Related papers: Prototype high angular resolution LEKIDs for NIKA2
The Large Hadron Collider (LHC) at CERN will undergo an upgrade in order to increase its luminosity to $7.5 \times 10^{34}$ cm$^{-2}$s$^{-1}$. The increased luminosity during this High-Luminosity running phase (HL-LHC), starting around…
We present the first beam test results with centimeter-scale AC-LGAD strip sensors, using the Fermilab Test Beam Facility and sensors manufactured by the Brookhaven National Laboratory. Sensors of this type are envisioned for applications…
The future upgrade of Keck II telescope's adaptive optics system will include a pyramid wavefront sensor working in the near-infrared (J and H band). It will benefit from the recently developed avalanche photodiode arrays, specifically the…
We have developed a new on-axis digital holographic technique, heterodyne holography. The resolution of this technique is limited mainly by the amount of data recorded on two-dimensional photodetectors, i.e., the number of pixels and their…
Microwave Kinetic Inductance Detectors (MKIDs) are photon detectors comprised of superconducting LC resonators with unique resonant frequencies corresponding to their geometrical structure. As each pixel has its own geometry,…
We describe the in-flight performance of the horn-coupled Lumped Element Kinetic Inductance Detector arrays of the balloon-borne OLIMPO experiment. These arrays have been designed to match the spectral bands of OLIMPO: 150, 250, 350, and…
The LHC is expected to reach luminosities up to 3000fb-1 and the innermost layer of the ATLAS upgrade plans to cope with higher occupancy and to decrease the pixel size. 3D-Si sensors are a good candidate for the innermost layer of the…
The NIKA2 Guaranteed-Time SZ Large Program (LPSZ) is dedicated to the high-angular resolution SZ mapping of a representative sample of 45 SZ-selected galaxy clusters drawn from the catalogues of the Planck satellite, or of the Atacama…
For the high luminosity phase of the Large Hadron Collider to start operation around 2026, a major upgrade of the ATLAS Inner Tracker (ITk) is in preparation. Thanks to their low power dissipation and high charge-collection efficiency after…
In view of the LHC upgrade phases towards the High Luminosity LHC (HL-LHC), the ATLAS experiment plans to upgrade the Inner Detector with an all-silicon system. Because of its radiation hardness and cost effectiveness, the n-on-p silicon…
The planned HL-LHC (High Luminosity LHC) in 2025 is being designed to maximise the physics potential through a sizable increase in the luminosity up to 6*10^34 cm^-2 s^-1. A consequence of this increased luminosity is the expected radiation…
To cope with the higher occupancy and radiation damage at the HL-LHC also the LHC experiments will be upgraded. The ATLAS Planar Pixel Sensor R&D Project (PPS) is an international collaboration of 17 institutions and more than 80…
A way to fully exploit the large collecting area of modern 8-10m class telescopes is high resolution spectroscopy. Many astrophysical problems from planetary science to cosmology benefit from spectroscopic observations at the highest…
We present a new multi-pixel high resolution (R >10^7) spectrometer for the Stratospheric Observatory for Far-Infrared Astronomy (SOFIA). The receiver uses 2 x 7-pixel subarrays in orthogonal polarization, each in an hexagonal array around…
The upgrade for ATLAS detector will undergo different phase towards super-LHC. The first upgrade for the Pixel detector will consist of the construction of a new pixel layer which will be installed during the first shutdown of the LHC…
A state-of-the-art Resonant Inelastic X-ray Scattering (RIXS) facility, composed of a dedicated beamline and a 2D-RIXS spectrometer, has been constructed and commissioned at BL02U in NanoTerasu, Japan. This paper reports the optical design…
Widefield quantum diamond microscopy is a powerful technique for imaging magnetic fields with high sensitivity and spatial resolution. However, current methods to approach the ultimate spatial resolution ($<500\,$nm) are impractical for…
Recently, the multilevel diffractive lenses (MDLs) have attracted considerable attention mainly due to their superior wave focusing performance; however, efforts to correct the chromatic aberration are still in progress. Here, we…
Preliminary specifications for the Square Kilometre Array (SKA) call for 25% of the total collecting area of the dish array to be located at distances greater than 180 km from the core, with a maximum baseline of at least 3000 km. The array…
We report a broadband long-wave infrared Fourier transform spectrometer with sensitivity exceeding that of previously reported direct-detection implementations. The system combines dual-comb spectroscopy with electro-optic sampling,…