English
Related papers

Related papers: Components Qualification for a Possible use in the…

200 papers

The Mu2e calorimeter will employ Readout Units, each made of two Silicon Photomultipliers arrays and two Front End Electronics boards. To calibrate them, we have designed, assembled and put in operation an automated Quality Control (QC)…

Radiation damage on front-end readout and trigger electronics is an important issue in the COMET Phase-I experiment at J-PARC, which plans to search for the neutrinoless transition of a muon to an electron. To produce an intense muon beam,…

The Muon-to-Electron Conversion (Mu2e) Experiment demands a highly precise magnet and collimator system to achieve a stringent extinction level of $1\times 10^{-10}$ for out-of-time beam particles. Extinction is ensured by an AC Dipole…

Accelerator Physics · Physics 2024-05-09 Ryan Hensley , Eric Prebys , Sridhar Tripathy

The CALICE Semi-Digital Hadron Calorimeter technological prototype completed in 2011 is a sampling calorimeter using Glass Resistive Plate Chamber (GRPC) detectors as the active medium. This technology is one of the two options proposed for…

The Mu2e calorimeter is composed of 1400 un-doped CsI crystals, coupled to large area UV extended Silicon Photomultipliers (SiPMs), arranged in two annular disks. This calorimeter has to provide precise information on energy, timing and…

Instrumentation and Detectors · Physics 2017-03-08 S. Baccaro , A. Cemmi , M. Cordelli , E. Diociaiuti , R. Donghia , A. Ferrari , S. Giovannella , S. Miscetti , S. Müller , M. Pillon , I. Sarra

An 805 MHz RF pillbox cavity has been designed and constructed to investigate potential muon beam acceleration and cooling techniques for a Muon Collider or Neutrino Factory. The cavity can operate in vacuum or under pressure to 100…

The Mu2e and COMET experiments are expected to improve existing limits on charged lepton flavor violation (CLFV) by roughly four orders of magnitude. $\mu\rightarrow e$ conversion experiments are typically optimized for electrons produced…

High Energy Physics - Phenomenology · Physics 2025-01-08 W. C. Haxton , Evan Rule

We report on the design and performance of the electromagnetic calorimeter timing readout system (EMTiming) for the Collider Detector at Fermilab (CDF). The system will be used in searches for rare events with high energy photons to verify…

Instrumentation and Detectors · Physics 2008-11-26 M. Goncharov , T. Kamon , V. Khotilovich , V. Krutelyov , S. W. Lee , D. Toback , P. Wagner , H. Frisch , H. Sanders , M. Cordelli , F. Happacher , S. Miscetti , R. Wagner

We explore the possibilities for extending the sensitivity of current searches for the charged lepton flavor violating decays $\mu\ -> e \gamma$ and $\mu\ -> eee$. A future facility such as Project X at Fermilab could provide a much more…

Instrumentation and Detectors · Physics 2013-10-01 Chih-hsiang. Cheng , Bertrand Echenard , David G. Hitlin

Charged lepton flavor violation (CLFV) is expected in a diverse set of new physics scenarios. The current generation of experiments probe CLFV in the muon sector in three complementary channels: $\mu^-N \rightarrow e^- N$ (Mu2e, COMET),…

High Energy Physics - Experiment · Physics 2025-01-28 Sophie Middleton

A sampling calorimeter equipped with gaseous sensor layers with digital readout is near perfect for "Particle Flow Algorithm" approach, since it is homogeneous over large surfaces, robust, cost efficient, easily segmentable to any readout…

Instrumentation and Detectors · Physics 2015-06-19 Y. Haddad , M. Ruan , V. Boudry

In order to fully address the oscillation processes at a neutrino factory, a detector should be capable of identifying and measuring all three charged lepton flavors produced in charged current interactions {\it and} of measuring their…

High Energy Physics - Phenomenology · Physics 2009-10-31 A. Bueno , M. Campanelli , A. Rubbia

Sufficient energy resolution is the key issue for the calorimetry in particle and nuclear physics. The calorimeter of the A4 parity violation experiment at MAMI is a segmented calorimeter where the energy of an event is determined by…

The Muon $g-2$ Experiment at Fermilab uses a gaseous straw tracking detector to make detailed measurements of the stored muon beam profile, which are essential for the experiment to achieve its uncertainty goals. Positrons from muon decays…

Cold electronics is a key technology in many areas of science and technology including space exploration programs and particle physics. A major experiment with a very large number of analog and digital electronics signal processing channels…

Instrumentation and Detectors · Physics 2019-11-26 N. Poonthottathil , F. Krennrich , J. Eisch , A. Weinstein , L. J Bond , D. Barnard , Z. Zhang , L Koester

Recent studies in quantum computing have shown that quantum error correction with large numbers of physical qubits are limited by ionizing radiation from high-energy particles. Depending on the physical setup of the quantum processor, the…

Quantum Physics · Physics 2023-12-11 Ulascan Sarica

The Mu2e experiment at Fermilab will search for the neutrinoless $\mu^- \to e^-$ conversion in the field of an aluminum nucleus. The Mu2e data-taking plan assumes two running periods, Run I and Run II, separated by an approximately…

High Energy Physics - Experiment · Physics 2022-10-21 Mu2e Collaboration

I describe the new generation of muon-to-electron conversion experiments, COMET and Mu2e, being constructed to make use of new high power pulsed muon beams a J-PARC and Fermilab respectively. A brief overview of the physics explored by the…

Instrumentation and Detectors · Physics 2014-12-04 R. P. Litchfield

A compact and fast electromagnetic calorimeter prototype was designed, built, and tested in preparation for a next-generation, high-rate muon g-2 experiment. It uses a simple assembly procedure: alternating layers of 0.5-mm-thick tungsten…

Instrumentation and Detectors · Physics 2009-10-06 R. McNabb , J. Blackburn , J. D. Crnkovic , D. W. Hertzog , B. Kiburg , J. Kunkle , E. Thorsland , D. M. Webber , K. R. Lynch