CUPID is a next-generation neutrinoless double-beta decay experiment that will require cryogenic light detectors to improve background suppression, via the simultaneous readout of heat and light channels from its scintillating crystals. In…

CUPID-0 is the first pilot experiment of CUPID, a next-generation project for the measurement of neutrinoless double beta decay (0$\nu$DBD) with scintillating bolometers. The detector, consisting of 24 enriched and 2 natural ZnSe crystals,…

We collected 19.4 days of data from four 750 g TeO2 bolometers, and in three of them we were able to set the energy threshold around 3 keV using a new analysis technique. We found a background rate ranging from 25 cpd/keV/kg at 3 keV to 2…

Instrumentation and Detectors · Physics 2013-02-04 F. Alessandria , R. Ardito , D. R. Artusa , F. T. Avignone , O. Azzolini , M. Balata , T. I. Banks , G. Bari , J. Beeman , F. Bellini , A. Bersani , M. Biassoni , T. Bloxham , C. Brofferio , C. Bucci , X. Z. Cai , L. Canonica , S. Capelli , L. Carbone , L. Cardani , M. Carrettoni , N. Casali , N. Chott , M. Clemenza , C. Cosmelli , O. Cremonesi , R. J. Creswick , I. Dafinei , A. Dally , V. Datskov , A. De Biasi , M. P. Decowski , M. M. Deninno , S. Di Domizio , M. L. di Vacri , L. Ejzak , R. Faccini , D. Q. Fang , H. A. Farach , E. Ferri , F. Ferroni , E. Fiorini , M. A. Franceschi , S. J. Freedman , G. Frossati , B. K. Fujikawa , A. Giachero , L. Gironi , A. Giuliani , J. J. Goett , P. Gorla , C. Gotti , E. Guardincerri , T. D. Gutierrez , E. E. Haller , K. Han , K. M. Heeger , H. Z. Huang , R. Kadel , K. Kazkaz , G. Keppel , L. Kogler , Yu. G. Kolomensky , D. Lenz , Y. L. Li , C. Ligi , X. Liu , Y. G. Ma , C. Maiano , M. Maino , M. Martinez , R. H. Maruyama , N. Moggi , S. Morganti , T. Napolitano , S. Newman , S. Nisi , C. Nones , E. B. Norman , A. Nucciotti , F. Orio , D. Orlandi , J. L. Ouellet , M. Pallavicini , V. Palmieri , L. Pattavina , M. Pavan , M. Pedretti , G. Pessina , S. Pirro , E. Previtali , V. Rampazzo , F. Rimondi , C. Rosenfeld , C. Rusconi , S. Sangiorgio , N. D. Scielzo , M. Sisti , A. R. Smith , F. Stivanello , L. Taffarello , M. Tenconi , W. D. Tian , C. Tomei , S. Trentalange , G. Ventura , M. Vignati , B. S. Wang , H. W. Wang , C. A. Whitten , y T. Wise , A. Woodcraft , L. Zanotti , C. Zarra , B. X. Zhu , S. Zucchelli

Cryogenic macro-calorimeters instrumented with NTD thermistors have been developed for several decades. The choice of the optimal bias current is crucial for a proper operation of these detectors, both in terms of energy resolution and…

Cryogenic calorimetric experiments to search for neutrinoless double-beta decay ($0\nu\beta\beta$) are highly competitive, scalable and versatile in isotope. The largest planned detector array, CUPID, is comprised of about 1500 individual…

CUPID-Mo is a demonstrator experiment for the next generation $0\nu\beta\beta$ experiment CUPID. It consisted of an array of 20 Lithium Molybdate (LMO) cryogenic calorimeters with 20 Ge LDs for a dual readout of heat and light. In this…

Nuclear Experiment · Physics 2023-05-17 Toby Dixon

A scintillating bolometer based on a large cubic Li$_{2}$$^{100}$MoO$_4$ crystal (45 mm side) and a Ge wafer (scintillation detector) has been operated in the CROSS cryogenic facility at the Canfranc underground laboratory in Spain. The…

