English
Related papers

Related papers: A modular, extendible and field-tolerant multichan…

200 papers

The magnetic field noise in superconducting quantum interference devices (SQUIDs) used for biomagnetic research such as magnetoencephalography or ultra-low-field nuclear magnetic resonance is usually limited by instrumental dewar noise. We…

Instrumentation and Detectors · Physics 2017-02-20 Jan-Hendrik Storm , Peter Hömmen , Dietmar Drung , Rainer Körber

We report on the development of an ultralow noise thin-film based SQUID magnetometer. A niobium thin-film pickup coil is connected to the input coil of a SQUID current sensor. The low capacitance of the used sub-micrometer cross-type…

Instrumentation and Detectors · Physics 2017-05-18 M. Schmelz , V. Zakosarenko , A. Chwala , T. Schönau , R. Stolz , S. Anders , S. Linzen , H. -G. Meyer

The requirements for the construction of ultra-sensitive SQUID instrumentation as used in biomagnetism are presented. Typically, SQUIDs are inductively coupled to pick-up coils and for this arrangement one can improve the noise performance…

Instrumentation and Detectors · Physics 2019-03-25 Rainer Körber

There is currently fundamental and technological interest in measuring and manipulating nanoscale magnets, particularly in the quantum coherent regime. To observe the dynamics of such systems one requires a magnetometer with not only…

Mesoscale and Nanoscale Physics · Physics 2015-05-18 M. Hatridge , R. Vijay , D. H. Slichter , J. Clarke , I. Siddiqi

Here we present a multichannel system based on superconducting quantum interference devices (SQUIDs) for magnetoencephalography (MEG) measurements, developed and installed at Istituto di Cibernetica (ICIB) in Naples. This MEG system,…

Medical Physics · Physics 2013-10-18 S Rombetto , C Granata , A Vettoliere , A Trebeschi , R Rossi , M Russo

We designed and fabricated a new type of superconducting quantum interference device (SQUID) susceptometers for magnetic imaging of quantum materials. The 2-junction SQUID sensors employ 3D Nb nano-bridges fabricated using electron beam…

Mesoscale and Nanoscale Physics · Physics 2019-05-22 Y. P. Pan , S. Y. Wang , X. Y. Liu , Y. S. Lin , L. X. Ma , Y. Feng , Z. Wang , L. Chen , Y. H. Wang

We describe a dispersive nanoSQUID magnetometer comprised of two variable thickness aluminum weak-link Josephson junctions shunted in parallel with an on-chip capacitor. This arrangement forms a nonlinear oscillator with a tunable 4-8 GHz…

Mesoscale and Nanoscale Physics · Physics 2013-04-16 E. M. Levenson-Falk , R. Vijay , N. Antler , I. Siddiqi

A seven-channel system capable of performing both magnetoencephalography (MEG) and ultra-low-field magnetic resonance imaging (ULF MRI) is described. The system consists of seven second-order SQUID gradiometers with 37 mm diameter and 60 mm…

Magnetic resonance imaging at ultra-low fields (ULF MRI) is a promising new imaging method that uses SQUID sensors to measure the spatially encoded precession of pre-polarized nuclear spin populations at a microtesla-range measurement…

Medical Physics · Physics 2007-10-18 V. S. Zotev , A. N. Matlashov , P. L. Volegov , A. V. Urbaitis , M. A. Espy , R. H. Kraus

We have developed a novel dc SQUID system with a micro-coil input circuit to act as a local probe of quantum matter and nanosystems. The planar niobium micro-coil pickup loop is located remotely from the SQUID, coupled through a…

The magnetic sensing at nanoscale level is a promising and interesting research topic of nanoscience. Indeed, magnetic imaging is a powerful tool for probing biological, chemical and physical systems. The study of small spin cluster, like…

Superconductivity · Physics 2016-01-12 Carmine Granata , Antonio Vettoliere

Superconducting quantum interference devices (SQUIDs) are among the most sensitive detectors for out-of-plane magnetic field components. However, due to their periodic response with short modulation period $M = 1 \Phi_0$, determined by the…

We investigated, at temperature $4.2\,\mathrm{K}$, electric transport, flux noise and resulting spin sensitivity of miniaturized Nb direct current superconducting quantum interference devices (SQUIDs) based on submicron Josephson junctions…

Superconductivity · Physics 2015-05-28 J. Nagel , O. F. Kieler , T. Weimann , R. Wölbing , J. Kohlmann , A. B. Zorin , R. Kleiner , D. Koelle , M. Kemmler

Direct-current superconducting quantum interference devices (dc-SQUIDs) are one of the most sensitive magnetic detectors. These sensors are extensively used in the readout of superconducting transition edge sensors (TESs), which are used…

Instrumentation and Detectors · Physics 2026-01-29 Nan Li , Mengjie Song , Sixiao Hu , Wentao Wu , Songqing Liu , Tangchong Kuang , Yudong Gu , Xiangxiang Ren , Xufang Li , He Gao , Zhengwei Li , Congzhan Liu

We have fabricated arrays of High-T$_c$ Superconducting Quantum Interference Devices (SQUIDs) with randomly distributed loop sizes as sensitive antennas for Radio-Frequency (RF) waves. These sub-wavelength size devices known as…

Miniaturization of superconducting quantum interference devices (SQUIDs) is of major importance for the development of sensitive scanning nanoscale magnetometry tools. The high sensitivity of nanoSQUIDs is restricted, however, to only…

Superconductivity · Physics 2016-11-28 Alexander Y. Meltzer , Aviram Uri , Eli Zeldov

Superconducting quantum interference devices (SQUIDs) are exceptionally sensitive magnetometers capable of detecting weak magnetic fields. Miniaturizing these devices and integrating them onto scanning probes enables high-resolution imaging…

Parallel imaging techniques have been widely used in high-field magnetic resonance imaging (MRI). Multiple receiver coils have been shown to improve image quality and allow accelerated image acquisition. Magnetic resonance imaging at…

Medical Physics · Physics 2008-11-26 V. S. Zotev , P. L. Volegov , A. N. Matlashov , M. A. Espy , J. C. Mosher , R. H. Kraus

We report on a scanned superconducting quantum interference device (SQUID) microscope operating in a cryogen-free cryostat, with the capability of up to forty RF connections with 20 GHz bandwidth to a device under test. The system utilizes…

Superconductivity · Physics 2025-09-10 Ian W. Haygood , Bochao Xu , John Biesecker , Michael L. Schneider

We developed a scanning DC SQUID microscope with novel readout electronics capable of wideband sensing RF magnetic fields from 50 to 200 MHz and simultaneously providing closed-loop response at kHz frequencies. To overcome the 20 MHz…

‹ Prev 1 2 3 10 Next ›