Related papers: Phase sensitivity of gain-unbalanced nonlinear int…
We study a nonlinear interferometer consisting of two consecutive parametric amplifiers, where all three optical fields (pump, signal and idler) are treated quantum mechanically, allowing for pump depletion and other quantum phenomena. The…
The sensitivity properties of an SU(1,1) interferometer made of two cascaded parametric amplifiers, as well as of an ordinary SU(2) interferometer preceded by a squeezer and followed by an anti-squeezer, are theoretically investigated.…
We provide general bounds of phase estimation sensitivity in linear two-mode interferometers. We consider probe states with a fluctuating total number of particles. With incoherent mixtures of state with different total number of particles,…
In an unseeded SU(1,1) interferometer composed of two cascaded degenerate parametric amplifiers, with direct detection at the output, we demonstrate a phase sensitivity overcoming the shot noise limit by 2.3 dB. The interferometer is…
Nonlinear interferometers are promising tools for quantum metrology, as they are characterized by an improved phase sensitivity scaling compared to linear interferometers operating with classical light. However, the multimodeness of the…
We investigate the scaling of the phase sensitivity of a nonideal Heisenberg-limited interferometer with the particle number N, in the case of the Bayesian detection procedure proposed by Holland and Burnett [p.r.l. 71, p. 1355 (1993)] for…
Over the past decade, several schemes for imaging and sensing based on nonlinear interferometers have been proposed and demonstrated experimentally. These interferometers exhibit two main advantages. First, they enable probing a sample at a…
Phase measurement using a lossless Mach-Zehnder interferometer with certain entangled $N$-photon states can lead to a phase sensitivity of the order of 1/N, the Heisenberg limit. However, previously considered output measurement schemes are…
The sensitivity in optical interferometry is strongly affected by losses during the signal propagation or at the detection stage. The optimal quantum states of the probing signals in the presence of loss were recently found. However, in…
In this paper we address the problem of optimizing an unbalanced Mach-Zehnder interferometer, for a given pure input state and considering a specific detection scheme. While the optimum transmission coefficient of the first beam splitter…
Quantum sensing using non-linear interferometers offers the possibility of bicolour imaging, using light that never interacted with the object of interest, and provides a way to achieve phase supersensitivity, i.e. a Heisenberg-type scaling…
Many works have stated that nonlinear interactions can improve phase sensitivity beyond the Heisenberg limit scaling of $1/N$ with $N$ being the mean photon number. This raises some open questions---among them the conclusive sensitivity…
We theoretically study the effects of loss on the phase sensitivity of an SU(1,1) interferometer with parity detection with various input states. We show that although the sensitivity of phase estimation decreases in the presence of loss,…
We derive the asymptotic maximum-likelihood phase estimation uncertainty for any interferometric protocol where the positions of the probe particles are measured to infer the phase, but where correlations between the particles are not…
Nonlinear interferometers with correlated photons hold a promise to advance optical characterization and metrology techniques by improving their performance and affordability. Nonlinear interferometers offer the sub-shot noise phase…
For a squeezing-enhanced SU(2) interferometer, we theoretically investigate the possibility to broaden the phase range of sub-shot-noise sensitivity. We show that this goal can be achieved by implementing detection in both output ports,…
Bose Einstein Condensates, with their coherence properties, have attracted wide interest for their possible application to ultra precise interferometry and ultra weak force sensors. Since condensates, unlike photons, are interacting, they…
SU(1,1) interferometers, based on the usage of nonlinear elements, are superior to passive interferometers in phase sensitivity. However, the SU(1,1) interferometer cannot make full use of photons carrying phase information as the second…
We report a theoretical and experimental study on the role of indistinguishability in the estimation of an interferometric phase. In particular, we show that the quantum Fisher information, which limits the maximum precision achievable in…
The best performance of a Mach-Zehnder interferometer is achieved with the input state |N_T/2 + 1>|N_T/2-1 > + |N_T/2 - 1>|N_T/2+1>, being N_T the total number of atoms/photons. This gives: i) a phase-shift error confidence C_{68%}=2.67/N_T…