Instrumentation and Detectors · Physics 2021-03-24 The CUPID Interest Group , A. Armatol , E. Armengaud , W. Armstrong , C. Augier , F. T. Avignone , O. Azzolini , I. C. Bandac , A. S. Barabash , G. Bari , A. Barresi , D. Baudin , F. Bellini , G. Benato , M. Beretta , L. Bergé , Ch. Bourgeois , M. Biassoni , J. Billard , V. Boldrini , A. Branca , C. Brofferio , C. Bucci , J. M. Calvo-Mozota , J. Camilleri , A. Candela , S. Capelli , L. Cappelli , L. Cardani , P. Carniti , N. Casali , A. Cazes , E. Celi , C. Chang , M. Chapellier , A. Charrier , D. Chiesa , M. Clemenza , I. Colantoni , F. Collamati , S. Copello , F. Cova , O. Cremonesi , R. J. Creswick , A. Cruciani , A. D'Addabbo , G. D'Imperio , I. Dafinei , F. A. Danevich , M. de Combarieu , M. De Deo , M. De Jesus , P. de Marcillac , S. Dell'Oro , S. Di Domizio , V. Dompe , A. Drobizhev , L. Dumoulin , G. Fantini , M. Fasoli , M. Faverzani , E. Ferri , F. Ferri , F. Ferroni , E. Figueroa-Feliciano , J. Formaggio , A. Franceschi , C. Fu , S. Fu , B. K. Fujikawa , J. Gascon , A. Giachero , L. Gironi , A. Giuliani , P. Gorla , C. Gotti , P. Gras , M. Gros , E. Guerard , T. D. Gutierrez , K. Han , E. V. Hansen , K. M. Heeger , D. L. Helis , H. Z. Huang , R. G. Huang , A. Ianni , L. Imbert , J. Johnston , A. Juillard , G. Karapetrov , G. Keppel , H. Khalife , V. V. Kobychev , Yu. G. Kolomensky , S. I. Konovalov , Y. Liu , P. Loaiza , L. Ma , M. Madhukuttan , F. Mancarella , R. Mariam , L. Marini , S. Marnieros , M. Martinez , R. H. Maruyama , B. Mauri , D. Mayer , Y. Mei , S. Milana , D. Misiak , T. Napolitano , M. Nastasi , X. -F. Navick , J. Nikkel , R. Nipoti , S. Nisi , C. Nones , E. B. Norman , V. Novosad , I. Nutini , T. O'Donnell , G. Olivier , E. Olivieri , C. Oriol , J. L. Ouellet , S. Pagan , C. Pagliarone , L. Pagnanini , P. Pari , L. Pattavina , B. Paul , M. Pavan , H. Peng , G. Pessina , V. Pettinacci , C. Pira , S. Pirro , D. V. Poda , T. Polakovic , O. G. Polischuk , S. Pozzi , E. Previtali , A. Puiu , A. Ressa , D. Reynet , R. Rizzoli , C. Rosenfeld , V. Sanglard , J. A. Scarpaci , B. Schmidt , V. Sharma , V. N. Shlegel , V. Singh , M. Sisti , D. Speller , P. T. Surukuchi , L. Taffarello , O. Tellier , C. Tomei , V. I. Tretyak , A. Tsymbaliuk , A. Vedda , M. Velazquez , K. J. Vetter , S. L. Wagaarachchi , G. Wang , L. Wang , B. Welliver , J. Wilson , K. Wilson , L. A. Winslow , M. Xue , L. Yan , J. Yang , V. Yefremenko , V. I. Yumatov , M. M. Zarytskyy , J. Zhang , A. S. Zolotarova , S. Zucchelli

The suppression of spurious events in the region of interest for neutrinoless double beta decay will play a major role in next generation experiments. The background of detectors based on the technology of cryogenic calorimeters is expected…

