Related papers: Photoacoustic Imaging using Combination of Eigensp…
The most common technique for generating B-mode ultrasound (US) images is delay and sum (DAS) beamforming, where the signals received at the transducer array are sampled before an appropriate delay is applied. This necessitates sampling…
Optical resolution photoacoustic microscopy (OR-PAM) leverages optical focusing and acoustic detection for microscopic optical absorption imaging. Intrinsically it owns high optical lateral resolution and poor acoustic axial resolution.…
In recent years, the minimum variance (MV) beamforming has been widely studied due to its high resolution and contrast in B-mode Ultrasound imaging (USI). However, the performance of the MV beamformer is degraded at the presence of noise,…
This work presents a comparison of the delay and sum (DAS), filtered delay multiply and sum (DMAS), minimum variance (MV) and specular receive beamforming schemes in the context of ultrasound imaging of specular reflectors. The main…
Photoacoustic microscopy (PAM) is an emerging imaging method combining light and sound. However, limited by the laser's repetition rate, state-of-the-art high-speed PAM technology often sacrifices spatial sampling density (i.e.,…
Conventional ultrasound (US) imaging employs the delay and sum (DAS) receive beamforming with dynamic receive focus for image reconstruction due to its simplicity and robustness. However, the DAS beamforming follows a geometrical method of…
Beamforming in ultrasound imaging has significant impact on the quality of the final image, controlling its resolution and contrast. Despite its low spatial resolution and contrast, delay-and-sum is still extensively used nowadays in…
Photoacoustic imaging (PAI) suffers from inherent limitations that can degrade the quality of reconstructed results, such as noise, artifacts and incomplete data acquisition caused by sparse sampling or partial array detection. In this…
In ultrasound (US) imaging, individual channel RF measurements are back-propagated and accumulated to form an image after applying specific delays. While this time reversal is usually implemented using a hardware- or software-based…
The standard technique used by commercial medical ultrasound systems to form B-mode images is delay and sum (DAS) beamforming. However, DAS often results in limited image resolution and contrast, which are governed by the center frequency…
Background: Photoacoustic Microscopy (PAM) integrates optical and acoustic imaging, offering enhanced penetration depth for detecting optical-absorbing components in tissues. Nonetheless, challenges arise in scanning large areas with high…
Recent advances in generative models, especially diffusion models, have significantly improved image restoration (IR) performance. However, existing problem-agnostic diffusion model-based image restoration (DMIR) methods face challenges in…
One primary technical challenge in photoacoustic microscopy (PAM) is the necessary compromise between spatial resolution and imaging speed. In this study, we propose a novel application of deep learning principles to reconstruct…
While supervised stereo matching and monocular depth estimation have advanced significantly with learning-based algorithms, self-supervised methods using stereo images as supervision signals have received relatively less focus and require…
Photoacoustic microscopy holds the potential to measure biomarkers' structural and functional status without labels, which significantly aids in comprehending pathophysiological conditions in biomedical research. However, conventional…
Ultrasound (US) imaging is based on the time-reversal principle, in which individual channel RF measurements are back-propagated and accumulated to form an image after applying specific delays. While this time reversal is usually…
Image Phase Alignment Super-sampling (ImPASS) is a computational method for combining displaced low-resolution images into a single high-resolution image. The general steps include measuring the relative displacements, up-sampling, aligning…
We present the first application of the extended Fast Action Minimization method (eFAM) to a real dataset, the SDSS-DR12 Combined Sample, to reconstruct galaxies orbits back-in-time, their two-point correlation function (2PCF) in…
Diffusion models (DMs) have exhibited remarkable efficacy in various image restoration tasks. However, existing approaches typically operate within the high-dimensional pixel space, resulting in high computational overhead. While methods…
Photoacoustic microscopy (PAM) is a novel implementation of photoacoustic imaging (PAI) for visualizing the 3D bio-structure, which is realized by raster scanning of the tissue. However, as three involved critical imaging parameters,…