English
Related papers

Related papers: Three-dimensional image reconstruction in J-PET us…

200 papers

The Jagiellonian Positron Emission Tomograph (J-PET) is a detector for medical imaging of the whole human body as well as for physics studies involving detection of electron-positron annihilation into photons. J-PET has high angular and…

Single Photon Emission Computed Tomography (SPECT) is a non-invasive imaging modality, frequently used in myocardial perfusion imaging. The biggest challenges facing the majority of clinical SPECT systems are low sensitivity, poor…

Medical Physics · Physics 2021-03-30 Narayan Bhusal

A novel method performing 3D PTV from double frame multi-camera images is introduced. Particle velocities are estimated by following three steps. Firstly, separate particle reconstructions with a sparsity-based algorithm are performed on a…

In computed tomography, the reconstruction is typically obtained on a voxel grid. In this work, however, we propose a mesh-based reconstruction method. For tomographic problems, 3D meshes have mostly been studied to simulate data…

Image and Video Processing · Electrical Eng. & Systems 2021-03-12 Jakeoung Koo , Anders B. Dahl , J. Andreas Bærentzen , Qiongyang Chen , Sara Bals , Vedrana A. Dahl

Scientific imaging techniques such as optical and electron microscopy and computed tomography (CT) scanning are used to study the 3D structure of an object through 2D observations. These observations are related to the original 3D object…

Machine Learning · Computer Science 2019-06-21 Karen Ullrich , Rianne van den Berg , Marcus Brubaker , David Fleet , Max Welling

Time-resolved CT is an advanced measurement technique that has been widely used to observe dynamic objects, including periodically varying structures such as hearts, lungs, or hearing structures. To reconstruct these objects from CT…

Medical Physics · Physics 2025-06-05 Qianwei Qu , Christian M. Schlepütz , Marco Stampanoni

Diffusion models have shown great promise in medical image denoising and reconstruction, but their application to Positron Emission Tomography (PET) imaging remains limited by tracer-specific contrast variability and high computational…

Image and Video Processing · Electrical Eng. & Systems 2026-02-03 Fumio Hashimoto , Kuang Gong

In this work, we propose a method for three-dimensional (3D) reconstruction of wide crime scene, based on a Simultaneous Localization and Mapping (SLAM) approach. We used a Kinect V2 Time-of-Flight (TOF) RGB-D camera to provide colored…

Computer Vision and Pattern Recognition · Computer Science 2017-08-08 Silvio Giancola , Daniele Piron , Pasquale Poppa , Remo Sala

X-Ray based computed tomography (CT) is a well-established technique for determining the three-dimensional structure of an object from its two-dimensional projections. In the past few decades, there have been significant advancements in the…

Medical Physics · Physics 2023-04-26 Dinesh Kumar , Dilworth Y. Parkinson , Jeffrey J. Donatelli

A two-step shape reconstruction method for diffuse optical tomography (DOT) is presented which uses adjoint fields and level sets. The propagation of near-infrared photons in tissue is modeled by the time-dependent linear transport…

Numerical Analysis · Mathematics 2025-10-20 Oliver Dorn

Time of Flight Positron Emission Tomography scanner based on plastic scintillators is being developed at the Jagiellonian University by the J-PET collaboration. The main challenge of the conducted research lies in the elaboration of a…

Single Photon Emission Computed Tomography (SPECT) is one of the nuclear medicine imaging modalities used for functional analysis of animal and human organs. Gamma rays emitted from the scanned body are filtered with collimators and…

Image and Video Processing · Electrical Eng. & Systems 2020-12-15 Manu Francis , Muhammed Tarek , Mark Pickering , Murat Tahtali

The purpose of the presented investigations is to design, construct and establish the characteristic performance of the Jagiellonian Positron Emission Mammography(J-PEM), being designed for the detection and diagnosis of breast cancer. Its…

Medical Physics · Physics 2020-02-19 Shivani , Elżbieta Luczyńska , Sylwia Heinze , Paweł Moskal

We develop and evaluate MlPET, a fast localized machine learning approach for probabilistic PET image analysis addressing the noise-resolution trade-off in conventional reconstructions. MlPET replaces computationally demanding Markov chain…

Medical Physics · Physics 2026-01-27 Thomas Mejer Hansen , Nana Christensen , Mikkel Vendelbo

We present a sophisticated gamma-ray likelihood reconstruction technique for Imaging Atmospheric Cerenkov Telescopes. The technique is based on the comparison of the raw Cherenkov camera pixel images of a photon induced atmospheric particle…

Instrumentation and Methods for Astrophysics · Physics 2015-03-13 Mathieu de Naurois , Loic Rolland

Intraoperative Gamma Probe (IPG) remains the current gold standard modality for sentinel lymph node identification and tumor removal in cancer patients. However, even alongside the optical dyes they do not meet with <5% false negative rates…

Medical Physics · Physics 2022-01-26 S. Sajedi , L. Blackberg , S. Majewski , H. Sabet

Forward and backward scattering provide complementary volumetric and interfacial information, yet conventional three-dimensional (3D) imaging typically accesses only one. In this Letter, we present a substrate-enhanced diffraction…

Optics · Physics 2026-03-05 Tongyu Li , Yi Shen , Dashan Dong , Danchen Jia , Jianpeng Ao , Ji-Xin Cheng , Lei Tian

We introduce the learned simultaneous iterative reconstruction technique (SIRT) for tomographic reconstruction. The learned SIRT algorithm is a deep learning based reconstruction method combining model knowledge with a learned component.…

Image and Video Processing · Electrical Eng. & Systems 2019-08-29 Roeland J. Dilz , Lukas Schröder , Nikita Moriakov , Jan-Jakob Sonke , Jonas Teuwen

We present a direct method for limited angle tomographic reconstruction using convolutional networks. The key to our method is to first stretch every tilt view in the direction perpendicular to the tilt axis by the secant of the tilt angle.…

Image and Video Processing · Electrical Eng. & Systems 2023-06-21 Kyle Luther , Sebastian Seung

SPECT (Single-photon Emission Computerized Tomography) and PET (Positron Emission Tomography) are essential medical imaging tools, for which the sampling angle number, scan time should be chosen carefully to compromise between image quality…

Medical Physics · Physics 2015-06-16 Xiaolin Zhou , Minkai Yun , Xuexiang Cao , Shuangquan Liu , Lu Wang , Xianchao Huang , Long Wei
‹ Prev 1 4 5 6 7 8 10 Next ›