A convincing observation of neutrino-less double beta decay (0$\nu$DBD) relies on the possibility of operating high energy-resolution detectors in background-free conditions. Scintillating cryogenic calorimeters are one of the most…

We report the in-situ 3D reconstruction of through-going muons in the CUORE experiment, a cryogenic calorimeter array searching for neutrinoless double beta ($0\nu\beta\beta$) decay, leveraging the segmentation of the detector. Due to the…

Instrumentation and Detectors · Physics 2025-09-09 CUORE Collaboration , D. Q. Adams , C. Alduino , K. Alfonso , A. Armatol , F. T. Avignone , O. Azzolini , G. Bari , F. Bellini , G. Benato , M. Beretta , M. Biassoni , A. Branca , D. Brandani , C. Brofferio , C. Bucci , J. Camilleri , A. Caminata , A. Campani , J. Cao , S. Capelli , L. Cappelli , L. Cardani , P. Carniti , N. Casali , D. Chiesa , Y. Chu , M. Clemenza , S. Copello , O. Cremonesi , R. J. Creswick , A. D'Addabbo , I. Dafinei , S. Dell'Oro , S. Di Domizio , S. Di Lorenzo , T. Dixon , D. Q. Fang , M. Faverzani , E. Ferri , F. Ferroni , E. Fiorini , M. A. Franceschi , S. J. Freedman , S. H. Fu , B. K. Fujikawa , S. Ghislandi , A. Giachero , M. Girola , L. Gironi , A. Giuliani , P. Gorla , C. Gotti , P. V. Guillaumon , T. D. Gutierrez , K. Han , E. V. Hansen , K. M. Heeger , D. L. Helis , H. Z. Huang , M. T. Hurst , G. Keppel , Yu. G. Kolomensky , R. Kowalski , R. Liu , L. Ma , Y. G. Ma , L. Marini , R. H. Maruyama , D. Mayer , M. N. Moore , T. Napolitano , M. Nastasi , C. Nones , E. B. Norman , A. Nucciotti , I. Nutini , T. O'Donnell , M. Olmi , S. Pagan , C. E. Pagliarone , L. Pagnanini , M. Pallavicini , L. Pattavina , M. Pavan , G. Pessina , V. Pettinacci , C. Pira , S. Pirro , E. G. Pottebaum , S. Pozzi , E. Previtali , A. Puiu , S. Puranam , S. Quitadamo , A. Ressa , C. Rosenfeld , B. Schmidt , R. Serino , A. Shaikina , V. Sharma , V. Singh , M. Sisti , D. Speller , P. T. Surukuchi , L. Taffarello , C. Tomei , A. Torres , J. A. Torres , K. J. Vetter , M. Vignati , S. L. Wagaarachchi , R. Wang , B. Welliver , J. Wilson , K. Wilson , L. A. Winslow , F. Xie , T. Zhu , S. Zimmermann , S. Zucchelli

Vibrations from experimental setups and the environment are a persistent source of noise for low-temperature calorimeters searching for rare events, including neutrinoless double beta ($0\nu\beta\beta$) decay or dark matter interactions.…

