English
Related papers

Related papers: X-ray luminescence computed tomography using a foc…

200 papers

Biophotonics is an active research area in molecular imaging, genetic diagnosis and prognosis, with direct applicability in precision medicine. However, long-standing challenges of biophotonics are well known due to low signal-to-noise…

Medical Physics · Physics 2017-10-02 Michael C Lun , Wei Zhang , Yue Zhao , Jeffrey Anker , Wenxiang Cong , Ge Wang , Changqing Li

X-ray fluorescence computed tomography (XFCT) is a molecular imaging technique of x-ray photons, which can be used to sense different elements or nanoparticle (NP) agents inside deep samples or tissues. XFCT has been an active research…

Medical Physics · Physics 2021-02-01 Ignacio O. Romero , Yile Fang , Michael Lun , Changqing Li

X-ray fluorescence computed tomography (XFCT), a form of X-ray molecular imaging, offers detailed quantitative imaging capabilities for high-Z metal nanoparticles (MNPs), which are widely studied for their applications in multifunctional…

X-ray luminescence is produced when contrast agents absorb energy from X-ray photons and release a portion of that energy by emitting photons in the visible and near-infrared range. X-ray luminescence computed tomography (XLCT) was…

Image and Video Processing · Electrical Eng. & Systems 2024-06-13 Yile Fang , Yibing Zhang , Changqing Li

X-ray Fluorescence Computed Tomography(XFCT) is a prevalent experimental technique which is utilized to investigate the spatial distribution of elements in sample. The sensitivity of L-shell XFCT of some elements is lower than that of…

Instrumentation and Detectors · Physics 2014-04-30 Liu Long , Huang Yang , Ma Bo , Xu Qing , Yan Lingtong , Li Li , Feng Songlin , Feng Xiangqian

Pencil x-ray beam imaging provides superior spatial resolution than other imaging geometries like sheet beam and cone beam geometries due to the illumination of a line instead of an area or volume. However, the pencil beam geometry suffers…

Medical Physics · Physics 2021-02-01 Ignacio O. Romero , Changqing Li

Due to the merit of establishing volumetric data, X-ray computed tomography (XCT) is increasingly used as a non-destructive evaluation technique in the quality control of advanced manufactured parts with complex non-line-of-sight features.…

The increasingly demand for machining accuracy and product quality excites a great interest in high-resolution non-destructive testing (NDT) methods, but spatial resolution of conventional high-energy computed tomography (CT) is limited to…

We demonstrate computerized tomography (CT) reconstructions from absorption, phase and dark-field signals obtained from scans acquired when the x-ray probe light is modulated with speckle. Two different interlaced schemes are proposed to…

Optics · Physics 2016-04-27 Sebastien Berujon , Eric Ziegler

We previously demonstrated near-field speckle scanning based x-ray imaging to be an easy-to-implement phase sensing method capable of providing both high sensitivity and high resolution. Yet, this performance combination could only be…

Medical Physics · Physics 2017-06-21 Sebastien Berujon , Eric Ziegler

X-ray imaging is a fundamental tool of routine clinical diagnosis. Fluoroscopic imaging can further acquire X-ray images at video frame rates, thus enabling non-invasive in-vivo motion studies of joints, gastrointestinal tract, etc. For…

Image and Video Processing · Electrical Eng. & Systems 2018-10-22 Jacky C. K. Chow , Derek Lichti , Kathleen Ang , Gregor Kuntze , Gulshan Sharma , Janet Ronsky

The number of photons available by coherent X-ray scattering from a single biomolecule is considerably less because of the extremely small elastic-scattering cross-section and low damage threshold. Even with a high X-ray flux of 3 x 10to 12…

Optics · Physics 2009-11-13 Tsumoru Shintake

The image quality of X-ray imaging relies heavily on the X-ray output number which is dependent on the X-ray tube current and the exposure time. Hybrid X-ray imaging modalities like X-ray luminescence CT (XLCT) and X-ray fluorescence CT…

Medical Physics · Physics 2021-10-25 Ignacio O. Romero , Yile Fang , Changqing Li

X-ray dark-field imaging creates a representation of the sample where contrast is generated by subresolution features within the volume under inspection. These are detected by a local measurement of the radiation field's angular…

Due to the energy-dependent nature of the attenuation coefficient and the polychromaticity of the X-ray source, beam hardening effect occurs when X-ray photons penetrate through an object, causing a nonlinear projection data. When a linear…

Medical Physics · Physics 2018-12-07 Wei Zhao , Dengwang Li , Kai Niu , Wenjian Qin , Hao Peng , Tianye Niu

The imaging performance of a high-resolution preclinical microPET system employing liquid xenon as the gamma ray detection medium was simulated. The arrangement comprises a ring of detectors consisting of trapezoidal LXe time projection…

Medical Physics · Physics 2012-03-23 A. Miceli , J. Glister , A. Andreyev , D. Bryman , L. Kurchaninov , P. Lu , A. Muennich , F. Retiere , V. Sossi

Despite advances in low-light level detection, single-photon methods such as photon correlation have rarely been used in the context of imaging. The few demonstrations, for example of sub-diffraction limited imaging utilizing quantum…

Optics · Physics 2017-03-14 Yonatan Israel , Ron Tenne , Dan Oron , Yaron Silberberg

X-Ray based computed tomography (CT) is a well-established technique for determining the three-dimensional structure of an object from its two-dimensional projections. In the past few decades, there have been significant advancements in the…

Medical Physics · Physics 2023-04-26 Dinesh Kumar , Dilworth Y. Parkinson , Jeffrey J. Donatelli

We demonstrate dark-field x-ray microtomography in a compact, laboratory-based system capable of resolving attenuation, phase, and anisotropic scattering signals with micrometer-scale resolution across centimetre-scale samples. The method…

This paper describes the setup of two different solutions for laboratory X-ray microscopy working with geometric magnification. One setup uses thin-film transmission targets with an optimized tungsten-layer thickness and the electron gun…

Instrumentation and Detectors · Physics 2015-06-11 Thomas Ebensperger , Philipp Stahlhut , Frank Nachtrab , Simon Zabler , Randolf Hanke
‹ Prev 1 2 3 10 Next ›