English
Related papers

Related papers: Towards generalized data reduction on a chopper-ba…

200 papers

The exact resolution function in transfer vector for the reflectometer HERM\`ES at Laboratoire L\'eon Brillouin is calculated as an example of neutron time-of-fligh spectrometer with double-disk chopper. Calculation accounts for wavelength…

Instrumentation and Detectors · Physics 2020-03-30 Didier Lairez , Alexis Chennevière , Frédéric Ott

A time-of-flight device was developed to characterize wavelength distribution and uniformity of a cold neutron beam. This device is very compact -- the distance of flight is $60$ cm -- but achieves very high resolution -- the intrinsic…

A general virtual neutron experiment for TOF neutron reflectometer was introduced, including instrument simulation, sample modeling, detector simulation and data reduction to mimic the routine of real experimental process and data…

Instrumentation and Detectors · Physics 2017-01-18 Taisen Zuo , Haolai Tian , Yanyan Wang , Rong Du , Ming Tang , Junrong Zhang , Fang-Wei Wang , Yuan-Bo Chen

Progress in neutron decay experiments requires better methods for the characterization of electron detectors. I show that for such \b{eta}-decay studies, electron time-of-flight can be used for in-situ calibration of electron detectors.…

Instrumentation and Detectors · Physics 2016-11-02 Dirk Dubbers

Small-angle neutron scattering (SANS) is an experimental technique to detect material structures in the nanometer to micrometer range. The solution of the structural model constructed from SANS strongly depends on the accuracy of the…

Instrumentation and Detectors · Physics 2017-01-17 Rong Du , HaoLai Tian , TaiSen Zuo , Ming Tang , LiLi Yan , JunRong Zhang

Neutron correlation spectroscopy can exceed direct spectroscopy in the incoming beam intensity by up to two orders of magnitude at the same energy resolution. However, the propagation of the counting noise in the correlation algorithm of…

Instrumentation and Detectors · Physics 2016-09-13 F. Mezei , M. T. Caccamo , F. Migliardo , S. Magazù

Considering the OPERA neutrino-velocity measurement from the point of view of a GPS satellite we find that the detector at Gran Sasso has a velocity component in the order of $10^{-5}c$ towards the neutrino emission location at CERN. On…

General Physics · Physics 2011-11-22 Ronald A. J. van Elburg

Results of experimental investigations of a neutron resonances width in planar waveguides using the time-of-flight reflectometer REMUR of the IBR-2 pulsed reactor are reported and comparison with theoretical calculations is presented. The…

Instrumentation and Detectors · Physics 2017-03-08 S. V. Kozhevnikov , V. K. Ignatovich , A. V. Petrenko , F. Radu

We present proof-of-principle experiments of stroboscopic time-of-flight (TOF) neutron diffraction in long pulsed magnetic fields. By utilizing electric double-layer capacitors, we developed a long pulsed magnet for neutron diffraction…

Time-of-flight (ToF) measurements is a possible alternative to anti-scatter grids in computed tomography (CT). Simulations have shown a possible 75% reduction in the detrimental scattering contribution with a 100 ps FWHM timing resolution.…

We present a concept for an indirect geometry crystal time-of-flight spectrometer, which we propose for a source similar to the FRM-II reactor in Garching. Recently, crystal analyzer spectrometers at modern spallation sources have been…

Instrumentation and Detectors · Physics 2024-11-13 Ran Tang , Christop Herb , Jörg Voigt , Robert Georgii

Recent detector concepts at future linear or circular $e^- e^+$ colliders emphasize the benefits of time-of-flight measurements for particle identification of long-lived charged hadrons. That method relies on a precise estimation of the…

Instrumentation and Detectors · Physics 2021-09-16 Winfried A. Mitaroff

The response of the liquid scintillator array Nordball to neutrons in the energy range 1.5 < T_n < 10 MeV has been measured by time of flight using a 252Cf fission source. Fission fragments were detected by means of a thin-film plastic…

Instrumentation and Detectors · Physics 2009-11-11 A. Reiter

Accurate conversion of neutron time-of-flight (TOF) to wavelength, and its uncertainty, is of fundamental importance to neutron scattering measurements. Especially in cases where instruments are highly configurable, the determination of the…

Instrumentation and Detectors · Physics 2023-04-26 L. Vergara , M. Arai , R. Woracek , M. Olsson , A. Quintanilla , S. Alcock , J. Nilsson , K. Kanaki , P. M. Kadletz , O. Kirstein , R. Hall-Wilton , N. Tsapatsaris

We examine in analytic and numeric ways the imaging effects of temporal neutron lenses created by traveling magnetic fields. For fields of parabolic shape we derive the imaging equations, investigate the time-magnification, the evolution of…

Other Condensed Matter · Physics 2009-11-11 K. Baumann , R. Gaehler , P. D. Grigoriev , E. I. Kats

We have analyzed and compared the performance of two novel fast-neutron imaging methods with time-of-flight spectroscopy capability. Using MCNP and GEANT code simulations of neutron and charged-particle transport in the detectors, key…

Instrumentation and Detectors · Physics 2009-11-10 D. Vartsky , I. Mor , M. B. Goldberg , I. Mardor , G. Feldman , D. Bar , A. Shor , V. Dangendorf , G. Laczko , A. Breskin , R. Chechik

We have developed an innovative methodology for obtaining the neutron energy distribution from a time-of-flight (TOF) measurement based on the iterative Bayesian unfolding method and accurate Monte Carlo simulations. This methodology has…

Data Analysis, Statistics and Probability · Physics 2024-09-26 A. Pérez de Rada Fiol , D. Cano-Ott , T. Martínez , V. Alcayne , E. Mendoza , J. Plaza , A. Sanchez-Caballero , D. Villamarín

To achieve the sensitivity required to detect signals from neutral hydrogen from the Cosmic Dawn and Epoch of Reionisation it is critical to have a well-calibrated instrument which has a stable calibration over the course of the…

Instrumentation and Methods for Astrophysics · Physics 2026-03-04 Christian J. Kirkham , Dominic J. Anstey , Eloy de Lera Acedo

A time-of-flight spectrometer of neutrons in the energy range (0.05 -- 2.5)$\mu$eV is described. This spectrometer has been tested my measuring the total and differential neutron cross sections for a number of materials: Al, Cu, $^{6}$LiF,…

Nuclear Experiment · Physics 2011-02-15 Yu. N. Pokotilovski , M. I. Novopoltsev , P. Geltenbort , Th. Brenner

We developed an optical device for ultra-cold neutrons and investigated the influence of a tilt of its guiding components. A measurement of the time-of-flight of the neutrons through the device by means of a dedicated chopper system was…

Instrumentation and Detectors · Physics 2014-11-20 C. Plonka-Spehr , A. Kraft , P. Iaydjiev , J. Klepp , V. Nesvizhevsky , P. Geltenbort , Th. Lauer
‹ Prev 1 2 3 10 Next ›