English
Related papers

Related papers: Position Reconstruction in LUX

200 papers

The response of a position-sensitive Li-glass based scintillation detector to focused beams of 2.5 MeV protons and deuterons has been investigated. The beams were scanned across the detector in 0.5 mm horizontal and vertical steps…

DEAP-3600 is a single-phase liquid argon dark matter detector being operated 2 km underground at SNOLAB, Sudbury, Canada. The detector consists of 3.3 tonnes of ultra-pure liquid argon in a spherical acrylic cryostat instrumented with 255…

Instrumentation and Detectors · Physics 2020-06-17 Yu Chen

Currently inorganic scintillator detectors are used in all commercial Time of Flight Positron Emission Tomograph (TOF-PET) devices. The J-PET collaboration investigates a possibility of construction of a PET scanner from plastic…

We present a sophisticated gamma-ray likelihood reconstruction technique for Imaging Atmospheric Cerenkov Telescopes. The technique is based on the comparison of the raw Cherenkov camera pixel images of a photon induced atmospheric particle…

Instrumentation and Methods for Astrophysics · Physics 2015-03-13 Mathieu de Naurois , Loic Rolland

The MicroBooNE detector is a liquid argon time projection chamber at Fermilab designed to study short-baseline neutrino oscillations and neutrino-argon interaction cross-section. Due to its location near the surface, a good understanding of…

High Energy Physics - Experiment · Physics 2023-02-17 MicroBooNE collaboration , R. Acciarri , C. Adams , R. An , J. Anthony , J. Asaadi , M. Auger , L. Bagby , S. Balasubramanian , B. Baller , C. Barnes , G. Barr , M. Bass , F. Bay , M. Bishai , A. Blake , T. Bolton , L. Camilleri , D. Caratelli , B. Carls , R. Castillo Fernandez , F. Cavanna , H. Chen , E. Church , D. Cianci , E. Cohen , G. H. Collin , J. M. Conrad , M. Convery , J. I. Crespo-Anadon , M. Del Tutto , D. Devitt , S. Dytman , B. Eberly , A. Ereditato , L. Escudero Sanchez , J. Esquivel , A. A. Fadeeva , B. T. Fleming , W. Foreman , A. P. Furmanski , D. Garcia-Gamez , G. T. Garvey , V. Genty , D. Goeldi , S. Gollapinni , N. Graf , E. Gramellini , H. Greenlee , R. Grosso , R. Guenette , A. Hackenburg , P. Hamilton , O. Hen , V Hewes , C. Hill , J. Ho , G. Horton-Smith , A. Hourlier , E. -C. Huang , C. James , J. Jan de Vries , C. -M. Jen , L. Jiang , R. A. Johnson , J. Joshi , H. Jostlein , D. Kaleko , L. N. Kalousis , G. Karagiorgi , W. Ketchum , B. Kirby , M. Kirby , T. Kobilarcik , I. Kreslo , G. Lange , A. Laube , Y. Li , A. Lister , B. R. Littlejohn , S. Lockwitz , D. Lorca , W. C. Louis , M. Luethi , B. Lundberg , X. Luo , A. Marchionni , C. Mariani , J. Marshall , D. A. Martinez Caicedo , V. Meddage , T. Miceli , G. B. Mills , J. Moon , M. Mooney , C. D. Moore , J. Mousseau , R. Murrells , D. Naples , P. Nienaber , J. Nowak , O. Palamara , V. Paolone , V. Papavassiliou , S. F. Pate , Z. Pavlovic , R. Pelkey , E. Piasetzky , D. Porzio , G. Pulliam , X. Qian , J. L. Raaf , A. Rafique , L. Rochester , C. Rudolf von Rohr , B. Russell , D. W. Schmitz , A. Schukraft , W. Seligman , M. H. Shaevitz , J. Sinclair , A. Smith , E. L. Snider , M. Soderberg , S. Soldner-Rembold , S. R. Soleti , P. Spentzouris , J. Spitz , J. St. John , T. Strauss , A. M. Szelc , N. Tagg , K. Terao , M. Thomson , M. Toups , Y. -T. Tsai , S. Tufanli , T. Usher , W. Van De Pontseele , R. G. Van de Water , B. Viren , M. Weber , D. A. Wickremasinghe , S. Wolbers , T. Wongjirad , K. Woodruff , T. Yang , L. Yates , G. P. Zeller , J. Zennamo , C. Zhang

The Large Underground Xenon (LUX) dark matter search was a 250-kg active mass dual-phase time projection chamber that operated by detecting light and ionization signals from particles incident on a xenon target. In December 2015, LUX…

We present a detailed study of the spatial resolution of our time-resolved neutron imaging detector utilizing a new neutron position reconstruction method that improves both spatial resolution and event reconstruction efficiency. Our…

An iterative algorithm for reconstructing the photon distribution from the random phase homodyne statistics is discussed. This method, derived from the maximum-likelihood approach, yields a positive definite estimate for the photon…

Quantum Physics · Physics 2007-05-23 Konrad Banaszek

X-ray computed tomography (CT) based on photon counting detectors (PCD) extends standard CT by counting detected photons in multiple energy bins. PCD data can be used to increase the contrast-to-noise ratio (CNR), increase spatial…

Image and Video Processing · Electrical Eng. & Systems 2024-02-05 Natalie M. Jadue , Madhuri Nagare , Jonathan S. Maltz , Gregery T. Buzzard , Charles A. Bouman

