English
Related papers

Related papers: Injection Bucket Jitter Compensation Using Phase L…

200 papers

Efficient simulation of the timing jitter in passively mode-locking lasers is key to their numerical investigation and optimization. We introduce a method based on the pulse-period fluctuation auto-correlation function and compare it…

Optics · Physics 2024-02-22 Stefan Meinecke , Kathy Lüdge

The timing system of SPring-8 booster synchrotron generates various timing signals concerning beam injection, acceleration from 1 GeV to 8 GeV and ejection. We have improved the timing system of the synchrotron giving it better stability…

Accelerator Physics · Physics 2007-05-23 N. Hosoda , T. Ohshima , T. Aoki , T. Asaka , H. Ego , K. Fukami , Y. Kawashima , Y. Ohashi , T. Takashima , H. Yonehara

In fast ramping synchrotrons like the Fermilab Booster the conventional methods of betatron tune evaluation from the turn-by-turn data may not work due to rapid changes of the tunes (sometimes in a course of a few dozens of turns) and a…

Accelerator Physics · Physics 2012-02-08 Y. Alexahin , E. Gianfelice-Wendt , W. Marsh

The distribution system problems, such as planning, loss minimization, and energy restoration, usually involve the phase balancing or network reconfiguration procedures. The determination of an optimal phase balance is, in general, a…

Other Computer Science · Computer Science 2015-03-19 A. Ukil , W. Siti

Fermilab Booster synchrotron requires an intensity upgrade from 4.5x1012 to 6.5x1012 protons per pulse as a part of Fermilabs Proton Improvement Plan-II (PIP-II). One of the factors which may limit the high-intensity performance is the fast…

Accelerator Physics · Physics 2022-08-10 S. A. K. Wijethunga , J. Eldred , C. Y. Tan , E. Pozdeyev

We have developed a computer program interfaced with the ACNET environment of Fermilab accelerators to measure energy spread of the proton beam from the LINAC at an injection into the Booster. It uses a digitizing oscilloscope and provides…

Accelerator Physics · Physics 2017-12-29 J. Nelson , C. M. Bhat , B. S. Hendricks

Radio frequency knock out resonant slow extraction is a standard method for extracting stored particle beams from synchrotrons by transverse excitation. Excitation signals comprising many betatron sidebands have shown to reduce intensity…

Accelerator Physics · Physics 2026-01-30 Philipp Niedermayer , Rahul Singh , Eike Feldmeier , Christian Schömers , Marcel Hun

Fermilab's Recycler ring was used as a storage ring for accumulation and subsequent manipulations of 8-GeV antiprotons destined for the Tevatron collider. To satisfy these missions, a unique electron cooling system was designed, developed…

Accelerator Physics · Physics 2013-01-24 L. R. Prost , A. Shemyakin

The Fermi National Accelerator Laboratory (Fermilab) Linac accepts 750 keV H- ions from the front end and accelerates them to 400 MeV for injection into the Booster rapid cycling synchrotron. Day-to-day drifts in the beam longitudinal…

Accelerator Physics · Physics 2024-07-25 R. Sharankova , A. Shemyakin , S. Rego

This paper shows how the input offset of sampling flip-flops in the Alexander phase detector affects the jitter transfer from data to the recovered clock in a clock data recovery circuit. The Alexander phase detector samples the data at…

Signal Processing · Electrical Eng. & Systems 2020-01-13 Naveen Kadayinti , Maryam Shojaei Baghini , Dinesh K. Sharma

Vibrations of the Jeffcott rotor are modelled by a three degree of freedom system including coupling between lateral and torsional modes. The crack in a rotating shaft of the rotor is introduced via time dependent stiffness with off…

Chaotic Dynamics · Physics 2015-05-13 Grzegorz Litak , Jerzy T. Sawicki

We present the first experimental confirmation of the so-called "self-phaselocked delay interferometry". This laser frequency stabilization technique consists basically in comparing the prompt laser signal with a delayed version of itself…

A new Higher Order Mode (HOM) damper was designed and tested for the Booster accelerator cavity at Fermilab. In anticipation of the PIP-II upgrade, it was discovered that the higher beam intensity of PIP-II may cause beam instability due to…

Accelerator Physics · Physics 2025-09-19 Dustin Pieper , Brian Vaughn , Robyn Madrak

A quiet point, an operating point of pump-resonance detuning that minimizes frequency fluctuation due to nonlinear effects inside a resonator, has been employed for phase noise reduction of a soliton Kerr microresonator frequency comb…

Imperfections in the surface of intracavity elements of an optical ring resonator can scatter light from one mode into the counterpropagating mode. The phase-locking of the cavity modes induced by this backscattering is a well-known example…

Optics · Physics 2009-11-13 G. Krenz , S. Bux , S. Slama , C. Zimmermann , Ph. W. Courteille

We have measured the total energy spread (99 persent energy spread) of the Booster beam at its injection energy of 400 MeV by three different methods - 1) creating a notch of about 40 nsec wide in the beam immediately after multiple turn…

Accelerator Physics · Physics 2015-04-28 C. M. Bhat , B. E. Chase , S. J. Chaurize , F. G. Garcia , K. Seiya , W. A. Pellico , T. M. Sullivan , A. K. Triplett

PIP-II beam transfer line (BTL) to transport the beam from PIP-II Linac to the Booster ring at Fermilab. One crucial aspect of the BTL design involved the implementation of collimators. These collimators play a vital role in removing large…

Accelerator Physics · Physics 2023-12-15 M. Xiao , F. Ostiguy , D. Johnson

Fermilab Booster synchrotron requires an intensity upgrade from 4.5x1012 to 6.5x1012 protons per pulse as a part of Fermilab's Proton Improvement Plan-II (PIP-II). One of the factors which may limit the high-intensity performance is the…

Accelerator Physics · Physics 2023-07-21 S. A. K. Wijethunga , N. Eddy , J. Eldred , C. Y. Tan , B. Fellenz , E. Pozdeyev , R. V. Sharankova

The sensitivity of an atomic interferometer increases when the phase evolution of its quantum superposition state is measured over a longer interrogation interval. In practice, a limit is set by the measurement process, which returns not…

Atomic Physics · Physics 2015-05-05 R. Kohlhaas , A. Bertoldi , E. Cantin , A. Aspect , A. Landragin , P. Bouyer