Instrumentation and Detectors · Physics 2026-05-07 D. Q. Adams , C. Alduino , K. Alfonso , A. Armatol , F. T. Avignone , O. Azzolini , G. Bari , F. Bellini , G. Benato , M. Beretta , M. Biassoni , A. Branca , C. Brofferio , C. Bucci , J. Camilleri , A. Caminata , A. Campani , J. Cao , C. Capelli , S. Capelli , L. Cappelli , L. Cardani , P. Carniti , N. Casali , E. Celi , D. Chiesa , M. Clemenza , S. Copello , A. Cosoli , O. Cremonesi , R. J. Creswick , A. D'Addabbo , I. Dafinei , S. Dell'Oro , S. Di Domizio , S. Di Lorenzo , D. Q. Fang , M. Faverzani , E. Ferri , F. Ferroni , E. Fiorini , M. A. Franceschi , S. J. Freedman , S. H. Fu , B. K. Fujikawa , S. Ghislandi , A. Giachero , M. Girola , L. Gironi , A. Giuliani , P. Gorla , C. Gotti , P. V. Guillaumon , T. D. Gutierrez , K. Han , E. V. Hansen , K. M. Heeger , D. L. Helis , H. Z. Huang , M. T. Hurst , G. Keppel , Yu. G. Kolomensky , R. Kowalski , R. Liu , L. Ma , Y. G. Ma , L. Marini , R. H. Maruyama , D. Mayer , Y. Mei , M. N. Moore , T. Napolitano , M. Nastasi , C. Nones , E. B. Norman , A. Nucciotti , I. Nutini , T. O'Donnell , M. Olmi , B. T. Oregui , S. Pagan , C. E. Pagliarone , L. Pagnanini , M. Pallavicini , L. Pattavina , M. Pavan , G. Pessina , V. Pettinacci , C. Pira , S. Pirro , E. G. Pottebaum , S. Pozzi , E. Previtali , A. Puiu , S. Quitadamo , A. Ressa , C. Rosenfeld , B. Schmidt , R. Serino , A. Shaikina , V. Sharma , V. Singh , M. Sisti , D. Speller , P. T. Surukuchi , L. Taffarello , C. Tomei , A. Torres , J. A. Torres , K. J. Vetter , M. Vignati , S. L. Wagaarachchi , B. Welliver , J. Wilson , K. Wilson , L. A. Winslow , F. Xie , T. Zhu , S. Zimmermann , S. Zucchelli , L. Aragão , A. Armigliato , R. Brancaccio , F. del Corso , S. Castellaro , G. De Luca , S. di Sabatino , P. Ruggieri , M. Zavatarelli

The external shell of the CUORE cryostat is a large cryogen-free system designed to host the dilution refrigerator and the bolometers of the CUORE experiment in a low radioactivity environment. The three vessels that form the outer shell…

The 19 towers constituting the CUORE detector are an assembly of ultra-radio-pure components made of copper and PTFE plus tellurium dioxide crystals for a total of more than 10,000 pieces. A dedicated assembly line is mandatory to handle…

Instrumentation and Detectors · Physics 2014-07-03 A. Buccheri , M. Capodiferro , S. Morganti , F. Orio , A. Pelosi , V. Pettinacci

CUPID will be a next generation experiment searching for the neutrinoless double $\beta$ decay, whose discovery would establish the Majorana nature of the neutrino. Based on the experience achieved with the CUORE experiment, presently…

