15 Yu Fu , Shunjie Dong , Yi Liao , Le Xue , Yuanfan Xu , Feng Li , Qianqian Yang , Tianbai Yu , Mei Tian , Cheng Zhuo

As a sensitive functional imaging technique, positron emission tomography (PET) plays a critical role in early disease diagnosis. However, obtaining a high-quality PET image requires injecting a sufficient dose (standard dose) of…

Image and Video Processing · Electrical Eng. & Systems 2024-12-06 Caiwen Jiang , Mianxin Liu , Kaicong Sun , Dinggang Shen

Positron Emission Tomography (PET) is a vital imaging modality widely used in clinical diagnosis and preclinical research but faces limitations in image resolution and signal-to-noise ratio due to inherent physical degradation factors.…

Image and Video Processing · Electrical Eng. & Systems 2024-11-11 Boxiao Yu , Kuang Gong

Direct reconstruction of positron emission tomography (PET) data using deep neural networks is a growing field of research. Initial results are promising, but often the networks are complex, memory utilization inefficient, produce…

Image and Video Processing · Electrical Eng. & Systems 2020-06-16 William Whiteley , Vladimir Panin , Chuanyu Zhou , Jorge Cabello , Deepak Bharkhada , Jens Gregor

Reducing scan times, radiation dose, and enhancing image quality for lower-performance scanners, are critical in low-dose PET imaging. Deep learning techniques have been investigated for PET image denoising. However, existing models have…

‹ Prev 1 2 3 10 Next ›