Related papers: Recent X-ray hybrid CMOS detector developments and…
X-ray Hybrid CMOS Detectors (HCDs) have advantages over X-ray CCDs due to their higher readout rate abilities, flexible readout, inherent radiation hardness, and low power, which make them more suitable for the next generation large area…
We present preliminary characterization of the Speedster-EXD, a new event driven hybrid CMOS detector (HCD) developed in collaboration with Penn State University and Teledyne Imaging Systems. HCDs have advantages over CCDs including lower…
Future space-based X-ray telescope missions are likely to have significantly increased demands on detector read out rates due to increased collection area, and there will be a desire to minimize radiation damage in the interests of…
The development of Hybrid CMOS Detectors (HCDs) for X-Ray telescope focal planes will place them in con- tention with CCDs on future satellite missions due to their faster frame rates, flexible readout scenarios, lower power consumption,…
X-ray hybrid CMOS detectors (HCDs) are a promising candidate for future x-ray missions requiring high throughput and fine angular resolution along with large field-of-view, such as the high-definition x-ray imager (HDXI) instrument on the…
The Speedster-EXD is a new 64x64 pixel, 40 $\mu$m pixel pitch, 100 $\mu$m depletion depth hybrid CMOS X-ray detector (HCD) with the capability of reading out only those pixels containing event charge, thus enabling fast effective frame…
Future x-ray observatories will require imaging detectors with fast readout speeds that simultaneously achieve or exceed the other high performance parameters of x-ray charge-coupled devices (CCDs) used in many missions over the past three…
The broad energy response, low electronic read noise, and good energy resolution have made X-ray Charge-Coupled Devices (CCDs) an obvious choice for developing soft X-ray astronomical instruments over the last half century. They also come…
Hybrid CMOS detectors (HCDs) have several excellent features as high-performance X-ray detectors, including rapid readout, deep-depletion silicon for high quantum efficiency, radiation hardness, and low power. Random telegraph noise (RTN)…
Next-generation X-ray observatories, such as the Lynx X-ray Observatory Mission Concept or other similar concepts in the coming decade, will require detectors with high quantum efficiency (QE) across the soft X-ray band to observe the faint…
We report on the characterization of four Teledyne Imaging Systems HAWAII Hybrid Si CMOS detectors designed for X-ray detection. Three H1RG detectors were studied along with a specially configured H2RG. Read noise measurements were…
AXIS, a Probe mission concept now in a Phase A study, will provide transformative studies of high-energy astrophysical phenomena thanks to its high-resolution X-ray spectral imaging. These capabilities are enabled by improvements to the…
Next-generation X-ray observatories, such as the Lynx X-ray Observatory Mission Concept, will require detectors with high quantum efficiency (QE) across the soft X-ray band to observe the faint objects that drive their mission science…
X-ray Charge Coupled Devices (CCDs) have been the workhorse for soft X-ray astronomical instruments for the past quarter century. They provide broad energy response, extremely low electronic read noise, and good energy resolution in soft…
The upcoming SCALES (Slicer Combined with Array of Lenslets for Exoplanet Spectroscopy) instrument for W.M. Keck Observatory will enable new imaging and low-/mid-resolution coronagraphic integral field spectroscopic observations over the…
Current, state-of-the-art CCDs are close to being able to deliver all key performance figures for future strategic X-ray missions except for the required frame rates. Our Stanford group is seeking to close this technology gap through a…
AXIS is a Probe-class mission concept that will provide high-throughput, high-spatial-resolution X-ray spectral imaging, enabling transformative studies of high-energy astrophysical phenomena. To take advantage of the advanced optics and…
Future strategic X-ray missions, such as the Advanced X-ray Imaging Satellite (AXIS) and those targeted by the Great Observatories Maturation Program (GOMaP), require fast, low-noise X-ray imaging spectrometers. To achieve the speed and…
We have developed a silicon pixel detector to enhance the physics capabilities of the PHENIX experiment. This detector, consisting of two layers of sensors, will be installed around the beam pipe at the collision point and covers a…
When an X-ray is incident onto the silicon absorber array of a detector, it liberates a large number of electrons, which tend to diffuse outward into what is referred to as the charge cloud. This number can vary from tens to thousands…