English
Related papers

Related papers: Low background techniques in bolometers for double…

200 papers

Coherent neutrino-nucleon scattering offers a unique approach in the search for physics beyond the Standard Model. When used in conjunction with mono-energetic neutrino sources, the technique can be sensitive to the existence of light…

High Energy Physics - Phenomenology · Physics 2015-05-28 Joseph A. Formaggio , E. Figueroa-Feliciano , A. J. Anderson

This paper reports on the development of a technology involving $^{100}$Mo-enriched scintillating bolometers, compatible with the goals of CUPID, a proposed next-generation bolometric experiment to search for neutrinoless double-beta decay.…

A novel low temperature bolometric method has been devised and implemented for high-precision measurements of the microwave surface resistance of small single-crystal platelet samples having very low absorption, as a continuous function of…

Many experiments whose goal is the search for neutrino-less double beta decay are taking data or in a final construction stage. The need for a tool that allows for an objective comparison between the sensitivity of different experiments is…

Instrumentation and Detectors · Physics 2014-02-21 M. Biassoni , O. Cremonesi , P. Gorla

We report in this paper the proofs that the pulse shape analysis can be used in some bolometers to identify the nature of the interacting particle. Indeed, while detailed analyses of the signal time development in purely thermal detectors…

Nuclear Experiment · Physics 2015-05-20 C. Arnaboldi , C. Brofferio , O. Cremonesi , L. Gironi , M. Pavan , G. Pessina , S. Pirro , E. Previtali

We present a new detection scheme for rejecting backgrounds in neutrino less double beta decay experiments. It relies on the detection of Cherenkov light emitted by electrons in the MeV region. The momentum threshold is tuned to reach a…

Instrumentation and Detectors · Physics 2015-05-20 Ioannis Giomataris

We report the development of a CaMoO4 crystal low temperature detector for the AMoRE neutrinoless double beta decay (0{\nu}\b{eta}\b{eta}) search experiment. The prototype detector cell was composed of a 216 g CaMoO4 crystal and a metallic…

Solar axions could be converted into x-rays inside the strong magnetic field of an axion helioscope, triggering the detection of this elusive particle. Low background x-ray detectors are an essential component for the sensitivity of these…

Noble liquid detectors have become an attractive option for exploring physics beyond the standard model. Current experiments are using these detectors to search for dark matter interactions, neutrinoless double beta decay, and other…

Instrumentation and Detectors · Physics 2019-10-15 Philip L. R. Weigel , Erin V. Hansen , Michelle J. Dolinski

We report the performances of a 0.51 kg CdWO4 scintillating bolometer to be used for future Double Beta Decay Experiments. The simultaneous read-out of the heat and the scintillation light allows to discriminate between different…

Nuclear Experiment · Physics 2014-11-21 C. Arnaboldi , J. W. Beeman , O. Cremonesi , L. Gironi , M. Pavan , G. Pessina , S. Pirro , E. Previtali

Neutrinoless double beta ($0\nu\beta\beta$) decay is the most promising way to determine whether neutrinos are Majorana particles. There are many experiments based on different isotopes searching for $0\nu\beta\beta$ decay. Combining the…

High Energy Physics - Phenomenology · Physics 2024-04-18 Shao-Long Chen , Yu-Qi Xiao

Cryogenic calorimeters, also known as bolometers, are among the leading technologies for searching for rare events. The CUPID experiment is exploiting this technology to deploy a tonne-scale detector to search for neutrinoless double-beta…