Instrumentation and Detectors · Physics 2022-02-15 CUPID collaboration , A. Armatol , C. Augier , F. T. Avignone , O. Azzolini , M. Balata , K. Ballen , A. S. Barabash , G. Bari , A. Barresi , D. Baudin , F. Bellini , G. Benato , M. Beretta , M. Bettelli , M. Biassoni , J. Billard , V. Boldrini , A. Branca , C. Brofferio , C. Bucci , J. Camilleri , C. Capelli , S. Capelli , L. Cappelli , L. Cardani , P. Carniti , N. Casali , E. Celi , C. Chang , D. Chiesa , M. Clemenza , I. Colantoni , S. Copello , E. Craft , O. Cremonesi , R. J. Creswick , A. Cruciani , A. D'Addabbo , G. D'Imperio , S. Dabagov , I. Dafinei , F. A. Danevich , M. De Jesus , P. de Marcillac , S. Dell'Oro , S. Di Domizio , S. Di Lorenzo , T. Dixon , V. Dompè , A. Drobizhev , L. Dumoulin , G. Fantini , M. Faverzani , E. Ferri , F. Ferri , F. Ferroni , E. Figueroa-Feliciano , L. Foggetta , J. Formaggio , A. Franceschi , C. Fu , S. Fu , B. K. Fujikawa , A. Gallas , J. Gascon , S. Ghislandi , A. Giachero , A. Gianvecchio , L. Gironi , A. Giuliani , P. Gorla , C. Gotti , C. Grant , P. Gras , P. V. Guillaumon , T. D. Gutierrez , K. Han , E. V. Hansen , K. M. Heeger , D. L. Helis , H. Z. Huang , R. G. Huang , L. Imbert , J. Johnston , A. Juillard , G. Karapetrov , G. Keppel , H. Khalife , V. V. Kobychev , Yu. G. Kolomensky , S. I. Konovalov , R. Kowalski , T. Langford , M . Lefevre , R. Liu , Y. Liu , P. Loaiza , L. Ma , M. Madhukuttan , F. Mancarella , L. Marini , S. Marnieros , M. Martinez , R. H. Maruyama , Ph. Mas , B. Mauri , D. Mayer , G. Mazzitelli , Y. Mei , S. Milana , S. Morganti , T. Napolitano , M. Nastasi , J. Nikkel , S. Nisi , C. Nones , E. B. Norman , V. Novosad , I. Nutini , T. O'Donnell , E. Olivieri , M. Olmi , J. L. Ouellet , S. Pagan , C. Pagliarone , L. Pagnanini , L. Pattavina , M. Pavan , H. Peng , G. Pessina , V. Pettinacci , C. Pira , S. Pirro , D. V. Poda , O. G. Polischuk , I. Ponce , S. Pozzi , E. Previtali , A. Puiu , S. Quitadamo , A. Ressa , R. Rizzoli , C. Rosenfeld , P. Rosier , J. Scarpaci , B. Schmidt , V. Sharma , V. Shlegel , V. Singh , M. Sisti , P. Slocum , D. Speller , P. T. Surukuchi , L. Taffarello , C. Tomei , J. Torres , V. I. Tretyak , A. Tsymbaliuk , M. Velazquez , K. J. Vetter , S. L. Wagaarachchi , G. Wang , L. Wang , R. Wang , B. Welliver , J. Wilson , K. Wilson , L. A. Winslow , M. Xue , L. Yan , J. Yang , V. Yefremenko , V. I. Umatov , M. M. Zarytskyy , J. Zhang , A. Zolotarova , S. Zucchelli

The CUPID-0 detector hosted at the Laboratori Nazionali del Gran Sasso, Italy, is the first large array of enriched scintillating cryogenic detectors for the investigation of $^{82}$Se neutrinoless double-beta decay (0$\nu\beta\beta$).…

The present dissertation describes design, qualification and operation of several electronic instrumentations for High Energy Particle Physics experiments (LHCb) and Neutrino Physics experiments (CUORE and CUPID). Starting from 2019, the…

Instrumentation and Detectors · Physics 2018-08-31 Paolo Carniti

Chandra Surface Thermophysical Experiment (ChaSTE) is one of the payloads flown onboard the Chandrayaan-3 lander. The objective of the experiment is in-situ investigation of thermal behaviour of outermost 100 mm layer of the lunar surface…

This article presents the readout electronics of a novel beam monitoring system for ion research facility accelerator. The readout electronics are divided into Front-end Card (FEC) and Readout Control Unit (RCU). FEC uses Topmetal II minus…

Instrumentation and Detectors · Physics 2020-02-18 Honglin Zhang , Haibo Yang , Xianqin Li , Yuezhao Zhang , Xiangming Sun , Dong Wang , Ran Huang , Yao Wang , Wei Zhou , Chengxin Zhao

CUPID-0 is the first pilot experiment of CUPID, a next-generation project searching for neutrino-less double beta decay. In its first scientific run, CUPID-0 operated 26 ZnSe cryogenic calorimeters coupled to light detectors in the…

CUPID-Mo is a bolometric experiment to search for neutrinoless double-beta decay ($0\nu\beta\beta$) of $^{100}$Mo. In this article, we detail the CUPID-Mo detector concept, assembly, installation in the underground laboratory in Modane in…