This work reports on a new reconstruction algorithm allowing to reconstruct the decays of ortho-positronium atoms into three photons using the places and times of photons recorded in the detector. The method is based on trilateration and…

The LUX dark matter search experiment is a 350 kg dual-phase xenon time projection chamber located at the 4850 ft level of the Sanford Underground Research Facility in Lead, SD. The success of two-phase xenon detectors for dark matter…

Instrumentation and Detectors · Physics 2016-03-23 M. Moongweluwan , for LUX collaboration

High precision vertex and energy reconstruction is crucial for large liquid scintillator detectors such as JUNO, especially for the determination of the neutrino mass ordering by analyzing the energy spectrum of reactor neutrinos. This…

Instrumentation and Detectors · Physics 2022-12-01 Gui-hong Huang , Wei Jiang , Liang-jian Wen , Yi-fang Wang , Wu-Ming Luo

We suggest an iterative, maximum-likelihood-based, method to reconstruct the photon number distribution of the steady state cavity field of a micromaser starting from the statistics of the atoms leaving the cavity after the interaction. The…

Quantum Physics · Physics 2009-11-13 Stefano Olivares , Federico Casagrande , Alfredo Lulli , Matteo G. A. Paris

The Liquid Xenon Gamma-Ray Imaging Telescope (LXeGRIT) is a balloon born experiment sensitive to \g -rays in the energy band of 0.2-20 MeV. The main detector is a time projection chamber filled with high purity liquid xenon (LXeTPC), in…

Astrophysics · Physics 2015-06-24 U. G. Oberlack , E. Aprile , A. Curioni , V. Egorov , K. L. Giboni

We investigate the recovery of structures from large-area, low dose exposures that distribute the dose over many identical copies of an object. The reconstruction is done via a maximum likelihood approach that does neither require to…

Materials Science · Physics 2018-03-28 C. Kramberger , J. C. Meyer

We report results from an extensive set of measurements of the \b{eta}-decay response in liquid xenon.These measurements are derived from high-statistics calibration data from injected sources of both $^{3}$H and $^{14}$C in the LUX…

The cascade mass reconstruction approach was used for mass reconstruction of the lightest stau produced at the LHC in the cascade decay $\tilde{g} \to \tilde{b} b \to \tilde{\chi}_{2}^{0} b b \to \tilde{\tau}_{1} \tau b b \to…

High Energy Physics - Phenomenology · Physics 2011-03-17 Rashid M. Djilkibaev , Rostislav V. Konoplich

Next-generation neutrinoless double beta decay experiments aim for half-life sensitivities of ~$10^{27}$ yr, requiring suppressing backgrounds to <1 count/tonne/yr. For this, any extra background rejection handle, beyond excellent energy…

Instrumentation and Detectors · Physics 2021-09-09 A. Simón , Y. Ifergan , A. B. Redwine , R. Weiss-Babai , L. Arazi , C. Adams , H. Almazán , V. Álvarez , B. Aparicio , A. I. Aranburu , I. J. Arnquist , C. D. R Azevedo , K. Bailey , F. Ballester , J. M. Benlloch-Rodríguez , F. I. G. M. Borges , N. Byrnes , S. Cárcel , J. V. Carrión , S. Cebrián , E. Church , C. A. N. Conde , T. Contreras , F. P. Cossío , A. A. Denisenko , G. Díaz , J. Díaz , J. Escada , R. Esteve , R. Felkai , L. M. P. Fernandes , P. Ferrario , A. L. Ferreira , F. Foss , E. D. C. Freitas , Z. Freixa , J. Generowicz , A. Goldschmidt , J. J. Gómez-Cadenas , R. González , D. González-Díaz , S. Gosh , R. Guenette , R. M. Gutiérrez , J. Haefner , K. Hafidi , J. Hauptman , C. A. O. Henriques , J. A. Hernando Morata , P. Herrero , V. Herrero , J. Ho , B. J. P. Jones , M. Kekic , L. Labarga , A. Laing , P. Lebrun , N. López-March , M. Losada , R. D. P. Mano , J. Martín-Albo , A. Martínez , M. Martínez-Vara , G. Martínez-Lema , A. D. McDonald , Z. -E. Meziani , F. Monrabal , C. M. B. Monteiro , F. J. Mora , J. Muñoz Vidal , C. Newhouse , P. Novella , D. R. Nygren , E. Oblak , M. Odriozola-Gimeno , B. Palmeiro , A. Para , J. Pérez , M. Querol , J. Renner , L. Ripoll , I. Rivilla , Y. Rodríguez García , J. Rodríguez , C. Rogero , L. Rogers , B. Romeo , C. Romo-Luque , F. P. Santos , J. M. F. dos Santos , M. Sorel , C. Stanford , J. M. R. Teixeira , P. Thapa , J. F. Toledo , J. Torrent , A. Usón , J. F. C. A. Veloso , T. T. Vuong , R. Webb , J. T. White , K. Woodruff , N. Yahlali

Proton therapy is an emerging method in cancer therapy. One of the main developments is to increase the accuracy of the Bragg-peak position calculation, which requires more precise relative stopping power (RSP) measurements. A promising…

Medical Physics · Physics 2026-02-18 Gábor Bíró , Ákos Sudár , Zsófia Jólesz , Gábor Papp , Gergely Gábor Barnaföldi
‹ Prev 1 3 4 5 6 7 10 Next ›