Instrumentation and Detectors · Physics 2025-03-07 The CUPID Collaboration , K. Alfonso , A. Armatol , C. Augier , F. T. Avignone , O. Azzolini , A. S. Barabash , G. Bari , A. Barresi , D. Baudin , F. Bellini , G. Benato , L. Benussi , V. Berest , M. Beretta , M. Bettelli , M. Biassoni , J. Billard , F. Boffelli , V. Boldrini , E. D. Brandani , C. Brofferio , C. Bucci , M. Buchynska , J. Camilleri , A. Campani , J. Cao , C. Capelli , S. Capelli , V. Caracciolo , L. Cardani , P. Carniti , N. Casali , E. Celi , C. Chang , M. Chapellier , H. Chen , D. Chiesa , D. Cintas , M. Clemenza , I. Colantoni , S. Copello , O. Cremonesi , R. J. Creswick , A. D'Addabbo , I. Dafinei , F. A. Danevich , F. De Dominicis , M. De Jesus , P. de Marcillac , S. Dell'Oro , S. Di Domizio , S. Di Lorenzo , V. Dompè , A. Drobizhev , L. Dumoulin , G. Fantini , M. El Idrissi , M. Faverzani , E. Ferri , F. Ferri , F. Ferroni , E. Figueroa-Feliciano , J. Formaggio , A. Franceschi , S. Fu , B. K. Fujikawa , J. Gascon , S. Ghislandi , A. Giachero , M. Girola , L. Gironi , A. Giuliani , P. Gorla , C. Gotti , C. Grant , P. Gras , P. V. Guillaumon , T. D. Gutierrez , K. Han , E. V. Hansen , K. M. Heeger , D. L. Helis , H. Z. Huang , M. T. Hurst , L. Imbert , A. Juillard , G. Karapetrov , G. Keppel , H. Khalife , V. V. Kobychev , Yu. G. Kolomensky , R. Kowalski , H. Lattaud , M. Lefevre , M. Lisovenko , R. Liu , Y. Liu , P. Loaiza , L. Ma , F. Mancarella , N. Manenti , A. Mariani , L. Marini , S. Marnieros , M. Martinez , R. H. Maruyama , Ph. Mas , D. Mayer , G. Mazzitelli , E. Mazzola , Y. Mei , M. N. Moore , S. Morganti , T. Napolitano , M. Nastasi , J. Nikkel , C. Nones , E. B. Norman , V. Novosad , I. Nutini , T. O'Donnell , E. Olivieri , M. Olmi , B. T. Oregui , S. Pagan , M. Pageot , L. Pagnanini , D. Pasciuto , L. Pattavina , M. Pavan , Ò. Penek , H. Peng , G. Pessina , V. Pettinacci , C. Pira , S. Pirro , O. Pochon , D. V. Poda , T. Polakovic , O. G. Polischuk , E. G. Pottebaum , S. Pozzi , E. Previtali , A. Puiu , S. Puranam , S. Quitadamo , A. Rappoldi , G. L. Raselli , A. Ressa , R. Rizzoli , C. Rosenfeld , P. Rosier , M. Rossella , J. A. Scarpaci , B. Schmidt , R. Serino , A. Shaikina , K. Shang , V. Sharma , V. N. Shlegel , V. Singh , M. Sisti , P. Slocum , D. Speller , P. T. Surukuchi , L. Taffarello , S. Tomassini , C. Tomei , A. Torres , J. A. Torres , D. Tozzi , V. I. Tretyak , D. Trotta , M. Velazquez , K. J. Vetter , S. L. Wagaarachchi , G. Wang , L. Wang , R. Wang , B. Welliver , J. Wilson , K. Wilson , L. A. Winslow , F. Xie , M. Xue , J. Yang , V. Yefremenko , V. I. Umatov , M. M. Zarytskyy , T. Zhu , A. Zolotarova , S. Zucchelli

Small cryogenic detectors with efficient background rejection now best longer established and heavier direct dark matter searches. This paper reviews the experiments, results and prospects.

Astrophysics · Physics 2007-05-23 P. C. F. Di Stefano

An experiment to search for hypothetical particle dark matter using cryogenic thermal detector, or bolometer is ongoing. The bolometer consists of eight pieces of 21 g LiF absorbers and sensitive NTD germanium thermistors attached to them…

High Energy Physics - Experiment · Physics 2008-11-26 W. Ootani , M. Minowa , K. Miuchi , Y. Inoue , T. Watanabe , M. Yoshida , Y. Ito , Y. Ootuka

Searches of new physics beyond the Standard Model (SM) performed at low energy frontiers are complementary to experiments carried out at high energy colliders. Among the methods for testing the SM and beyond at low energies are the…

Instrumentation and Detectors · Physics 2018-10-08 D. Rozpedzik , K. Bodek , K. Lojek , M. Perkowski , L. De Keukeleere , L. Hayen , N. Severijns , A. Kozela

Particle tracks and differential energy loss measured in high pressure gaseous detectors can be exploited for event identification in neutrinoless double beta decay~($0\nu \beta \beta$) searches. We develop a new method based on Kalman…

Instrumentation and Detectors · Physics 2021-07-07 Tao Li , Shaobo Wang , Yu Chen , Ke Han , Heng Lin , Kaixiang Ni , Wei Wang , Yiliu Xu , Anni Zou

Large mass bolometers are used in particle physics experiments to search for rare processes. By operating at low temperature, they are able to detect particle energies from few keV up to several MeV, measuring the temperature rise produced…

Instrumentation and Detectors · Physics 2010-10-27 M. Vignati

We propose an innovative demodulation scheme for coherent detectors used in cosmic microwave background polarization experiments. Removal of non-white noise, e.g., narrow-band noise, in detectors is one of the key requirements for the…

Instrumentation and Methods for Astrophysics · Physics 2012-05-22 K. Ishidoshiro , Y. Chinone , M. Hasegawa , M. Hazumi , M. Nagai , O. Tajima

In nuclear, particle and astroparticle physics experiments, calorimeters are used to measure the properties of particles with kinetic energies that range from a fraction of 1 eV to 10^20 eV or more. These properties are not necessarily…

Instrumentation and Detectors · Physics 2018-10-17 Richard Wigmans