English
Related papers

Related papers: Three-dimensional image reconstruction in J-PET us…

200 papers

Synchrotron radiation observed in a quiescent TCV runaway discharge is studied using filtered camera images targeting three distinct wavelength intervals. Through the tomographic SART procedure the high momentum, high pitch angle part of…

Here we apply hyperspectral bright field imaging to collect computed tomographic images with excellent energy resolution (800 eV), applying it for the first time to map the distribution of stain in a fixed biological sample through its…

Whole-body PET imaging is often hindered by respiratory motion during acquisition, causing significant degradation in the quality of reconstructed activity images. An additional challenge in PET/CT imaging arises from the respiratory phase…

In this study, we exhibit a number elementary strategies that might be at disposal in diverse computational applications in the GEANT4 simulations with the purpose of hemispherical particle sources. To further detail, we initially generate…

Instrumentation and Methods for Astrophysics · Physics 2023-04-10 Ahmet Ilker Topuz , Madis Kiisk , Andrea Giammanco

Projective analysis is an important solution for 3D shape retrieval, since human visual perceptions of 3D shapes rely on various 2D observations from different view points. Although multiple informative and discriminative views are…

Computer Vision and Pattern Recognition · Computer Science 2017-04-03 Song Bai , Xiang Bai , Zhichao Zhou , Zhaoxiang Zhang , Longin Jan Latecki

A sparsity-exploiting algorithm intended for few-view Single Photon Emission Computed Tomography (SPECT) reconstruction is proposed and characterized. The algorithm models the object as piecewise constant subject to a blurring operation. To…

Medical Physics · Physics 2012-12-05 Paul A Wolf , Jakob H Jørgensen , Taly G Schmidt , Emil Y Sidky

To obtain high-quality Positron emission tomography (PET) images while minimizing radiation exposure, numerous methods have been proposed to reconstruct standard-dose PET (SPET) images from the corresponding low-dose PET (LPET) images.…

Image and Video Processing · Electrical Eng. & Systems 2024-04-10 Jiaqi Cui , Yan Wang , Lu Wen , Pinxian Zeng , Xi Wu , Jiliu Zhou , Dinggang Shen

Diffraction tomography (DT) has been widely explored in transmission-mode configurations, enabling high-resolution, label-free 3D imaging. However, industrial metrology applications, such as semiconductor inspection, typically involve…

Optics · Physics 2026-02-04 Jiabei Zhu , Tongyu Li , Hao Wang , Yi Shen , Guorong Hu , Lei Tian

We introduce a novel framework for upsampled Point Spread Function (PSF) modeling using pixel-level Bayesian inference. Accurate PSF characterization is critical for precision measurements in many fields including: weak lensing, astrometry,…

Instrumentation and Methods for Astrophysics · Physics 2025-11-26 Connor Stone , Ronan Legin , Alexandre Adam , Nikolay Malkin , Gabriel Missael Barco , Laurence Perreaul-Levasseur , Yashar Hezaveh

We present a Machine Learning-based method for tomographic reconstruction of dense layered objects, with range of projection angles limited to $\pm $10$^\circ$. Whereas previous approaches to phase tomography generally require two steps,…

Image and Video Processing · Electrical Eng. & Systems 2020-01-08 Alexandre Goy , Girish Rughoobur , Shuai Li , Kwabena Arthur , Akintunde I. Akinwande , George Barbastathis

The method of filtered back projection (FBP) is a widely used reconstruction technique in X-ray computerized tomography (CT), which is particularly important in clinical diagnostics. To reduce scanning times and radiation doses in medical…

Numerical Analysis · Mathematics 2024-08-14 Matthias Beckmann , Judith Nickel

We present the first on-sky results of the micro-lens ring tip-tilt (MLR-TT) sensor. This sensor utilizes a 3D printed micro-lens ring feeding six multi-mode fibers to sense misaligned light, allowing centroid reconstruction. A tip-tilt…

We consider the reconstruction of a two-dimensional discrete image from a set of tomographic measurements corresponding to the Radon projection. Assuming that the image has a structure where neighbouring pixels have a larger probability to…

Numerical Analysis · Computer Science 2013-04-04 Emmanuelle Gouillart , Florent Krzakala , Marc Mezard , Lenka Zdeborová

Positron emission tomography (PET) reconstruction is a critical challenge in molecular imaging, often hampered by noise amplification, structural blurring, and detail loss due to sparse sampling and the ill-posed nature of inverse problems.…

Computer Vision and Pattern Recognition · Computer Science 2026-02-13 Mengxiao Geng , Zijie Chen , Ran Hong , Bingxuan Li , Qiegen Liu

In parallel beam computed tomography (CT), an object is reconstructed from a series of projections taken at different angles. However, in some industrial and biomedical imaging applications, the projection geometry is unknown, completely or…

Image and Video Processing · Electrical Eng. & Systems 2025-12-23 Shreyas Jayant Grampurohit , Satish Mulleti , Ajit Rajwade

A method for photoacoustic tomography is presented that uses circular integrals of the acoustic wave for the reconstruction of a three-dimensional image. Image reconstruction is a two-step process: In the first step data from a stack of…

Numerical Analysis · Mathematics 2009-12-06 G. Zangerl , O. Scherzer , M. Haltmeier

Fast image reconstruction techniques are becoming important with the increasing number of scientific cases in high resolution micro and nano tomography. The processing of the large scale three-dimensional data demands new mathematical tools…

Numerical Analysis · Mathematics 2016-08-15 Nikolay Koshev , Elias S. Helou , Eduardo X. Miqueles

Received signal strength based radio tomographic imaging is a popular device-free indoor localization method which reconstructs the spatial loss field of the environment using measurements from a dense wireless network. Existing methods…

Emerging Technologies · Computer Science 2016-04-12 Hüseyin Yiğitler , Riku Jäntti , Ossi Kaltiokallio , Neal Patwari

Positron Emission Tomography (PET) scanners are usually designed with the goal to obtain the best compromise between sensitivity, resolution, field-of-view size, and cost. Therefore, it is difficult to improve the resolution of a PET…

Medical Physics · Physics 2023-07-18 Pablo Galve , Alejandro Lopez-Montes , Jose M Udias , Stephen C Moore , Joaquin L Herraiz